7. OPERATION OF THE SYSTEM
After pressing the RESET button, during reset, the display screen first
shows all the lit-up digits and then all the digits that are not lit up.
At the end of the process, a display page is first shown with the Reset
Partial and the Reset Total.
After a few moments, the Reset Total is replaced by the NON resettable.
C2. RESETTING THE RESET TOTAL
The Reset Total resetting operation can only be performed after resetting
the Partial register. The Reset Total can in fact be reset by pressing the
RESET button at length while the display screen shows "Reset Total" as
on the following display page:
Schematically, the steps to be taken are:
1. Wait for the display to show normal standby display page (with Total
only displayed).
2. Press the RESET button quickly.
3. The meter starts to Reset Partial.
4. While the display page showing the Reset Total is displayed, press the
RESET button again for at least 1 second.
5. The display screen again shows all the segments of the display
followed by all the switched-off segments. Finally it shows the display
page where the reset total is shown.
C3. DISPENSING WITH THE FLOW RATE MODE DISPLAY
It is possible to dispense fluids, displaying at the same time:
•The dispensed Partial
•The flow rate in [Partial Unit / minute] as shown on the following
display page:
Procedure for entering this mode:
1. Wait for the Remote Display to go to Standby, meaning the display
screen shows "Total only"
2. Quickly press the CAL button.
3. Start dispensing
The flow rate is updated every 0.7 seconds. Consequently, the display
could be relatively unstable at lower flow rates. The higher the flow rate,
the more stable the displayed value.
WARNING
The flow rate is measured with reference to the unit of measurement
of the Partial. For this reason, in case of the unit of measurement of
the Partial and Total being different, as in the example shown below,
remember that the indicated flow rate relates to the unit of measurement
of the partial. In the example shown, the flow rate is expressed in Qts/
min.
The word "Gal" remaining alongside the flow rate refers to the register of
the Totals (Reset or NON Reset) which are again displayed when exiting
from the flow rate reading mode.
To return to "Normal" mode, press the CAL button again. If one of the two
buttons RESET or CAL is accidentally pressed during the count, this will
have no effect.
WARNING
Even though in this mode they are not displayed, both the Reset Total
and the General Total (Total) increase. Their value can be checked after
dispensing has terminated, by returning to "Normal" mode, and quickly
pressing CAL.
C4. PARTIAL RESET
To reset the Partial Register, finish dispensing and wait for the Remote
Display to show a Flow Rate of 0.0 as
indicated in the illustration then quickly press RESET
D1. CONFIGURATION
Use the menu in the Remote Display to configure the machine in
accordance with their requirements.The configuration menu consists of
two submenus:
1. Configuration menu for the main unit of measurement
2. Configuration menu for the number of impulses per unit of
measurement that the machine can receive on the Pulse-In inlet.
24