Advertisement

Fast & Fluid Management B.V. – SK450 / SK550
FAST & FLUID MANAGEMENT
SK450 / SK550
ENGLISH
V. 04‐2013 
 
P1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SK450 and is the answer not in the manual?

Questions and answers

Summary of Contents for Fast & Fluid Management SK450

  • Page 1 Fast & Fluid Management B.V. – SK450 / SK550 FAST & FLUID MANAGEMENT SK450 / SK550 ENGLISH V. 04‐2013   ...
  • Page 2: Table Of Contents

    Fast & Fluid Management B.V. – SK450 / SK550 Table of Contents SK450 / SK550 Manual Introduction, warranty & CE certification Main SK450 / SK550 components Safety instructions Installation 6 – 8 Operation 9 – 12 Maintenance Problem solving 14 – 15...
  • Page 3 Fast & Fluid Management B.V. – SK450 / SK550 Introduction & warranty Introduction By selecting a Fast & Fluid Management shaker you have opted for a product which is the result of intensive research. Top-quality components, craftsmanship and a modern ergonomic design all serve to guarantee a long service life and a high degree of user friendliness.
  • Page 4: Main Sk450 / Sk550 Components

    Fast & & Fluid Mana agement B.V V. – SK450 / S SK550 Main S SK450 0 / SK5 550 co mpone ents 1. Top lid 2. Interfac ce & Emerg gency stop button 3. Transfo rmer 4. Power B Board 5.
  • Page 5: Safety Instructions

    Specific safety instructions in this manual Attention! Failure to remove the frame lock correctly can result in severe damage to your SK450 / SK550 when in operation. Please take care! Attention! To prevent damage, the SK450 / SK550 may only be connected to either 220-240V/16A/50Hz power grids.
  • Page 6: Installation

    Be careful not to damage the body and surfaces of your SK450 / SK550 with any tools while unpacking it. Take care not to accidentally close the door before finishing installation, as it can then only be unlocked power on the machine.
  • Page 7 Tip: before locking the adjustable feet, start a mixing cycle with a small load (<5kg). While the SK450 / SK550 runs, check if all four feet are firmly in contact with the floor and then lock them. V. 04‐2013 ...
  • Page 8 Connect the power cable Ensure the emergency stop is to the socket at the rear unlocked (turn clockwise). of the machine. Attention! To prevent damage, the SK450 / SK550 may only be connected to either 220-240V/16A/50Hz power grids. V. 04‐2013   ...
  • Page 9: Operation

    Fast & & Fluid Mana agement B.V V. – SK450 / S SK550 Opera ation A - Firs t time o operation Attention n! Before operating g your SK K450 / SK K550 for t the first t time, please en...
  • Page 10 Fast & & Fluid Mana agement B.V V. – SK450 / S SK550 Step 2 2 - Corre ect place ement o f cans a and othe er contai iners > > Place one e or more Place fil ler disc on...
  • Page 11 Fast & & Fluid Mana agement B.V V. – SK450 / S SK550 B - Ope erating t the SK45 50 / SK5 Step 1 1 - Place e can, ch hoose th he shakin ng time and pus sh the s tart key >...
  • Page 12 Fast & & Fluid Mana agement B.V V. – SK450 / S SK550 C - Use er preset ts for th e SK450 0 / SK55 Certain SK K450 / SK5 50 softwar e presets c can be adju sted using...
  • Page 13: Maintenance

    Fast & Fluid Management B.V. – SK450 / SK550 Maintenance Keep your SK450 / SK550 clean and free of paint residue > Remove all spilt paint Though the SK450 / SK550 is from accessible parts designed to be completely (especially clamping plate maintenance free, periodic spindles).
  • Page 14: Problem Solving

    Fast & Fluid Management B.V. – SK450 / SK550 Problem solving Introduction Before calling your machine supplier or Service Department, please check whether you can solve the problem yourself. If you cannot, then call the Service Department for advice. Have the model number and serial number at hand (these can be found on the silver sticker at the back of the machine).
  • Page 15 Fast & Fluid Management B.V. – SK450 / SK550 Clamping plate will not go Clamping plate jammed Use interface user setting U4 down Fuse blown Shut power off and replace fuse Machine starts shaking Too much spindle resistance Clean the spindles and lubricate...
  • Page 16: Service And Support, Fuses

    Fast & Fluid Management B.V. – SK450 / SK550 Error codes Error Cause Action Clamping motor power too low or bad Call service electric wiring Preset minimal clamping pressure not Call service reached Door opened during mixing or door Keep door closed during mixing. If...
  • Page 17 Fast & Fluid Management B.V. – SK450 / SK550 Fuses Replace fuse at rear of SK450 / SK550. > Remove mains connector The inner fuse is the Dispose of the burnt fuse and and pull fuse tray (damaged) one to replace, the in time, remember to get a new outwards.
  • Page 18: Specifications

    Fast & Fluid Management B.V. – SK450 / SK550 Specifications Maximum product weight 40 kg Timer electronic/programmable Maximum product size (H x W x D) 45 x 35 x 35 cm Minimum product height 7 cm Clamping automatic Clamping pressure...
  • Page 19: Electrical Wiring Diagram

    Fast & Fluid Management B.V. – SK450 / SK550 Electrical wiring diagram V. 04‐2013   ...
  • Page 20: Contributing To The Protection Of The Environment

    Fast & Fluid Management B.V. – SK450 / SK550 Contributing to the Protection of the Environment Packaging Material The packaging protects the machine against damage during transport. The packaging material was chosen based on its limited impact on the environment and its inherent possibilities for waste-disposal.
  • Page 21 Fast & Fluid Management B.V. – SK450 / SK550 © Fast & Fluid, 2013 www.Fast-Fluid.com V. 04‐2013   ...

This manual is also suitable for: