Page 2
A – Front view A1 – CO2 low alert icon A2 – CO2 high alert icon A3 – CO2 moving chart indicator A4 – CO2 readout A5 – CO2 sound alarm icon A6 – CO2 warning icon A7 – MIN icon A8 –...
Page 3
Installation Plug in the enclosed 5V-1.2A AC/DC adaptor to an AC wall outlet and then the DC jack to the back left side of your WL 1030 (B1). The display will come on with the relevant temperature and relative humidity.
Page 4
(default) flash and the to adjust the high alert level of RH% in steps of +/-1%. Highest alert level is 95%. 5) Press “CO2/RH% / SET” button (C4) again to confirm and end setting. The WL 1030 returns to normal display mode.
Page 5
Press and hold the “+“ or the “-“ button to accelerate the setting process. Your WL 1030 will store your settings and exit the alert set mode when no button is pressed in approximate 10 seconds. 4 different alert set-ups: CO2 low alert (default setting 400 ppm eq.)
Page 6
1) Press the “MEM” button (C3) one at a time to view the maximum => minimum record of the CO2, temperature and humidity (MAX or MIN icon appears) and then the 15-minute => 8-hour time weighted average of the CO2 level (15 M or 8Hr appears at the lower LCD). Note: You need to power on your monitor for at least 15 minutes to display the relevant last 15-minute weighted average of CO2 level (and also power on 8 hours to display the last 8-hour weight average).
Page 7
press and hold the “CALIBRATE” button (C2) until “CAL” flashes on the display. 2) In around 20 minutes, the blinking will stop and the initial calibration is completed. Your CO2 monitor will return to normal display mode and will continue the calibration in the background. It takes 24 hours to let your monitor run and display the correct CO2 level.
Page 8
Requires immediate ventilation! Declaration of conformity Hereby, Technotrade declares that this product WL 1030 are in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU and ROHS 2011/65/EC. The original EU declaration of...
Page 9
Specifications : 400 – 5000 PPM Measurement range Resolution : 1 PPM Accuracy : +/-5% +50 PPM Warm up time : 1 minute Temperature range : 0°C to 50°C / 32°F to 122°F Temperature resolution : 0.1°C / 0.2°F Relative humidity range : 20% - 95% Relative humidity resolution : 1% Operating temperature...
Page 10
Do not dispose this item in a fire as it may explode. Do not open the inner back case or tamper with any components of this item. Use the product only for its intended purpose! Consideration of duty according to the law of electrical devices This symbol means that you must dispose of electrical devices separated from the General household waste when it reaches the end of its useful life.