  • Page 1 USER MANUAL UG110, UG110V, UG110VP SPRAY GUN CLEANERS UG110 •• 381 Bentley Street, Markham ON L3R 9T2 • Tel. 1-800-417-9133 WWW.UNIRAM.COM • sales@uniram.com Revised 2020-06 CORPORATION...
  • Page 2: Table Of Contents

    MANUAL - UG110 SERIES GUN CLEANERS REVISED 2020-06 CONTENTS INTRODUCTION ............. . 4 SETUP INSPECTION and ASSEMBLY .
  • Page 3 MANUAL - UG110 SERIES GUN CLEANERS REVISED 2020-06 UG110 Wash Tank (inside) Timer Diaphragm Drain Valve (inside) Pump Suction Hose Drain Hose (rear) Comercial Pail of solvent provided by the User.
  • Page 4: Introduction

    REVISED 2020-06 INTRODUCTION Uni-ram holds many patents on designs used in its innovative products. Every machine is tested for compliance with Quality Assurance standards. Follow the directions in this manual under Setup, Operation and Maintenance in order to operate this machine safely and effectively. Not following these instruction can lead to malfunction or damage to the machine.
  • Page 5: Solvent Pail Setup

    MANUAL - UG110 SERIES GUN CLEANERS REVISED 2020-06 vent is critical. Only use good quality solvent that is formulated for your paint and intended for use with automatic spray guns cleaners. SOLVENT PAIL SETUP • Close the Drain Valve under the unit (handle in horizontal position) if it is not already closed.
  • Page 6: After Cleaning

    MANUAL - UG110 SERIES GUN CLEANERS REVISED 2020-06 and wipe them dry. Do not store spray guns in the tank UG110VP ONLY Place pot ovet rotating spray jet. DAILY MAINTENANCE SCREEN • Inspect the screen at the bottom of the tank and clean when necessary.
  • Page 7: Troubleshooting Chart

    MANUAL - UG110 SERIES GUN CLEANERS REVISED 2020-06 TROUBLESHOOTING CHART SYMPTOM REASON ACTION PUMP LEAKS AIR OR Pump is defective Replace pump LIQUID WASH LIQUID DOES NOT FLOW Water in air line causes • Follow Procedure 1, Blockage in Air...
  • Page 8: Troubleshooting Procedures

    MANUAL - UG110 SERIES GUN CLEANERS REVISED 2020-06 TROUBLESHOOTING PROCEDURES Note: Pumps shown are 4" Pumps; follow same procedures for 2" Pumps. PROCEDURE 1 Blocked Fluid Passage In Diaphagm Pump If the pump sounds like it is working but liquid does not flow, clear the fluid passage as follows: •...
  • Page 9: Flow Diagrams

    MANUAL - UG110 SERIES GUN CLEANERS REVISED 2020-06 FLOW DIAGRAMS - Use to trace the flow of compressed air and water.
  • Page 10: Replacement Parts

    MANUAL - UG110 SERIES GUN CLEANERS REVISED 2020-06 REPLACEMENT PARTS DESCRIPTION PART NUMBER Nozzle Adapter, Push On, Conventional Systems Only 110-430 Nozzle Adapter, Push On, Disposable and Conventional Systems 110-430PPS Paint Cap Holder 100-413F Mechanical Timer Assembly, 5 minutes 115-200/K...
  • Page 11: Warranty

    "Conditions of Warranty" as consumables are not covered. Uni-ram reserves the right to direct the customer to ship the unit collect to the Uni-ram factory or to an approved Service Center for repair using the Uni-ram Return Goods Procedure or to repair the unit on-site.