Operating instructions
No.: HDP 502 / S 1100-50
Page 56, Issue: 03.2017
Pos : 86 /Instandhaltung/Pumpen/Austaus ch Berstsc heibe bis 1500 bar ab 03.2011 @ 6\mod_1299838371271_2.doc x @ 45089 @ 3 @ 1
11.5.1 Replacing the rupture disc up to 1500 bar operating pressure
When the burst disc is destroyed, unscrew the high pressure line from the connection piece (40) and then:
Fit a spanner SW 36 onto the connection piece (10).
Unscrew the connection piece (40) with a spanner SW 27 and pull it completely out with the plug (30) and the
rupture disc (50). Grease the outer thread of the connection piece (40) carefully with Molykote1000 (order no.
04.02750.0011)
Position the plug (30) on the end of the connection piece (40). Use grease Stabyl MO 500 (order No.
04.04660.0002) to fix the plug there.
Grease the rupture disc (50) with Stabyl MO 500 and place it onto the plug (30).
Screw connection piece (40) together with plug and disc into the connection piece (10) and tighten up
with 110 Nm.
Grease the outer thread of the high pressure line with Molykote1000 and connect it with the connection piece
again.
Pos : 87 /xxxxxxxxx xxxxxx xxxx @ 0\mod6_2.doc x @ 1188 @ @ 1
Maintenance
Item no.
Description
10
Connection piece
20
Seal ring
30
Plug
40
Connection piece
50
Rupture disc
Copyright Hammelmann GmbH
Germany D-59302 Oelde Carl-Zeiss-Straße 6 - 8
Need help?
Do you have a question about the HDP 502 / S 1100-50 and is the answer not in the manual?
Questions and answers