Page. 3 / 12 1. Overview HTMF-MF is a multipoint thermal dispersion–type gas flow meter. It enables measuring of gas flow even at an installation location where flow distribution is not even based on multipoint gas flow measurements. It is designed to have a microprocessor in the flow transmitter for high accuracy and a self-diagnosis function.
Page. 4 / 12 1.3 Terms and definitions 1.3.1 HTMF-MF This generally refers to a multipoint thermal dispersion–type flow meter. 1.3.2 Flow Meter (F/M) The F/M comprises a flow element and a flow transmitter. 1.3.3 Flow Element (F/E) The F/E, which measures actual flow, comprises a sensor element that has sensors, and a duct flange that can be attached to a duct.
(4–20 mA) for transmitting them outside the F/T. 2. Test preparations 2.1 HTMF-MF, 1 set 2.2 Multimeter, 1 EA: for checking output (4–20 mA) 2.3 Simulator, 2 EA: decade resistance box (1,000–1,500 Ω) 2.4 Performance test report: on test data of the F/E 3.
Apply power to the F/T (warm-up: 20 minutes), connect the multimeter to the output terminals, and measure the output current for checking that it is 75 mA ± 1%. Doc. no. : HTMF_Kor_2016, Rev. 0 Issued date : 2016. 11 HITROL Co., Ltd...
Page 7
60, and the default value is 30. c. CUTOFF : This is for the function that enables the user to set a certain cutoff range, such Doc. no. : HTMF_Kor_2016, Rev. 0 Issued date : 2016. 11 HITROL Co., Ltd...
Enter the resistance value of the Sa that corresponds to the output current to be checked. 5.7.2 Check that the proper output current is measured for the Sa. Doc. no. : HTMF_Kor_2016, Rev. 0 Issued date : 2016. 11 HITROL Co., Ltd...
6.2.3 Check the wired cables at regular intervals. 6.2.4 Wiring should be carried out by a qualified person. 6.2.5 Use the terminal lugs supplied by HITROL. 6.3 Precautions for installation. 6.3.1 When flanges or screws are used for fastening, the size should be the same.
7.1.4 Fasten the sensor with bolts and nuts same as bracket. 7.1.5 In case of separation, perform the above method in reverse order. <Figure1> <Figure2> <Figure3> Doc. no. : HTMF_Kor_2016, Rev. 0 Issued date : 2016. 11 HITROL Co., Ltd...
Page 11
7.2.3 Insert the product into the lower part with mounting hardware and fasten the bolts and nuts to the duct. 7.2.4 In case of separation, perform the above method in reverse order. <Figure 4> Doc. no. : HTMF_Kor_2016, Rev. 0 Issued date : 2016. 11 HITROL Co., Ltd...
Need help?
Do you have a question about the HTMF-MF and is the answer not in the manual?