CENTRIFUGAL INLINE FAN
TT
EN
USER'S MANUAL
www.ventilation-system.com

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TT and is the answer not in the manual?

Questions and answers

Summary of Contents for Vents TT

  • Page 1 CENTRIFUGAL INLINE FAN USER’S MANUAL www.ventilation-system.com...
  • Page 2: Table Of Contents

    CONTENTS Delivery set ..........................................6 Brief description ........................................7 Operation guidelines ......................................7 Designation key ........................................8 Mounting ..........................................9 Control logic ..........................................10 Maintenance ...........................................12 Storage and transportation regulations ..............................12 Manufacturer’s warranty ....................................13 This user’s manual is a main operating document intended for technical, maintenance, and operating staff. The manual contains information about purpose, technical details, operating principle, design, and installation of the ТТ...
  • Page 3 All user’s manual requirements as well as the provisions of all the applicable local and national construction, electrical, and technical norms and standards must be observed when installing and operating the unit. Disconnect the unit from the power supply prior to any connection, servicing, maintenance, and repair operations.
  • Page 4 • Do not use the unit in a hazardous or explosive environment containing spirits, gasoline, insecticides, etc. • Do not close or block the intake or extract vents in order to ensure the efficient air flow. • Do not sit on the unit and do not put objects on it.
  • Page 5 WARNING! Similar to the use of any other household electrical appliances when operating this fan, the following basic rules must be followed: • Never touch the unit with wet or damp hands. • Never touch the unit when barefoot. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person...
  • Page 6 If the supply cord is damaged, it must be replaced by the manufacturer, its service agent, or similarly qualified persons in order to avoid a safety hazard. If the cord set is damaged, it must be replaced by a special cord set available from the manufacturer or its service agent.
  • Page 7: Delivery Set

    The units for 100, 125, 150, 160 air ducts are equipped with a two-speed motor, for 250 and 315 air ducts – with a single-speed motor. Ø D ТТ 100 190/221* ТТ 125 190/221* ТТ 125 S 250/279* ТТ 150 250/279* ТТ 160 250/279* 323/340* ТТ 250 408/424* ТТ 315 *TT XXX U/Un/U1/U1n/U2/U2n/P...
  • Page 8: Operation Guidelines

    OPERATION GUIDELINES The fan is rated for connection to single-phase AC 220-240 V/50 Hz or 220 V/60 Hz power mains. The unit is rated for continuous operation. The arrow on the fan casing must match the air direction in the system. Ingress protection rating against access to hazardous parts and water ingress is IPX4.
  • Page 9: Designation Key

    DESIGNATION KEY ТТ Modifications: timer power cord with a plug speed switch speed controller with an electronic thermostat and a temperature sensor integrated inside an air duct. Temperature-based operation logic speed controller with an electronic thermostat and an outdoor temperature sensor fixed on a 4 m cord.
  • Page 10: Mounting

    MOUNTING The fan is designed for horizontal or vertical installation on the floor, on the wall or on the ceiling (Fig. 1). The fan can be installed independently or as part of a set with parallel or in-series connection (Fig. 2). To be installed on the intake spigot side: •...
  • Page 11: Control Logic

    Caution! The thermal switch of the ТТ 100 and ТТ 125 models cannot be reset. In case of overheating, replace the fan. TT 100/125/150/160 (R)V fans are equipped with a speed switch (Fig. 20). ТТ XXX T fan starts running after the external switch supplies control signal to the LT input terminal (for example, during turning the light on).
  • Page 12 TT XXX U/U1/U2(n) fan is equipped with an electronic TSC control unit (speed controller with electronic thermostat) for automatic speed control (air flow control) depending on the air temperature (Fig. 21). The terminal box cover incorporates 2 control knobs: •...
  • Page 13: Maintenance

    MAINTENANCE Clean the fan surfaces of dirt and dust each 6 months (Fig. 23–29). Disconnect the fan from power supply prior to any maintenance operations. For cleaning the fan use a soft cloth or a brush wetted in a mild detergent solution. Avoid water dripping on the electric components (Fig.
  • Page 14: Storage And Transportation Regulations

    STORAGE AND TRANSPORTATION REGULATIONS • Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range from +5 °C to +40 °C and relative humidity up to 70 %. • Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing deformation.
  • Page 15: Manufacturer's Warranty

    MANUFACTURER’S WARRANTY The product is in compliance with EU norms and standards on low voltage guidelines and electromagnetic compatibility. We hereby declare that the product complies with the provisions of Electromagnetic Compatibility (EMC) Directive 2014/30/EU of the European Parliament and of the Council, Low Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the Council and CE-marking Council Directive 93/68/EEC.
  • Page 16 • External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by the user. • Redesign or engineering changes to the unit. • Replacement and use of any assemblies, parts and components not approved by the manufacturer. •...
  • Page 17 min 1 m...
  • Page 20 ТТ 100/125/150/160 MAX / MIN ТТ 250/315...
  • Page 21 ТТ XXX T MAX / MIN MAX / MIN Terminal box for 5 contacts Terminal box for 4 contacts...
  • Page 23 2 min 30 min STOP...
  • Page 24 Temperature control knob ТТ U/U1/U2 ТТ Un/U1n/U2n Speed control knob m in m a x 2 0 °C 3 0 °C ТТ P Speed control knob m in m a x...
  • Page 27 Approval mark Sold (name and stamp of the seller) Manufacturing date Sales date...
  • Page 28 Certificate of acceptance ТТ_____________________ The fan is recognized as serviceable. V10EN-12...