Systema KING Instruction Manual

Airtight gas convectors
Table of Contents

Advertisement

Quick Links

AIRTIGHT GAS CONVECTORS
Pilot flame thermocouple series, natural balanced mod. KING 21
Ventilated/forced circulation series mod. KING 30 FE, KING 50 FE,
Instruction manual
"Installation, use and maintenance"
ENGLISH
KING
KING 70 FE
14GBEN08062020
01IT1810
Rev. 14GBEN08062020

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KING and is the answer not in the manual?

Questions and answers

Summary of Contents for Systema KING

  • Page 1 KING AIRTIGHT GAS CONVECTORS Pilot flame thermocouple series, natural balanced mod. KING 21 Ventilated/forced circulation series mod. KING 30 FE, KING 50 FE, KING 70 FE Instruction manual “Installation, use and maintenance” ENGLISH 14GBEN08062020 01IT1810 Rev. 14GBEN08062020...
  • Page 2 Before installation, check that the local conditions of distribution, the nature of the gas and of the pressure are compatible with the setting of the appliance. In order to improve the product, Systema reserves the right to modify its contents as required and without warning.
  • Page 3: Table Of Contents

    INSTALLATION OF THE KING 30 FE-50 FE WITH STANDARD AIR/FUME KIT .............28 INSTALLATION OF KING 30 FE-50 FE WITH "FLUSH WITH THE WALL" AIR/FUME KIT ..............29 5.4.1 Installation of King with side wall exhaust pipe for KING 30 FE, KING 50 FE ..............30 MESSA IN OPERA KING 70 FE ............................32 GAS PIPING ..................................34...
  • Page 4 SUMMARY RESPONSIBILITY ................................43 JUDICIAL DISPUTES - TERRITORIAL COMPETENCE AND POWERS OF THE PARTIES ...........43 STORAGE AND DISPOSAL ............................. 44 STORAGE ..................................44 DISPOSAL ..................................44 SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 5: General Rules

    In the event of a change of owner or a new renter, submit all the documentation relating to the heating system to the new owner/renter. KING appliances are conceived for the heating of small rooms, exploiting the principle of forced convection, the device ■...
  • Page 6 ■ It is forbidden to place containers with water on top of the appliance. ■ It is forbidden to use the appliance to place wet clothes to dry. SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 7 GENERAL RULES King appliances must not be powered by fuel containing carbon monoxide or other toxic components. ■ It is absolutely forbidden to fill the humidifier cup with water (see pic. 3.7 and 3.8 pages 20-21) when it is in its position inside the ■...
  • Page 8: Terminology Used In The Manual

    Physical injury, or damage to the health of persons or the deterioration of property or of the environment. Electrocution Electric discharge to which the human body is subjected by an operator who comes into contact with a part under elec- trical voltage. User An individual or organisation that uses the devices. SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 9: Packaging

    The air / flue gas terminals and the mask are delivered packed in a carton. ATTENTION Perform the unpacking operation with the aid of appropriate equipment and/or protections according to current legislation, and use appropriate equipments. GAS CONVECTORS FLUE GAS-AIR KIT (See paragraph 3.11) Fig. 2.1 Package contents SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 10: Storage

    In case of lifting of loads of less than 25 kg by a single operator, it is advisable to bend the knees and apply strength on the legs: during transport, keep the load close to the body while keeping the spine erect. Fig. 2.2 SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 11: General Technical Characteristics

    Nozzle diameter Max nominal consumption Electrical Power Supply X/XX XXX/XX Degree of protection Electrical Power X XXX Class Regulated for XXXXXXXXXXXX Fig. 3.1 Important The position of the product identification data-plate may change depending on the model (fig.3.1) SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 12: Information Labels

    Sull’imballo del generatore sono applicate alcune etichette di informazioni (fig. 3.2). All’interno dell'imbalaggio, assieme al manuale di istruzioni, sono presenti le etichette da utilizzare per il cam- bio di combustibile (fig. 3.3). Fig. 3.2 Fig. 3.3 SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 13: Device Classification

