1. Products are not intended and shall not be used in applications or activities which may cause death, personal injury and/or d amage
to the environment
2. Products not designed and/or intended to be used to disinfect medical devices or for medical purposes; Signify excludes any a nd all
liability for any such improper use.
3. The UV-C of this product is much stronger than normal sunlight. If you're exposed to UV-C light, it will cause a severe sunburn on
your skin, which can also damage your retina.
4. Plants and/or materials that are exposed to UV-C and/or ozone for a long time may become damaged and/or discolored.
5. Do not put valuables, such as calligraphy and painting, antiques, etc. into the disinfection chamber for disinfection. Signify is not
responsible for any related damages.
6. Children shall be supervised to ensure that they do not play with the appliance. And do not put people, animals or plants in the
chamber.
7. To avoid accidental start of UVC lamps, do not carry magnetics close to the control panel when power is on.
8. Please make sure the glass door is fully closed before start the disinfection.
9. Hard objects are prohibited to collide with the UV lamp tube and its shade.
10. If the UV lamp is damaged, it must be replaced with the Philips lamp tube.(TUV PL-L 18W/4P).
11. Please use the socket with rated current above 5A and with reliable grounding wire.
12. The power cord is Y-type connection. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons in order to avoid a hazard.
13. If it is found that the light emitted by the ultraviolet light tube can be seen directly through without any object (such as glass
brocken, etc.), the operation shall be stopped immediately and inform professional maintenance service.
14. If it is found that abnormal smell, high temperature on the housing, noise and smoke), plug must be disconnected and inform
professional maintenance service.
15. Do not disassemble and repair without permission. It must be repaired by the manufacturer or its maintenance department and
other similar professionals.
16. Do not immerse the disinfection chamber in water or spray water on it.
17. Objects shall be placed on the tray when doing disinfection.
18. The appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a pers on
responsible for their safety.
Ⅵ. Maintenance
• Do not spray water on the chamber.
• Do not let water in the vicinity of lamp holder.
• Power off during maintenance or cleaning.
• When maintenance or cleaning, open the door completely, then take out the shelf.
• External: the chamber can be cleaned with a wet towel. Strong solvents or detergents are not recommended. But neutral mild
cleaners are recommended,no residual cleaners after cleaning.
• Interior: clean the interior walls with ethanol (reagent grade) and soft towel to avoid scratching the surface. Be careful not to spray
or apply chemicals directly on the UV lamp tube. This may damage the product.
• Please maintain in strict accordance with the above requirements.
Ⅶ. Troubleshooting
Fault Phenomenon
UVC chamber does not work
UVC lamp not work
Peculiar smell in the disinfection chamber
The disinfection chamber emits smoke or
burning smell
Failed to pass UV dose verification
Note: UV lamp and ballast shall be handled according to local laws and regulations. For more information, please visit Signif y
website:https://www.lighting.philips.com/main/products/uv-disinfection/object
Possible Causes
Bad contact between plug and socket
Fuse blow
Power cord was broken
No electricity in the socket
The door is not closed
The internal components of UVC chamber are
damaged
The lamp tube is damaged
The PCB borad is damaged
Internal wiring problem
The ballast is damaged
May have protective oil smell for the first use
The Chamber is not clean
The internal components of chamber are damaged
UVC lamp tube aged
Incorrect operation
Processing Method
Plug in again
Change the fuse
Change the power cord
Check the power supply line
Close the door
Contact dealer
Contact dealer
Contact dealer
Contact dealer
Contact dealer
Clean the cavity
Clean the chamber
Contact dealer
Change the lamp tube correctly
according to the manual
Follow the instructions correctly