Legal Notices LEGAL NOTICES LEGAL THIS DOCUMENT CONTAINS CONFIDENTIAL AND TRADE SECRET INFORMATION OF VITEC AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE OR DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE, OR SELL ANYTHING THAT IT MAY DESCRIBE.
Page 3
Legal Notices CONTACTING VITEC Monday through Friday Office Hours 9:00 AM to 5:00 PM (Pacific Time) Email http://www.vitec.com/support +1 408 739 1706 VITEC Inc. Address 931 Benecia Ave. Sunnyvale, CA. 94085 www.vitec.com EMEA (Europe, Middle East, Africa) Office Hours 9:00 AM to 5:00 PM Email support.germany@vitec.com Telephone...
Page 4
Legal Notices rEGULATIONS ANd SAFETy FS-H70 and FS-H60 comply with the following standards and country regulations: FCC Part 15 Class A This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Page 5
Legal Notices rEGULATOry COMpLIANCE rELATEd TO THE VITEC USb WI-FI AdApTEr FEdErAL COMMUNICATION COMMISSION INTErFErENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Page 6
Legal Notices In all Metropolitan departments, wireless LAN frequencies can be used under the following conditions, either for public or private use: · Indoor use: maximum power (EIRP*) of 100 mW for the entire 2400-2483.5 MHz frequency band · Outdoor use: maximum power (EIRP*) of 100 mW for the 2400-2454 MHz band and with maximum power (EIRP*) of 10 mW for the 2454-2483 MHz band dOCUMENTATION read, retain, and Follow Instructions...
Page 7
Legal Notices • Do not open batteries • Do not dispose in fire • Do not heat above 60°C (140°F) • Do not expose to water ACCESSOrIES ANd rEpLACEMENT pArTS Use only attachments and accessories recommended by VITEC. Unauthorized substitution of parts can result in loss of warranty. FS-H70 / FS-H60 Portable Recorder...
Contents LEGAL CONTACTING VITEC rEGULATIONS ANd SAFETy INTrOdUCTION 1. pHySICAL dESCrIpTION 1.1 Front View - Controls 1.2 Top View - FS-H70 Connectors 1.3 Top View - FS-H60 Connectors 1.4 Bottom View – Media and Battery QUICk STArT 1. pOWErING FS-H70 / FS-H60 2.
Page 9
Contents 1. GETTING STArTEd 1.1 Configuration requirement 1.2 First connection to FS-H70 / FS-H60 web interface 2. STATUS HEAdEr 2.1 Input Format 2.2 Record Status 2.3 Snapshot and Clips Counter 2.4 Battery Status 3. NAVIGATION pANEL 4. CONFIGUrATION pAGE 5. LIVE pAGE 5.1 Live Preview 5.2 Record Button 5.3 Pause and Stop Buttons...
Introduction INTrOdUCTION Thank you for purchasing the FOCUS FS-H60/H70 Proxy recorder. Specifically designed for video professionals, the Focus FS-H60 / FS-H70 Proxy Recorder provides easy to integrate H.264 and proxy recordings into your everyday workflow. FEATUrES • Small, Portable, Battery Powered Design •...
Introduction 1. pHySICAL dESCrIpTION 1.1 FrONT VIEW - CONTrOLS REC Button (for local record trigger) POWER Button • Short press: start/stop or (3-seconds hold resume a video recording for unit shutdown) • Long press: pause a video recording MODE Button (to select clip resolutions/bitrates and unit OK Button (for Snapshot / settings)
Quick Start QUICk STArT 1. pOWErING FS-H70 / FS-H60 FS-H70/FS-H60 can be powered using the supplied battery or directly connected to its supplied DC power adapter. Before first use in battery mode, it is recommended to fully recharge the battery: - Open the bottom compartment door.
Quick Start 3. FS-H70 / FS-H60 CONTrOLS ANd OpErATIONS 3.1 STATUS INFOrMATION By default, the Home screen displays the following information: - Clip profile selected (recording resolution and frame rate). - Device status: • NO SIGNAL: No video input signal is detected. •...
