Winco TransMotion TMM3 Owners Operating & Maintenance Manual

Winco TransMotion TMM3 Owners Operating & Maintenance Manual

Stretcher-chairs

Advertisement

TMM3 STRETCHER-CHAIR
OWNERS OPERATING & MAINTENANCE MANUAL
IMPORTANT - DO NOT DISCARD THIS MANUAL.
KEEP THIS MANUAL FOR FUTURE REFERENCE AND
ONE PATIENT, ONE SURFACE®
TRAINING.
VIDEO FLUOROSCOPY
OPTIONS
S
SHORT BASE
F
FOLDING FOOTREST
E
EXPORT
B
BATTERY
A
AC POWER
Document #OM-TMM-2228-13 REV V

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TransMotion TMM3 and is the answer not in the manual?

Questions and answers

Summary of Contents for Winco TransMotion TMM3

  • Page 1 TMM3 STRETCHER-CHAIR VIDEO FLUOROSCOPY OWNERS OPERATING & MAINTENANCE MANUAL OPTIONS SHORT BASE FOLDING FOOTREST EXPORT BATTERY AC POWER IMPORTANT - DO NOT DISCARD THIS MANUAL. KEEP THIS MANUAL FOR FUTURE REFERENCE AND TRAINING. ONE PATIENT, ONE SURFACE® Document #OM-TMM-2228-13 REV V...
  • Page 2: Signal Words / Symbols

    IF YOU HAVE ANY QUESTIONS OR CONCERNS, PLEASE CONTACT WINCO MFG., LLC. Winco assumes no responsibility for damage or injury caused by improper assembly, installation, use, or maintenance of these products. No part of this manual may be duplicated in any form without the prior consent of Winco Mfg., LLC.
  • Page 3: Table Of Contents

    OWNERS OPERATING & MAINTENANCE MANUAL TABLE OF CONTENTS TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR ........................2 Signal Words / Symbols ........................4 Intended Use Statement ..............4 Transportation, Storage, Handling & Disposal ..................... 4 Preparation: Before you begin ......................5 Power / Cable Requirements ...........................
  • Page 4: Intended Use Statement

    • The product should be stored in an environment that will inhibit rust/mold formation. • Winco Mfg., LLC recommends not leaving the product in the factory packing in excess of three (3) months. • The product should always be handled in a manner consistent with the user instructions and in a manner to prevent contamination after each use.
  • Page 5: Power / Cable Requirements

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR POWER / CABLE REQUIREMENTS For options A, B & E, see the "Options" section of this manual for additional details regarding powering this product. Only use the power/charging cord that came with your TMM3 Video Fluoroscopy Stretcher-Chair. SAFETY PRECAUTIONS WARNINGS CHAIR OPERATION BY QUALIFIED, TRAINED MEDICAL PERSONNEL ONLY...
  • Page 6: Accessory Warnings

    Only equipment approved by TransMotion by Winco is to be mounted on surgical rails. TransMotion by Winco is not responsible for damage and assumes no liability caused by the use of unapproved equipment or accessories.
  • Page 7: Cautions

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR CAUTIONS DO NOT MODIFY CHAIR Modifying chair can cause unpredictable operation resulting in injury to patient, medical personnel, or bystander. Modifying chair will void warranty and may cause unsafe operating conditions. USE SAFE OPERATING PROCEDURES Prior to operating chair, ensure patient clearance by moving any overhanging equipment or moving chair from under a table to prevent patient injury.
  • Page 8: Emi Cautions

    50 pounds to device. Weight of patient plus weight of equipment should not exceed 500 pound weight capacity of TransMotion by Winco stretcher-chair. EMI CAUTIONS EMI MAY AFFECT CHAIR FUNCTIONALITY...
  • Page 9: Notices

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR NOTICES MAXIMUM PATIENT WEIGHT IS 350 POUNDS (158 KG) Maximum patient weight capacity of chair is 350 pounds. If exceeded, damage to chair could occur. CHAIR IS INTENDED FOR INDOOR USE ONLY To ensure proper operation and extend chair life, only use chair in specified environment.
  • Page 10: Product Labels / Diagrams

    Every three (3) months, inspect all labels and ensure they are legible and not tattered, torn or missing. Refer to the label locations in figure below. If labels need replacing, contact TransMotion by Winco Customer Service at 1-800-237-3377. Item No.
  • Page 11: Options

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR OPTIONS "A" A/C POWER OPTION "B" BATTERY POWER OPTION TMM-208-10 Power Light Label TMA57-15 Universal Charger Assembly TMM-222-10 Charge Battery Label TMM-523-10 Battery Removal Label "E" EXPORT PLUG OPTION "F" FOLDING FOOTREST OPTION TMM-1057-XX Power Cord - Universal Charger TMM-202-10...
  • Page 12: Operating Instructions

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR OPERATING INSTRUCTIONS QUICK RELEASE BACK SECTION 1. LOCATE MANUAL QUICK RELEASE LEVER Back section quick release (red) lever is located under seat on patient’s right side. 2. ACTIVATE RELEASE LEVER To activate quick release of back section, pull the red lever out. When weight is applied, the back section will drop until the lever is released.
  • Page 13: Caster Brake Operation

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR CASTER BRAKE OPERATION • BRAKE MODE: To activate, press down on red end of either brake pedal located at base of chair. Note: Brake mode prevents all four casters from swiveling and all wheels from spinning.
  • Page 14: Adjusting Side Rail Angle

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR OPERATING INSTRUCTIONS: CONTINUED • STOWING SIDE RAIL Once the rail is lowered (“down” position), push the rail to fully engage the side rail retainer clip. • RAISING SIDE RAIL Lift side rail until it is in “up” position. NOTE: Red rail release tab will engage (lock) automatically.
  • Page 15: Pendant (Controller)

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR PENDANT (CONTROLLER) PENDANT IS NOT INTENDED FOR PATIENT’S USE To prevent damage, pendant can be stored at various locations on the chair when not in use. ENSURE AREA IS CLEAR OF OBSTRUCTIONS PRIOR TO PENDANT USE To prevent property damage or injury to patient, survey area for possible obstructions prior to pendant use.
  • Page 16: Patient Ingress / Egress

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR OPERATING INSTRUCTIONS: CONTINUED PATIENT INGRESS / EGRESS PATIENT SHOULD NEVER BE PERMITTED TO ENTER OR EXIT FROM ENDS OF STRETCHER-CHAIR WHEN IN AN UPRIGHT, PARTIALLY, OR TOTALLY RECLINED POSITION. EXCESSIVE WEIGHT ON ENDS COULD CAUSE CHAIR TO TILT, RESULTING IN POSSIBLE PATIENT INJURY.
  • Page 17: Patient Transfer

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR PATIENT TRANSFER PATIENT’S BODY WEIGHT SHOULD NEVER BE SHIFTED TOWARDS EITHER END OF CHAIR WHEN IN A PARTIALLY, OR TOTALLY, RECLINED POSITION. SERIOUS PATIENT INJURY MAY OCCUR. ALL PATIENT TRANSFERS MUST BE MADE TO RIGHT SIDE OF TMM3-SERIES CHAIR, DUE TO SHAPE OF BACK SECTION, AND NOT TO CHAIR ENDS.
  • Page 18: Seat Rotation

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR OPERATING INSTRUCTIONS: CONTINUED SEAT ROTATION ONCE SEAT IS ROTATED, DO NOT RECLINE BACK SECTION OR POSITION CHAIR IN HORIZONTAL ORIENTATION TO AVOID TIPPING AND PATIENT INJURY. WITH SEAT IN ROTATED POSITION, DO NOT TRANSPORT PATIENT OR ATTEMPT PATIENT TRANSFER TO AND/OR FROM ANOTHER SURFACE.
  • Page 19: Options

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR OPTIONS “S” OPTION: SHORT BASE For “S” option, wheel base length is 26”. Standard wheel base length is 30”. “F” OPTION: MANUAL FOLDING FOOTREST WHEN POSITIONING FOOTREST, BE AWARE OF PINCH POINTS NOTE: For patient comfort, stow footrest prior to articulating chair into supine (stretcher) position.
  • Page 20: B" Option: Battery Pack

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR OPTIONS: CONTINUED “B” OPTION: BATTERY PACK • REMOVING BATTERY PACK FROM CHAIR Grasp integrated handle on battery pack and pull away from chair until cam locks disengage. Remove battery from mounting bracket. •...
  • Page 21: A" Option: Ac Power (For On-Board Batteries And Charger)

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR “A” OPTION: AC POWER (FOR ON-BOARD BATTERIES AND CHARGER) The AC power cord for charging on-board batteries is attached to the chair base and may be stowed by wrapping around storage bracket. TO CHARGE ON-BOARD BATTERIES: •...
  • Page 22: Switch Schematic

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR SWITCH SCHEMATIC • "A" Option Only: Ground wire attaches to GROUND POST • Battery cord plugs into PORT #13 • Plug column cord plug into phono din adapter, then plug into PORT #1 •...
  • Page 23: Pad Set Care

    Contact the manufacturer of the fabric or vinyl used on your pads, pad sets and/or pillows for a current list of approved disinfectants. Refer to the Vinyl and Cushion Information page on Winco's website for current links to manufacturer materials.
  • Page 24: Preventative Maintenance

    OWNERS OPERATING & MAINTENANCE MANUAL TMM3 VIDEO FLUOROSCOPY STRETCHER-CHAIR PREVENTATIVE MAINTENANCE To ensure proper operation and to extend the life of your stretcher-chair, it should be maintained on a regular basis per recommendations below. PADS / PAD SETS / PILLOWS: After each use, inspect for tears.
  • Page 25 BATTERY LIFE NOTE: Battery capacity diminishes over time. Charge batteries regularly to maintain healthy battery life. TransMotion by Winco recommends replacing your battery every two years or sooner if required. Use of Batteries that are NOT factory approved will void any and all warranties.
  • Page 26: Warranty Information

    The Limited Warranty period begins when the product is delivered to the Buyer. The Limited Warranty applies when the product is used and cared for as specified by Winco Mfg., LLC. If the product is not used and cared for as specified, the Limited Warranty is void. Adjustments under this Limited Warranty will be made only after completion of inspection of the part or product by Winco Mfg.,...
  • Page 27: Service And Contact Information

    SERVICE AND CONTACT INFORMATION Customer service and support are important aspects of each TransMotion by Winco product. Prior to contacting TransMotion by Winco for assistance with your chair, please HAVE YOUR CHAIR’S SERIAL NUMBER AVAILABLE (refer to label diagram for location).
  • Page 28 Effective 10.21.2020 - Revision V: Re branded updated layout, added warranty information CONTACT US To arrange a demonstration or to speak with one of our associates, please feel free to contact us at: 800-237-3377 | WincoMfg.com | 5516 SW 1st Lane, Ocala, FL 34474 | Info@WincoMfg.com Copyright 2020 Winco Mfg., LLC...

Table of Contents

Save PDF