5. OPERATION
5.1.
WARNING: Ensure that the cylinder is not pressurised before removing the
filler cap (fig.1.14).
5.1.1. To fill with blasting medium; unscrew the filler cap and pour the medium into
the cylinder via a funnel. Take care not to over-fill. Replace and tighten the
filler cap. DO NOT use any other medium than blasting soda in this
unit.
5.2.
Close the inlet valve (fig.1.8), delivery valve (fig.1.4) and delivery
regulator (fig.1.13). Screw down the regulator cap.
5.2.1. Connect to the compressed air supply, ensuring that the supply pressure
does not exceed 100psi.
5.2.2. Open the inlet valve and then increase the cylinder pressure by turning the
regulator cap in an anti-clockwise direction (the regulator can be locked by
pressing the cap down). The cylinder pressure is shown on the pressure
gauge (fig.1.7).
5.2.3. Open the delivery valve fully.
5.2.4. Open the delivery regulator slowly until the desired
blasting medium flow is achieved. DO NOT try to regulate the
flow by means of the delivery valve.
5.2.5. If the flow of blasting medium is not sufficient, increase the
cylinder pressure gradually by means of the main regulator until
a satisfactory flow is achieved.
5.2.6. Check the pressure gauge to ensure that the pressure parameters are not
exceeded.
5.2.7. Before filling the cylinder, turn the inlet valve off and vent the
pressure from the cylinder by opening the delivery valve
and delivery regulator. The pressure gauge displays the
current tank pressure.
6. MAINTENANCE
6.1.
The blasting medium must be used dry; any moisture is
likely to cause intermittent operation or blockage.
6.2.
When not in use, de-pressurise, close the inlet valve and
delivery valve and store in a warm, dry location. Keep away
from children.
6.3.
Clean with a moist soapy cloth. DO NOT use abrasive or solvent cleaners.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable dispose of it according to local regulations.
NOTE: It is our policy to improve products continually and as such we reserve the right to alter data, specifications and component parts without
prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack Sealey Limited
Environmental Protection
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
Key:
1: Valve Block
2: Cylinder Nut
3: Safety Valve
4: Delivery Valve
5: Regulator Bracket
6: Regulator Nut
7: Pressure Gauge
8: Inlet Valve
01284 757500
01284 703534
fig.1
9: Inlet Connector
10: Push Fit Connectors
11: Air Inlet Tube
12: Delivery Tube
13: Delivery Regulator
14: Filler Cap
15: Pressure Regulator
www.sealey.co.uk
sales@sealey.co.uk
PBS10, PBS40 Version: 1 - 25/02/16

Advertisement

loading

This manual is also suitable for:

Psb40