    1266: 2002 + A1: 2005 (forced flow). Device type: C (King 21), C (King 30 FE e King 50 FE) and C (King 70 FE) depending on the flue gas suction and expulsion system used. Device output class: 1 DESCRIPTION AND OPERATIONAL CHARACTERISTICS...
  • Page 14 Starting time ............... < 10 s Switch off time ..............< 60 s SOLENOID GAS VALVE TECHNICAL DATA T 840 Sigma: KING 30 FE; KING 50 FE; KING 70 FE Gas connections ..............RP 1/2 F ISO 7 Power supply voltage ............230 VAC 50/60 Hz Electrical protection rating ..........
  • Page 15: Technical Data

    TECHNICAL DATA Balanced flow pilot Forced flow electrononic series models flame series models NATURAL FORCED FLOW AND VENTILATED CONVECTION Models KING 21 KING 30 FE KING 50 FE KING 70 FE Category , II 2H3B/P 2H3P Rated heat flow Working heat output...
  • Page 16: Informazioni Obbligatorie Secondo Regolamento (Ue) 2015/1188 - Direttiva 2009/125/Ce

    CHARACTERISTICS 3.5.1 Informazioni obbligatorie secondo Regolamento (UE) 2015/1188 - DIRETTIVA 2009/125/ KING KING KING 30 FE KING KING 50 FE KING KING 70 FE Model identification 30 FE (with timer) 50 FE (con timer) 70 FE (with timer) Indirect heating functionality Direct thermal power...
  • Page 17: Overall Dimensions King 21, 30 Fe, 50 Fe

    Fig. 3.4 IMPORTANT: the KING gas convector must be installed at 10 cm minimum distance from the ground; it is necessary to forsee the space for the gas interception. The hole for the gas pipe has to be provided under the appliance, between the appliance and the ground, according to the gas inlet of the appliance itself.
  • Page 18: Overall Dimensions King 70 Fe

    ASSEMBLY FRAME (front view) Fig. 3.5 IMPORTANT: the KING gas convector must be installed at 10 cm minimum distance from the ground; it is necessary to forsee the space for the gas interception. The hole for the gas pipe has to be provided under the appliance, between the appliance and the ground, according to the gas inlet of the appliance itself.
  • Page 19: Exploded View King 21

    CHARACTERISTICS EXPLODED VIEW KING 21 Fig. 3.6 Exploded view mod. KING 21 KING 21 PILOT FLAME TYPE THERMOCOUPLE SERIES CONVECTOR Pos. Q.ty Description Code Shell 02MACO0028 Door 02CNPO0304 Cast iron casting with burner Various Eurosit pilot flame valve 02CNVE0679 Air box 02CNSA0378 Tab. 3.5 SYSTEMA S.P.A.
  • Page 20: Exploded View King 30 Fe

    Elec- trocution warning, disconnect the power supply before carrying out the operation and fill the glass only up to 3-4 cm from the edge. Fig. 3.7 Exploded view mod. KING 30 FE KING 30 FE VENTILATED/FORCED CIRCULATION SERIES Pos. Q.ty...
  • Page 21: Exploded View King 50 Fe

    Elec- trocution warning, disconnect the power supply before carrying out the operation and fill the glass only up to 3-4 cm from the edge. Fig. 3.8 Exploded view mod. KING 50 FE KING 50 FE VENTILATED/FORCED CIRCULATION SERIES Pos. Q.ty...
  • Page 22: Exploded View King 70 Fe

    CHARACTERISTICS 3.11 EXPLODED VIEW KING 70 FE Fig. 3.9 Exploded view mod. KING 70 FE KING 70 FE SERIE ELETTRONICA FORZATO Pos. Q.ty Description Code Pos. Q.ty Description Code Shell 02CVMA4024 Fume suction connection 02CNCO1116 Door 02CNPO0302 Stainless steel exchanger...
  • Page 23: Flue Systems

    3.12.1 Air/fume kit for King 21 For installation see paragraph 5.2 Fig. 3.10 3.12.2 Air/fume kit for King 30 FE and King 50 FE For installation see paragraph 5.3 and 5.4 Fig. 3.11 Standard Fig. 3.12 Flush with the wall 3.12.3 Air/fume kit for King 70 FE...
  • Page 24: Electric Diagram

    RST Reset button Operation signal (green) Tab. 4.1 Electrical Fig. 4.1 power supply 230VAC - 50Hz Electric diagram KING 30 FE - KING 50 FE with timer SIT 579 DBC Electrical Fig. 4.2 power supply 230VAC - 50Hz SYSTEMA S.P.A.
  • Page 25 Block signal (red) RST Reset button Operation signal (green) Electrical Tab. 4.2 Fig. 4.3 power supply 230VAC - 50Hz Electric diagram KING 70 FE with timer SIT 579 DBC Electrical Fig. 4.4 power supply 230VAC - 50Hz SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 26: Instructions For Installers

    10 cm higher; c. A minimum distance of 10 cm from the wall must be respected whenever devices are installed in recessed niches. ■ Avoid positioning furnishings above the shell. Fig. 5.1 SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 27: Installation Of The King 21 Air/Fume Kit

    INSTALLATION INSTALLATION OF THE KING 21 AIR/FUME KIT For the assembling of the appliance, please follow the instruction given in the following pages: 1. Place the template on the wall and fix it with ad- Fig. 5.2 hesive tape at a distance of minimum 10 cm from the floor perfectly in square (see fig 5.2).
  • Page 28: Installation Of The King 30 Fe-50 Fe With Standard Air/Fume Kit

    INSTALLATION INSTALLATION OF THE KING 30 FE-50 FE WITH STANDARD AIR/FUME KIT For the assembling of the appliance, please follow the instruction given in the following pages: 1. Place the template on the wall and fix it with ad- Fig. 5.6 hesive tape at a distance of minimum 10 cm from the floor perfectly in square (see fig.
  • Page 29: Installation Of King 30 Fe-50 Fe With "Flush With The Wall" Air/Fume Kit

    INSTALLATION INSTALLATION OF KING 30 FE-50 FE WITH "FLUSH WITH THE WALL" AIR/ FUME KIT For the assembling of the appliance, please follow Fig. 5.10 the instruction given in the following pages: 1. Place the template on the wall and fix it with ad- hesive tape at a distance of minimum 10 cm from the floor perfectly in square (see fig.
  • Page 30: Installation Of King With Side Wall Exhaust Pipe For King 30 Fe, King 50 Fe

    INSTALLATION 5.4.1 Installation of King with side wall exhaust pipe for KING 30 FE, KING 50 FE For assembly follow the instructions below: 1. Drill (Ø60) the wall following the instructions at A and B measures (see drawing 29) 2. Fix on the wall the back connector for the side...
  • Page 31 SIDE FUME KIT WALL HOLE Ø 60mm GROUND Fig. 5.16 Front view IMPORTANT For the positioning of the air-flue gas terminal, refer to the national and local regulations in force. (In Italy, see UNI 7129-3: 2015 standard). SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 32: Messa In Opera King 70 Fe

    INSTALLATION MESSA IN OPERA KING 70 FE Observe the instructions provided in the following pages for the assembly of the device: 1. Position the assembly frame on the wall and fas- ten it using sticky tape at a minimum distance of 10 cm from the floor perfectly squared (See fig.
  • Page 33 1 meter length terminal. IMPORTANT: The device must be prearranged at the factory, according to the of device. 10cm Fix with self-drilling screws Fig. 5.22 Example of side wall installation with coaxial Air/Fume kit SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 34: Gas Piping

    9 (fig. 5.23) for pilot flame device (KING 21), while for electronic devices (KING 30 FE; KING 50 FE; KING 70 FE), turn completely the pressure adjuster 3 (fig. 5.23). To check the inlet pressure use the check point placed (point 5 fig. 5.23 and point 2 fig. 5.54) above the valve inlet gas connector (with burner running).
  • Page 35: Pilot Flame Gas Valve For King 21