Quick Start 3.3 SETTING Up THE rECOrdING prOFILE By pressing the MODE button (short press), it is possible to select the recording profile depending on the selected wrapper/file.The following encoding profiles are available (frame rate and resolution is adjusted depending on the video input signal). MOV/Mp4 modes HD video input: resolution...
Quick Start AVCHd modes In AVCHD mode, the best available profile will be used based on the input resolution: resolution Scanning H.264 Audio bite Inputs Wrapper bit rate Audio Type Mode profile rate recorded 29.97 1.5Mb/s 1080i M2TS 1920x1080 Interlaced 8Mb/s High 2 ch.
Quick Start 3.6 pAUSE A rECOrdING To pause a recording: - Long press the REC button to pause. - To resume the recording, short press the REC button. NOTE: To stop a recording while in pause mode, long press the REC button. 3.7 OFFLOAd yOUr VIdEO ANd pICTUrES FS-H70 / FS-H60 recorders respect the camera standard providing an efficient way to ensure compatibilty for transfering the recorded content to a PC, Mac or mobile device.
Page 18
Quick Start - Select the network called FS-H70-XXXX (or FS-H60-XXXX for FS-H60) and connect to it (no password is required). NOTE: Only the VITEC Wi-Fi Adapter allow accessing the FS-H60 / H70 Web interface. NOTE: From factory, the device is configured in Ad-Hoc mode and uses an internal DHCP server to provide the IP address.
Configuring FS-H60 / FS-H70 CONFIGUrING FS-H70 / FS-H60 To access the configuration menus, press and hold the MODE button for 3 seconds (long press). 1. FS-H70 / FS-H60 MENUS The following menus are available: - FILE SETTINGS - PRE REC - RECORD CONTROL - TIMECODE - TC SUPER (only for FS-H70)
Configuring FS-H60 / FS-H70 To cycle through the menus, press the MODE button. Press OK to modify a setting or enter a menu To exit, press and hold the MODE button for 3 seconds (long press) or press the REC button. Use MODE to enter OK to select a menu and circle through...
Configuring FS-H60 / FS-H70 1.3 rECOrd CONTrOL It is possible to synchronize the start/stop of recording based on the following controls: - NOrMAL: Start/Stop recording can be triggered from the front panel REC button or via the web interface. - AUTO (only for FS-H60): recording starts and stops automatically when an active signal is detected.
Configuring FS-H60 / FS-H70 1.5 TC SUpEr (ONLy ON FS-H70) With FS-H70, TC SUPER allows the user to configure the superimposed timecode (aka VITC) onto the recorded clip. - MODE Setting: • OFF: TC SUPER is not activated • EXTERNAL: TC SUPER is activated and using the timecode from the SDI Input. •...
Configuring FS-H60 / FS-H70 1.8 dATE ANd TIME Date and Time can be set up in this menu. NOTE: A warning message is displayed at boot up when the Date/Time is reseted to default value. This message can be turned off in Date and Time menu. 1.9 NETWOrk SETTINGS To access FS-H60/H70 wirelessly, the VITEC USB Wi-Fi adapter must be used.
Configuring FS-H60 / FS-H70 1.10 prEVIEW This menu is only active if the VITEC USB Wi-FI Adapter has been plugged in prior starting up the unit. With the optional VITEC USB Wi-FI Adapter, it is possible to preview the live video input remotely while in record or not.
Page 25
Web interface Before proceeding: ENSUrE THE UNIT IS pOWErEd by THE dC pOWEr SUppLy. To prevent any power loss, inserting a charged battery is also recommended. NOTE: In case of failure during the upgrade process, the failsafe procedure must be used: - Press REC and MODE buttons simultaneously.
Web interface FS-H70 / FS-H60 WEb INTErFACE FS-H70 / FS-H60 web interface provides an easy way to manage and control your FS-H70 / FS-H60 product over a local network through a standard web browser. More details are provided in the following sections.
Web interface If FS-H70-XXXX (or FS-H60-XXXX) network cannot be found, it is likely that the unit has been configured in Infrastructure mode. To reset the network settings, access the NETWORK SETTING menu and select RESET TO DEFAULT. On next reboot, FS-H70-XXXX (or FS-H60-XXXX) network will be available. Repeat steps above to connect.
Web interface 3. NAVIGATION pANEL Live page can be used to preview the live video input and start/stop a recording or take snapshots remotely. preview page can used to review pre-recorded clips/snapshot and to download them. Control page can be used to configure the unit remotely. System page can be used to set the system parameters of the device: Date and Time, Network settings, Backlight and Web Login/Password.
Web interface 5. LIVE pAGE 5.1 LIVE prEVIEW The Live, Record and Snapshot features (and button activity) are available as long as a video input signal is detected. The video input status can be checked in the status header of the web page. - Ensure the required software is installed onto your platform (refer to section “1.1 Configuration requirement”...
Web interface 5.3 pAUSE ANd STOp bUTTONS - Pressing the pause/stop button, the recorder wil respectively pause/stop the recording in progress. - In pause mode, press the pause button to resume the recording. NOTE: The pause/stop buttons are not available from the web interface if the NETWORK SETTINGS/REC CONTROL parameter is set to OFF.
Web Interface 6. rECOrdEd CONTENT pAGE Refresh List View Selection Filter Clip Snapshot Clip name Date Clip Duration 6.1 GENErAL Refer to section 1.1 CONFIGURATION REQUIREMENT (page 16) to ensure plugins are correctly installed for your device. In RECORD mode, the recorded content is not available for playback or download. 6.2 CLIp ANd SNApSHOT WINdOW NOTE: Snapshots are sorted prior to the recorded file when taken during the recording.
Web interface 7. SySTEM prEFErENCE pAGE 7.1 dATE ANd TIME - Date can be manually set using format DD-MM-YYYY -Time can be manually set using format HH:MM:SS - Date and Time can be automatically updated using the “Insert Date and Time from PC” button NOTE: Without battery inserted, the date and time is saved for about a week.
Technical Specifications - MAC Address: Provide the MAC address of the Wi-Fi dongle Adapter - Channel: In case of poor connection in AdHoc, it is possible to change the Wi-FI channel in use. NOTE: If the Wi-Fi configuration set is incorrect and access via the web page is impossible, it is possible to reset the Wi-Fi settings to factory default using the setting RESET TO DEFAULT located in FS-H70 / FS-H60 menus (NETWORK SETTINGS).
Technical Specifications TECHNICAL SpECIFICATIONS COMpLIANCE - CE - FCC Part 15 ,Class A - C-Tick - RoHS ENVIrONMENT - Operating Temperature: +32 to 104°F (0 to 40°C) - Storage Temperature: -4 to 140°F (-20 to 60°C) - Humidity: 10-90% (relative humidity) CAUTION: FS-H70 / FS-H60 can be used in hot environments.
Page 35
Technical Specifications MEdIA SLOT - SDHC Card (compatible with card up to 32GB, Speed: Class 8 and above recommended). NOTE: FS-H60/H70 is not compatible with SDXC cards. STATUS dISpLAy - 16x2 lines character monochrome LCD Display. MOUNTING kIT - Cradle with standard 1/4“-20 screw hole •...
Warranty AVCHd modes In AVCHD, the best available profile will be used based on the input resolution. resolution Scanning H.264 Audio bite Inputs Wrapper bit rate Audio Type Mode profile rate recorded 29.97 1.5Mb/s 1080i M2TS 1920x1080 Interlaced 8Mb/s High 2 ch.
Product. Vitec Multimedia will repair or replace (at its option) any defective part during the Warranty Period, provided that (i) the Warranty remain in force. Your dated sales receipt or invoice shall be considered as the delivery date of the Product form VITEC's premises to your designated address (the "Delivery...
Need help?
Do you have a question about the FOCUS FS-H60 and is the answer not in the manual?
Questions and answers