Wiring Examples

The following illustrate how to connect power to single and dual power supplies.
RUGGEDCOM RS416PF
Installation Manual, 04/2021, C79000-G8976-1355-04
Connect the positive wire from the power source to terminal 5 (+/L) on the
terminal block.
1
3
3
3
Screw-Type Terminal Block
1
Pluggable Terminal Block
2
Jumper
3
Terminal 4 (Chassis Ground)
4
Terminal 5 (+/L)
5
Terminal 7 (-/N)
6
Chassis Ground Terminal
7
Figure 2.7
Terminal Block Wiring
Connect the negative wire from the power source to terminal 7 (-/N) on the
terminal block.
If the external PoE power supply features a chassis ground connection, connect
the ground terminal on the power supply to terminal 4 on the terminal block.
DANGER
Electrocution hazard – risk of death, serious personal injury and/or damage
to the device
Make sure the supplied terminal block cover is always installed before the
device is powered.
Install the terminal block cover.