DAB GENIX VT Instruction For Installation And Maintenance

DAB GENIX VT Instruction For Installation And Maintenance

Hide thumbs Also See for GENIX VT:

Advertisement

GENIX VT
INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GENIX VT and is the answer not in the manual?

Questions and answers

Summary of Contents for DAB GENIX VT

  • Page 1 GENIX VT INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE...
  • Page 2: Table Of Contents

    ENGLISH INDEX The following symbols have been used in the discussion: Key ......................2 SITUATION OF GENERAL DANGER. Warnings ....................2 Failure to respect the instructions that follow may cause harm to Responsibility ...................3 persons and property. General description ..................3 WARNINGS 1.
  • Page 3: Responsibility

    Make sure that all external pipework is adequately insulated.The discharge pipe must be made of rigid material, such as copper, Genix VT systems are compact small automatic lifting stations, suitable for or of rigid PVC with solvent-welded joints.To prevent the trans-...
  • Page 4: Electrical Connection

    ENGLISH Make sure to affix the “WaterMark” and “Prohibited items” stickers in a clearly visible location on the device. Certificate number: WM-022990 Technical specification: WMTS-106 6. MAINTENANCE Installation in accordance with Plumbing Code of Australia The system does not require any particular maintenance, but we recom- and AS/NZS3500.
  • Page 5: Technical Data

    (m3/h) Pressure switch pipe clogged 1. Disconnect the power supply 0.95 Genix VT 220-240 2. Unscrew the screw of the motor cover and remove the cover 0.91 3. If the water level is above the motor flange, empty the tank by means of the appropriate tap and the hose (supplied).
  • Page 6: Transport

    ENGLISH 8.2 Transport Avoid subjecting the products to needless impacts and collisions. 8.3 Weight The adhesive plate on the packaging indicates the total weight of the pump MODIFICATIONS AND SPARE PARTS Any modification made without prior authorisation relieves the manufacturer of all responsibility. All the spare parts used in re- pairs must be authentic and all accessories must be authorised by the manufacturer, in order to ensure maximum safety of the machines and of the systems in which they may be installed.
  • Page 7: Troubleshooting

    ENGLISH 11. TROUBLESHOOTING CHECKS FAULTS REMEDIES (possible causes) A. Reestablish the power supply. A. Supply failure. The motor does not start B. Replace the fuse.Measure cable and motor. If cable or B. Check the protection fuses. (if also the new fuse burns and does not produce noise motor is defective, replace the defective parts.
  • Page 8 ENGLISH...
  • Page 9 ENGLISH >2500 rpm...
  • Page 10 ENGLISH...
  • Page 11 ENGLISH 2° 2° Clack...
  • Page 12 308, 127247, Moscow - Russia Fax +49 2151 82136-36 info.russia@dwtgroup.com Tel. +7 495 122 0035 DAB PUMPS DE MÉXICO, S.A. DE C.V. DAB PUMPS (QINGDAO) CO. LTD. Fax +7 495 122 0036 Av Amsterdam 101 Local 4 No.40 Kaituo Road, Qingdao Economic &...

Table of Contents