Download Print this page
Modulift CMOD 12 User Instructions

Modulift CMOD 12 User Instructions

Spreader frame

Advertisement

Quick Links

User Instructions
CMOD 12 Spreader Frame
The CMOD Spreader Frame is modular in span and every frame consists of 4 Corner Units,
with intermediate Struts that can be bolted into the assembly to achieve different spans.
CMOD 12 has an assembled span ranging from 2ft by 2ft to 13ft by 13ft in 1ft increments.
Assembled
Frame
α
P1
Strut
CMOD 12 Frame Specification
Rated at a maximum of 16 tonnes SWL.
Please see Table 2 for SWL at specific spans.
'Base to Sling' angle,
Corner Units are rated at 4 tonnes each
(16 tonnes combined capacity).
Bolt tightening torque: 66 Pound-Foot. Spanner size required: 19mm.
Recommended additional equipment: Torque Wrench, Podger Spanner and Ring Spanner.
WARNING!
Personnel using this system should be suitably trained, competent and have a clear
understanding of Safe Slinging procedures.
The use of Modulift equipment must be in accordance with the procedures laid down in 'ASME B30.20 - 2013' .
Never exceed stated SWL
The top sling length is critical to the safe use of the spreader
Modulift UK Ltd tel: 011 44 1202 621511 email: sales@modulift.com www.modulift.com
Fig. 1 – Typical CMOD Spreader Frame Assembly
= Base to sling angle (BSA)
α
Span
Corner Unit
, no less than 45 degrees.
α
– Adhere to SWL in Table 2 for particular sling angle used.
P2–P5
Table 1 – Component List
Part Ref.
Description
P1
Corner Unit
P2
5ft Strut
P3
3ft Strut
P4
2ft Strut
P5
1ft Strut
P6
8.5t Shackle
P7
6.5t Shackle
P8
M12 x 35, Grade 8.8, HT Bolts, Nuts & Washers
– Ensure you refer to the correct table.
P8
P7
Weight/item
50 lbs
(length 1ft each)
41 lbs
28 lbs
21 lbs
14 lbs
5.7 lbs
3.9 lbs
P6

Advertisement

loading
Need help?

Need help?

Do you have a question about the CMOD 12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Modulift CMOD 12

  • Page 1 Personnel using this system should be suitably trained, competent and have a clear ● ● understanding of Safe Slinging procedures. The use of Modulift equipment must be in accordance with the procedures laid down in ‘ASME B30.20 - 2013’ . ● ● Never exceed stated SWL –...
  • Page 2 B’ , however the frame is modular and some arrangements may span is not noted in the table, then please round up be ‘Category A’ due to this please contact Modulift prior to any be ‘Category A’ due to this please contact Modulift prior to any or down to the values that will give you the lowest ‘Category B’...