ASSEMBLY
Reinstallation is the reverse of the above steps:
•
UV lamp – Do not touch with bare hands . If touched, clean the bulb with a cotton swab
and a small amount of alcohol .
Attach ActivePure® Target Screen (a) to the Target Frames (b) .
•
Install the legs of the Target Frames (b) into the four holes of the Bulb Assembly PC
•
board (c) .
Attach the 3‐pin connector (e) of the Bulb Assembly to the main unit PC board .
•
Carefully align the two holes in the Bulb Assembly to the two tabs on the main unit .
•
Press gently to install the Bulb Assembly .
•
Carefully replace the bottom case, being sure the pins inside the back of the bottom
•
case fit into the two standoffs at back of the top case . Slide the bottom case forward
then down, making sure the wires are completely inside the case .
Check for proper alignment before installing and tightening the screws . Failure to
•
correctly assemble may cause damage to the case .
•
Replace cover and two screws .
MAINTENANCE
A service kit is available for your Air Scrubber Mobile by Aerus . The kit contains a new ActivePure® Target, UV bulb, and ActivePure®
Purification Plate . For optimum performance, we recommend replacing these components annually . See your Independent HVAC
Contractor for more information .
CLEANING
Depending on conditions, your Air Scrubber Mobile by Aerus will require periodic cleaning of certain internal components every one to three months .
ActivePure® Target - Clean the target by gently removing dust with a small, soft brush .
UV Bulb - The UV bulb should be gently wiped with a soft, dry cloth . Avoid handling the UV bulb more than necessary .
ActivePure® Ozone Plate - The top area of the ActivePure® Purification Plate can be cleaned with ammonia or alcohol and a cotton swab . Do not use water . Allow to
dry thoroughly .
Case - Clean the exterior case of your Air Scrubber Mobile by Aerus with a soft cloth dampened (not wet) with water . Do not use harsh chemicals or
solvents .
Fan/Interior of unit - The interior and fan may be cleared of dust using canned air suitable for electronics .
NOTE: See pages 5 - 6 for detailed views of components
TROUBLESHOOTING
CAUTION: Under no circumstances should your Air Scrubber Mobile by Aerus unit be operated while any part of the case is damaged,
missing, or disassembled . If the case is damaged, return your unit to Your Independent HVAC Contractor for repair or replacement .
Direct exposure to the internal UV light may cause eye damage .
Unit does not operate/the O
• Unplug and reinsert the adapter plug and adapter to check where the power supply is plugged in to be sure it has power .
• If using the 12VDC car adapter, remove the fuse by unscrewing the end of the adapter and check to see if it is blown . Replace it with the same type and
rating fuse only (see Specifications) . If the fuse is not blown, check the outlet for proper voltage .
UV bulb or O
Boost may not be working
3
• Press the PURIFIER UP or PURIFIER DOWN buttons to turn the Purifier function ON .
• If checking O
Boost operation, press the O
3
• Remove the Bulb Assembly, clean, and reinstall (see Disassembly and Cleaning) .
• If cleaning and reinstalling does not correct the problem, replace the Bulb Assembly (service kit #9950209) .
• When looking through the rear inlet vents in low light you should see a slight bluish glow . If there is no glow, replace the Bulb Assembly (service kit
#9950209) .
Lack of air flow
• Make sure the intake vents are not blocked and the front of the unit is clear .
• Check to see if the fan is operating (if not, see above) .
If your unit fails to operate properly after performing troubleshooting, contact your Independent HVAC Contractor for further assistance .
You may also contact Customer Service at 866 .736 .0503, or visit www .AirScrubberbyAerus .com for additional support .
6
Boost does not operate/all LEDs off
3
Boost UP button to turn the O
3
Boost ON .