ALARM CENTRAL
Congratulations,
You have just acquired a product with JFL Alarmes quality, produced in Brazil with the highest
manufacturing technology. This manual shows all the functions of the equipment.
www.jfl.com.br

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMARTCLOUD 18 and is the answer not in the manual?

Questions and answers

Summary of Contents for JFL Alarmes SMARTCLOUD 18

  • Page 1 User Manual SMARTCLOUD 18 ALARM CENTRAL Congratulations, You have just acquired a product with JFL Alarmes quality, produced in Brazil with the highest manufacturing technology. This manual shows all the functions of the equipment. www.jfl.com.br...
  • Page 2: Table Of Contents

    Í NDICE 1 FRONT PANEL:..................................3 2 PROGRAMMING OF WIRELESS SENSORS AND REMOTE CONTROLS................3 3 PROGRAMMING OF THE BUS SENSORS..........................4 4 ARMING AND DISARMING OF THE CENTRAL UNIT......................5 5 ENABLE AND DISABLE THE DIVIDED MODE........................6 6 ENABLE AND DISABLE THE CONTINUOUS OR INTERRUPTED TRIGGERING..............6 7 PANIC BY REMOTE CONTROL...............................7 8 PROGRAMMING MODE.................................7 9 AUTOMATIC REARMING AFTER DISARMING........................7...
  • Page 3: Front Panel

    FRONT PANEL: Rede/Bateria LED: Indicates the power supply of the device. Green means connected to the AC network, while yellow means connected to the bateria. Zona 1 LED / Zona 2 LED: Indicates the current state of zones 1 and 2, with the following characteristics: •...
  • Page 4: Programming Of The Bus Sensors

    PROGRAMMING OF THE BUS SENSORS The JFL SmartCloud 18 central unit offers the bus technology, which allows increasing the sector capacity using only one pair of wires. It is possible to add 18 bus devices, with 16 being sensors and 2, sirens. The operation zones of the sensors may be sequential or random, allowing the recording of 16 sensors in one zone or one sensor per zone.
  • Page 5: Arming And Disarming Of The Central Unit

    5-To finalize the recording of the bus sensor, press and release the programar button (the central unit issues 2 beeps of the siren). 6-To program the bus siren, press and release the programar button. Next, approximate a magnet to the siren according to the image on the side. The bus siren issues a beep, and the central unit detects the serial number of the device and confirms with 2 beeps of the siren (SIR out).
  • Page 6: Enable And Disable The Divided Mode

    which device has a problem, connect the programmer software to the central unit and visualize on the monitor screen, or access through the application with the use of the ME-04 Ethernet module. To disarm the central unit, press and release a programmed button of the remote control;...
  • Page 7: Panic By Remote Control

    PANIC BY REMOTE CONTROL Press and hold button 3 of the remote control for 4 seconds. The PGM relay triggers for 6 seconds, then deactivates. Obs.: - Button 3 of the remote control must be programmed. - The PGM must be programmed to work along with the SIR out. PROGRAMMING MODE With the central unit disarmed, press and hold the programar button until the programar LED turns off.
  • Page 8: Automatic Arming For Lack Of Movement

    12 AUTOMATIC ARMING FOR LACK OF MOVEMENT This function allows the central unit to automatically arm due to lack of movement in the premises. To program, follow the instruction below: With the central unit in the programming mode, press and release button 3 of the remote control;...
  • Page 9: Installation

    3-For a partial reset, release the aprender button while the LED is flashing (from 0 to 5 seconds). 4-For a total reset, release the aprender button only when the LED stops flashing (time of 10 seconds). Obs.: The reset does not erase the memory of the remote controls, wireless sensors, and bus sensors. 15 INSTALLATION To install the central unit, choose a discrete location, out of the view of strange persons, and attach it to the wall.
  • Page 10: Device Parts

    DEVICE PARTS 1- 433.92 MHz receiver antenna. 2-APRENDER button for programming the wireless sensor and remote control. 3-PROGRAMAR button to program the central unit and aprender bus devices. 4-AC: Transformer input (12 VAC). 5-Battery: Input connector for a 12 V / 7 A battery. 6-+B: Positive battery out.
  • Page 11: Connection Scheme

    18 CONNECTION SCHEME Obs.: - For installations with greater wiring distances, it is recommended to pass a wire of larger gauge as the bus. -For the installation of the bus sensors, use wiring with AWG26 (0.2 mm) gauge for a distance of up to 100 m or a minimum gauge of 0.5 mm for up to 200 m between the central unit and the last sensor, provided the wire resistance does not surpass 20 U.
  • Page 12: Interconnection With The Ethernet Module

    1-Download the Cloud line programming software and the programming cable driver from our website www.jfl.com.br and install on the computer. Or look for the JFL Programmer APP on the store and install it on your smartphone. 1- Open the Cloud line programmer and follow the instructions of the HELP field to connect the central unit.
  • Page 13: Interconnection With The Jfl Energizer

    Siren sounds upon triggering of up to 30 seconds; • Groups the notifications from the same location. 22 INTERCONNECTION WITH THE JFL ENERGIZER 1- Connect the energizer to the JFL SmartCloud 18 central unit according to the figure above. www.jfl.com.br...
  • Page 14: Interconnection Of The Pgm Module (Optional Not Included )

    2-Connect the central to the Cloud line programmer software (item 19) and program the PGM field as “Energizer function”; automatically, the Z1 terminal will be configured as “Energizer trigger” and the Z2 as “Arming/disarming of the energizer”. Obs.: For the functioning of the “energizer function”, the programming of zones 1 and 2 cannot be disabled.
  • Page 15 PRECAUTIONS: Do not try to adjust or modify the device. • Maintenance may only be performed by persons indicated by JFL. • The device owner must test the sensors at least once a week to be sure that the batteries are good for the sensors to work properly when violated.
  • Page 16 WARRANTY JFL Equipamentos Eletrônicos Indústria e Comércio Ltda warrants this device for a period of 12 months from the date of purchase, against manufacturing defects that prevent its operation within the specified technical characteristics of the product. During the warranty period, JFL will repair (or replace, at its sole discretion), any defective components.