Features; Internal Parts And Wiring Diagram Lynx Distributor; Fuse Detection - Victron energy Lynx Distributor Manual

Hide thumbs Also See for Lynx Distributor:
Table of Contents

Advertisement

3. Features

3.1. Internal parts and wiring diagram Lynx Distributor

The internal physical parts and the wiring diagram of the Lynx Distributor indicating the following parts
• Positive busbar
• Negative busbar
• Fuses
• Positive connections
• Negative connections
• Ground connection
Positive Busbar
Negative Busbar
The Internal physical parts of the Lynx Distributor
+
F1
-
- +
The internal wiring diagram of the Lynx Distributor

3.2. Fuse detection

The Lynx Distributor monitors each fuse and will detect a blown fuse.
When a fuse blows, the red fuse LED will illuminate, the power LED will turn red and an alarm message is send to a connected
Lynx Smart BMS.
Fuse detection is possible from all fuses on the battery side or on the load or charger side. Be aware that the fuse detection has a
particularity; when batteries are connected to multiple Lynx Distributor circuits and if one of the battery fuses blows, the fuse
monitor will not measure a high enough voltage over the fuse to trigger a broken fuse alarm, until the battery is being charged or
discharged.
Page 4
Lynx Distributor
Ground connection
F2
F3
- +
GND
- +
+
F4
-
- +
Fuses
Positive
connections
Negative
connections