After unpacking your fan, carefully inspect for any damage that may have occurred during transit. Inspect for loose, missing or damaged parts.
If there is physical damage to any parts of the fan, a freight claim must be filed with the carrier. Check to assure that all bolts, screws and set
screws are securely tightened and have not become loose during transit. Retighten as required.
Warning:
1.
Before installing or servicing, disconnect all power. Keep hands and body parts clear of all moving parts when installing or servicing.
2.
Read and follow all instructions, cautions, dangers and warnings. Failure to do so could result in personal injury, death or property damage.
3.
Make sure the electrical power source conforms to the requirement of the fan(s) as well as local codes.
4.
Electrical connections, installation and maintenance must be done by qualified electrical personnel in accordance with all applicable codes.
5.
Unit must be adequately grounded.
6.
To reduce the risk of fire or electrical shock, do not expose this fan to water.
7.
Do not touch electrically live components.
8.
Free rotation of the propeller is critical. It must not touch any part of the venturi, framework or drive components.
9.
Assure that all power cords do not come in contact with any sharp edges, hot surfaces or chemicals. Immediately replace any damaged cords.
10. Keep hands and body parts clear of all moving parts when installing or servicing.
Caution: OSHA requires OSHA compliant guards within 7ft of the floor or working level.
Prop
# Of
Model
Dia.
Wings
36SW550
36"
425SW550
42"
425SW750
42"
425SW750-2
42"
48SW750-N
48"
48SW750-2N
48"
485SW750
48"
485SW750-2
48"
54SW750
54"
Fan Installation Tips:
For framing dimensions, refer to rough-in opening height and width shown in the specifications on the previous page.
Position the fan for desired airflow. Air will discharge on the side of the fan facing the propeller.
Assure the fan is fastened securely in the opening to avoid excess "rattling" or vibration using proper fasteners. Fasteners not included.
Refer to motor nameplate for wiring diagram.
MH-0003
Rev. 082719
Please read and save these instructions. Read carefully before attempting to assemble, install, operate
or maintain the equipment described within this manual. Carefully follow all safety information.
Save this manual for future reference.
Model # __________________________________________ Purchase Date:____________________
Tools/Materials Needed:
•
•
General Safety Instructions
Specifications
A
B
AA
(In.)
(In.)
(In.)
4
44
45 1/4
39 1/2
5
50
51 1/2
46
5
50
51 1/2
46
5
50
51 1/2
46
3
56
57 7/8
51 1/2
3
56
57 7/8
51 1/2
5
56
57 7/8
51 1/2
5
56
57 7/8
51 1/2
3
62 5/8 64 3/4
58 1/8
Instruction Manual: Galvanized Slant Wall
Exhaust Fans - Belt Driven
Model Numbers Covered:
36SW550, 425SW550, 425SW750, 425SW750-2, 48SW750-N,
48SW750-2N, 485SW750, 485SW750-2, 54SW750
Drill/drill bits/phillips bit
Ratchet/Socket set
Inspection:
(See Dimension Key On Following Page)
Dimension (In.)
BB
C
D
E
(In.)
(In.)
(In.)
(In.)
40 1/8
27
16 3/4
4 1/2 45 3/4
47 1/2
29 1/4
17 1/2
3
47 1/2
29 1/4
17 1/2
3
47 1/2
29 1/4
17 1/2
3
53 1/4
29 1/4
15 5/8
3
53 1/4
29 1/4
15 5/8
3
53 1/4
29 1/4
15 5/8
3
53 1/4
29 1/4
15 5/8
3
60 1/8
34 5/8
19 1/2
4 1/8
www.hessaire.com
Contents:
•
Exhaust Fan(1)
•
Instruction manual(1)
Rough-in Opening
F
Height
Width
(In.)
42 7/8
40 7/8
48
49 1/4
47
48
49 1/4
47
48
49 1/4
47
58 1/8
55 1/2
52 7/8
58 1/8
55 1/2
52 7/8
58 1/8
55 1/2
52 7/8
58 1/8
55 1/2
52 7/8
66
62 1/2
59 1/2
Ship
Ship.
Wt
Dims.
185
48x32x51
275
54x34x54
285
54x34x54
285
54x34x54
289
60x34x62
289
60x34x62
292
60x34x62
292
60x34x62
336
69x36x72
Need help?
Do you have a question about the 36SW550 and is the answer not in the manual?