    INSTALLATION 5.6.1 Pilot flame gas valve for King 21 LEGEND Control dial Pilot frame adjustment screw Minimum flow adjustment screw Outlet pressure tap (at nozzle) Inlet pressure tap (from mains) Pilot flame supply line pipe Thermocouple Magnet unit Pressure regulator - stabilizer Gas inlet connector thread Main burner supply line pipe...
  • Page 36: Regulation Of Pilot Flame Gas Valve

    10. At the end of regulations, put again the plastic cover onto the valve. Fig. 5.24 Pilot flame gas valve for King K21 11. Disabling the pressure regulator 12. Using a screwdriver take out the plastic cover of the valve.
  • Page 37: Solenoid Gas Valve "Electronic" Type For King 30 Fe, King 50 Fe, King 70 Fe

    INSTALLATION 5.6.3 Solenoid gas valve “ ” type for King 30 FE, King 50 FE, King 70 FE ELECTRONIC LEGEND Outlet pressure tap (at nozzle) Inlet pressure tap (from mains) Pressure regulator - stabilizer Main burner supply line pipe Sealing connector Nozzle-holder sleeve Nozzle Brass closing plug Tab.
  • Page 38: Starting And Operation Of Pilot Flame Devices King 21

    INSTALLATION STARTING AND OPERATION OF PILOT FLAME DEVICES KING 21 1. Set the dial (1) in the position (¬) on the index (See fig. 5.23). 2. Press the dial (1) and keep it pressed down for approx. 10 seconds. 3. Press the piezoelectric button (12) to light the burner’s pilot flame.
  • Page 39: Malfunctions And Solutions

    The anti-wind grille has been clogged. d) Clean the grille. Tab. 5.5 5.12.2 Malfunctions and solutions for electronic devices King 30 FE; King 50 FE DEFECTS: The “red” block light switches on. CAUSES SOLUTIONS a) There is no gas or the pressure is too high.
  • Page 40: 5.12.3 Malfunctions And Solutions For Electronic Devices King 70 Fe

    Obstructed terminal d) Clean the terminal Tab. 5.8 5.12.3 Malfunctions and solutions for electronic devices King 70 FE DEFECTS: The “red” block light switches on. CAUSES SOLUTIONS a) There is no gas or the pressure is too high.
  • Page 41: Maintenance

    WARNING Transformation must be performed only by qualified professionals in complete respect of the safety regulations in force. The Manufacturer declines all liability for erroneous transformation or the inappropriate or incorrect use of the device. SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 42: Warranty

    - and/or the rules of good technique; - damage caused by accidents, fire, accidents in general or negligence not attributable to SYSTEMA. Manoeuvres or failures due to interventions of unauthorised personnel. Faults caused by anomalies dependent on the power or fuel supply.
  • Page 43: Competences

    Jurisdiction of the Court of Padua is established, even in the case of an action for connection or warranty claim. Pending proceedings do not exempt the customer from payment obligations, which must follow their contractual course, until the final decision of the Judicial Authority. SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 44 All operations must be carried by qualified personnel with the appropriate skills and in compli- ance with the national and local regulations in force. WARNING During operations, use safety gloves, harness, cap, and footwear for maintenance operations according to the effective regulations. SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 45 If the piping is not dismantled, seal the terminals where the appliances were connected with threaded caps. SYSTEMA S.P.A. KING rev. 14GBEN08062020...
  • Page 46 SYSTEMA S.p.A. Via Antonio Ceccon, 3 - Loreggia C.A.P. 35010 PADOVA - ITALIA Tel. +39.049.9355663 multiple lines - export@systema.it www.systema.it In order to improve the quality of its products, Systema S.p.A. reserves the right to modify its features with- out prior notice.

This manual is also suitable for:

King 21King 30 feKing 50 feKing 70 fe

Table of Contents