  • Page 1 Itho Daalderop RFT RH sensor BAT Installation & Use...
  • Page 2 Translation of the original document.
  • Page 3 Introduction The installer is responsible for installing and Note commissioning the unit. Instructions important for the installation, The following definitions are used in this manual to draw functioning, operation or maintenance of the product. attention to hazards, instructions or indications related to Failure to observe these instructions can result in people, products, installations and/or the surroundings.
  • Page 4 Due to our continuous product improvement process, this document may not match the appliance you received. You can download the latest version of the manual from .
  • Page 5: Table Of Contents

    Contents Safety and other regulations Service & Maintenance Product information Warranty 2.1. Product description 2.2. Technical specifications Recycling 2.3. Application Declarations Installation Operation 4.1. Status 5.1. Pairing 5.2. Configuration settings 5.3. User settings...
  • Page 6: Safety And Other Regulations

    1. Safety and other regulations Do not use the product for This product and/or system ● ● purposes other than those for may be operated safely by which it is intended, as children aged 8 years and described in this manual. older and by people with physical, sensory or mental Take the following steps...
  • Page 7 Cleaning and maintenance by When removing the battery, ● ● the user may not be done by take care not to create a short children or people with circuit between the two battery physical, sensory or mental terminals or damage the disabilities or a lack of battery.
  • Page 8 The product may not be ● modified. Inspect the product regularly ● for faults. In the event of faults, immediately contact your installer or de fabrikant. Switch the product off if: ● The product is not working properly. You want to clean the outside of the product.
  • Page 9: Product Information

    2. Product information 2.1. Product description demand and communicates this wirelessly to the ventilation unit with which it is paired. ä Caution! Note Control based on wireless sensors (CO , RV and/or When the humidity level has fallen sufficiently, the PIR) only works when the ventilation unit is in Auto or capacity of the ventilation unit is automatically Auto-Night mode.
  • Page 10: Technical Specifications

    2.2. Technical specifications RV-sensor BAT Dimensions 99 x 100 x 29mm (L x W x H) Weight 0.1kg Installation 2 x 4mm screws (supplied) Housing ABS plastic (RAL 9003) Power supply Batteries (2 x 1.5V AA) Battery life 2 years (in normal use) Sensor type Capacitive, temperature adjusted Measurement range...
  • Page 11: Installation

    3. Installation ä Note Caution! With average use, the sensor batteries should last In a bathroom you should mount the sensor vertically approximately two years. When the batteries are and ideally near the shower at a height of almost empty, the sensor's status LED flashes red. approximately 2 metres above the floor.
  • Page 12 Open the sensor by manually releasing the latch at Attach the sensor to the wall with the supplied the bottom. screws and anchor plugs through the provided holes in the back of the sensor.
  • Page 13 Insert the supplied batteries (2x) into the battery compartment on the circuit board inside the cover. Place the cover with the circuit board back on the Pay attention the positions of the (+) and (–) installed wall support. terminals.
  • Page 14: Operation

    4. Operation 4.1. Status Touch button Ventilation speeds Status LED Timer Ventilation speed Auto/ Auto Night RFT-RV The status LED on the control switch shows the status of the ventilation unit: green : The ventilation unit and sensor Status LED lit ●...
  • Page 15 4.1.1. Ventilation speeds You can set the unit to different ventilation speeds (flow Ventilation speed sequence LED state rates) with this sensor. The current ventilation speed is (1) (2) Auto mode automatic mode green LED. indicated by a continuously lit Blinking Auto night mode automatic mode...
  • Page 16 2) Control based on wireless sensors (CO , RV and/or PIR) only works when the ventilation unit is in Auto or Auto-Night mode. 3) Auto night is available in combination with the RH sensor as well as the CO sensor. This speed is not available if more than one sensor is connected to the ventilation unit.
  • Page 17 4.1.2. Auto Night speed Such as the CO sensor, the RH sensor and the Spider air conditioning thermostat. Auto Night speed setting raises the minimum ventilation speed to ensure sufficient ventilation during The (dirty) filter indication is displayed by the status LED the night.
  • Page 18: Use

    5. Use 5.1. Pairing The pairing status is shown as follows: green (once per second): Status LED flashes Proceed as follows to link the sensor to the ventilation pairing successful; RF signal level good. The unit: ventilation unit briefly changes speed to indicate Set the ventilation unit to pairing mode as described that pairing was successful.
  • Page 19: Configuration Settings

    5.2. Configuration settings Confirm your choice by pressing and holding the touch button for 5 seconds until the status LED flashes blue. 9 to 11 seconds: Configuration setting 2: Setting the ● Note duration of maximum speed of the ventilation unit. The settings mode for the configuration settings as Hold the touch button down until the status LED well as for the user settings become available only...
  • Page 20 Option 3: 24 hours. Option 4: 48 hours. Confirm your choice by pressing and holding the touch button for 5 seconds until the status LED flashes blue. Configuration Setting Status LED Type of room (Bathroom/Laundry) On (blue) Flashes Maximum duration high speed * On (blue) Flashes Maximum duration not automatic**...
  • Page 21 The selected setting can be modified according to the Always press the touch button to go to the next option. schemes below. Confirm your choice by pressing and holding the touch button for 5 seconds until the status LED flashes blue. Type of room Status LED Bathroom *...
  • Page 22: User Settings

    5.3. User settings If the status LED is blinking orange: 5 to 7 seconds: Sending a reset message for the dirty ● filter indication. A reset message is sent to the Note ventilation unit. The settings mode for the configuration settings as well as for the user settings become available only Note after the sensor has been paired with the ventilation...
  • Page 23 Confirm your choice by pressing and holding the touch button for 5 seconds until the status LED flashes blue. Relative humidity Status LED 3% in 24 seconds (default). On (blue) 3% in 48 seconds On (blue)
  • Page 24 6. Service & Maintenance The RV-sensor requires little maintenance in principle. It The RV-sensor uses two penlight AA (1.5V) batteries. The is advisable to visually check the sensor once a year for battery life is approximately 2 years (in normal use). For correct mounting and contamination.
  • Page 25 7. Warranty...
  • Page 26 8. Recycling This product was manufactured using sustainable Any adverse effects on the environment and human materials. It should be disposed of in a responsible health are minimised by handling batteries and manner at the end of its life cycle. Your local authorities household appliances separately.