Safety for men and machines DNDS Kompakt Original Instruction manual Only for replacement requirements...
Page 2
The protection target of the low voltage directive will be fulfilled according to attachment I. 1. 5. 1 of the machinery directive. Producer: DINA Elektronik GmbH Address: Esslinger Str. 84, D-72649 Wolfschlugen The producer declares, that the product DNDS Kompakt with the module types as follows DNDS 1C DNDS 1D With optional external encoder adapter DNIA DNDS 2C DNDS 2D...
Page 3
Instruction manual DNDS Kompakt DNDS Kompakt DlNA Elektronik GmbH Esslinger Straße 84 72649 Wolfschlugen Tel. 07022/9517-0 Fax 07022/95 17-51 DNDS 1FA www.dinaelektronik.de info@dinaelektronik.de DNDS 1GA Quality management system DQS Certificate DIN EN ISO 9001: 2008 Reg.-Nr.67542 QM 08 DNDS 2FA...
Instruction manual DNDS Kompakt Safety regulations • The unit may only be installed and operated by those who are qualified electrical engineers or have received sufficient train- ing and are familiar with both these instructions and the current regulations for safety at work and accident prevention.
Instruction manual DNDS Kompakt DNDS 1D, 1GA, DNDS 2D, 2GA: Applications of the outputs STOP contacts: Standstill monitoring If the protection cover is closed and one or more drives are in movement, the NO-contacts 13-14 and 23-24 open immediately. The LED STOP is not illuminated. The protection cover cannot be opened.
Instruction manual DNDS Kompakt Function description: DNDS 1C, 1D, 1FA & 1GA DNDS 1C, 1D, 1FA & 1GA: The DNDS acts as a failsafe monitor of a rotary respectively linear motion and standstill. The speed monitor shut- down trigger point can be programmed via 4 inputs (D1–D4). This shutdown trigger point can be further modified from 100% down to 5 % via the 4inputs (F1–F4)
14,0 16,0 17,5 20,0 Mode 2 internel: internal ajusment only by DINA Elektronik. Mode 2 ist only active if F = NC Machine speed setting with DNDS 1FA, 1GA connected to24 VDC NC = open Automatic mode speed setting (mode 1)
Instruction manual DNDS Kompakt Reaction times The total reaction time is the sum of: Reaction time of the motion monitor • De-energisation time of the output relay (<20ms). • Delay of de-energisation on any external switching devices. • The reaction time of the motion monitor decreases as the speed to be monitored increases (linear).
After the D-inputs are switched off it can be switched over between tool setting speed (SH connected to 24V) and standstill (SH open). Machine speed setting with DNDS 2C, 2D Selection of function mode via D-inputs Internal only by DINA Elektronik 24 V D1/D4...
Instruction manual DNDS Kompakt Reaction times The total reaction time is the sum of: Reaction time of the motion monitor • De-energisation time of the output relay (<20ms). • Delay of de-energisation on any external switching devices. • The reaction time of the motion monitor decreases as the speed to be monitored increases (linear).
Instruction manual DNDS Kompakt Dimensions in mm DNDS 1C DNDS 1FA DNDS 1D DNDS 1GA DNDS 2C DNDS 2D DNDS 2GA Technical data Electrical data Operating voltage U 24 V DC Voltage tolerance U 90 - 110% Residual ripple U (DC) max.
Instruction manual DNDS Kompakt DNIA adaptor to the encoder: product description The DNIA Adapter is enclosed in a 45 mm housing. Features: 2 semi-conductor outputs. • Input to connect a encoder (15 pin D-sub-socket connector). • Output to machine control (15 pin D-sub-socket connector).
Page 16
Instruction manual DNDS Kompakt Setting of division factor ( ) for the encoder adaptation on the monitoring card S3 & S3 Position 1, 2, 5 & 7 = on ( ) = 2(1+1+2+16+64) = 2 x 84 = 168 S2 & S3 must have the same ajustment.