When replacing VC board (in case adjustment values cannot be read):
1.
Read the QR code printed in EVF display device (LCD902) using with "QR_Code_Reader_Ver1.0_x64".
2.
Make sure the adjustment value from the read value as shown below, and memorize it.
Example when QR code is 1958817021A
1
2
3
4
5
1
9
5
8
8
195
Brightness value
3.
Start the Adjust Manual in the Adjust Station and execute the "EVF Data Input" on the ADJUST tab.

1-7-4. Checking the Wi-Fi Function

After this unit has been disassembled and reassembled, check the Wi-Fi function.
Required equipment:
Personal computer or smartphone with Wi-Fi interface
Procedure:
1.
Turn on the unit and enable the Wi-Fi function.
Tip
Upon completion of the preparation for Wi-Fi connection, the password for Wi-Fi connection is displayed.
2.
Use the PC or the smartphone to check that the unit is detected as a connectable wireless device.

1-8. Service Tools

Part No
J-6323-420-A
J-6325-110-A
J-6325-380-A
J-6325-400-A
J-6252-510-A
7-600-002-52
Commercially available
6
7
8
9
10
11
1
7
0
2
1
A
172
White balance value
Name
Torque screwdriver bit
Torque screwdriver bit (M1.4)
Torque screwdriver bit (M2)
Torque screwdriver (3 kg)
Torque screwdriver 6 kg
Locking compound (1401B)
Jack nut driver 3.5mm dia
Usage/Note
Tightening screws, for M2 machine screw, for M2.6 machine
screw
Tightening screws, for precision M1.4, for precision M1.7
Tightening screws, for precision M2, for precision M2.6
Tightening screws
Preventing self-loosening of screws
For 3.5 mm audio jack
16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PXW-Z190V and is the answer not in the manual?

Questions and answers

Chanuka
April 7, 2025

Sony pxw camera- What is the camera errorcode E91-390 and how do I fix it?

User image 67f3b13b83853
1 comments:
Mr. Anderson
April 9, 2025

Error code E91-390 on the Sony PXW-Z190V camera indicates a communication error from IC6000 (located on the VC-41 board) to IC2300 (also on the VC-41 board).

To fix this error:
- Check IC6000 and IC2300 on the VC-41 board.
- Inspect any connected peripheral devices.
- If the issue persists, repair or replace the VC-41 board.