Sealey LED044S Instructions page 2

Floodlight with wall bracket & pir sensor 9 smd led 230v

Advertisement

4.
ASSEMBLY
WARNING! DO NOT connect unit to the mains power supply before installation.
4.1.
Installation
4.1.1. Give careful consideration to the position of unit to ensure you obtain maximum benefit from the lighting range, and that an appropriate
electrical power source can be provided.
4.1.2. An approximate appropriate mounting height from the ground is 2.5m.
4.1.3. this sMD LED floodlight develops minimal heat and is not subject to the same mounting restrictions that apply to halogen lamps that
become too hot to touch. We do however recommend that the floodlight should not be placed in cramped or restrictive positions and
should be fixed at the following minimum distances between the light and any surface/object. see fig.3.
● 500mm minimum between the top of the light and any overhead surface, or objects, i.e. ceilings, overhangs.
● 200mm between sides of light and end or side walls, surface or objects.
● 2 metres minimum between the front of the light and any object to be illuminated.
4.1.4. fix the light to a vertical surface with appropriate fixings.
4.1.5. DO NOT tilt the light back beyond 30° (fig 3B) or forward more than 45° (fig 3c). When set and ready, the lamp can be connected to the
mains by a qualified electrician.
4.2.
Sensor
the sensor may be angled independently of the light. Mounted at
approximately 2.5m above the ground the sensor will have approx
12m range (fig 4) with a 120º spread (fig.5)
4.2.1. the sensor range can be reduced or optically adapted to local
conditions by adjusting the sensor angle accordingly.
4.2.2. further adjustment may be made by tuning the three switches located
on the underside of the sensor as follows: (refer to fig.5).
Switch 1. Sensitivity. the sensor range will vary with temperature
and factors such as passing cars, shade from large trees etc.
During cold weather the sensor range will be greater than when hot
in summer temperatures. for example during hot weather the
forward detection range could fall from 12 to 6m and as such the
sensor should be checked and adjusted. note: the sensitivity factor is far greater when an object passes across the detection area
(fig.4A) than when an object approaches towards the detector (B).
Switch 2. Time adjuster: to adjust the amount of time the light will stay on when activated. Minimum is 6 seconds, maximum is 20
minutes.
Switch 3. Daylight adjustment: to adjust the sensor to come on in accordance with the diminishing daylight. from 0 to 30 Lux.
5.
MAINTENANCE
5.1.
clean the casing externally (not the glass) with a moist cloth.
5.2.
DO NOT use solvents or abrasives to clean the light.
5.3.
Avoid touching the glass shield as handling may reduce its serviceable life and cause the glass to crack. if necessary clean the glass
shield with alcohol and a soft cloth. undo the single screw without removing it to clean internally (fig.2).
5.4.
DO NOT use the light without the glass shield.
5.5.
DO NOT use the light without the weather seals intact.
Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to
www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
Dispose of this product at the end of its working life in compliance with the EU Directive on
Waste Electrical and Electronic Equipment (WEEE). When the product is no longer required, it must be disposed
of in an environmentally protective way. Contact your local solid waste authority for recycling information.
noTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: no liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
© Jack sealey Limited
fig.3
Sole UK Distributor, Sealey Group,
Kempson Way, suffolk Business Park,
Bury st. Edmunds, suffolk,
iP32 7Ar
Original Language Version
Elevation
fig.5
Environmental Protection
WEEE Regulations
01284 757500
01284 703534
fig.4
www.sealey.co.uk
Web
sales@sealey.co.uk
email
LED044s
issue: 1 - 02/04/14