Advertisement

инструкция по эксплуатации
UIP WIFI smart peristaltic pump
User Manual
Version:A/0
Kamoer fluid tech(Shanghai)Co., Ltd.
www.kamoer.com
www.ecounit.kz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UIP CK15 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kamoer UIP CK15

  • Page 1 инструкция по эксплуатации UIP WIFI smart peristaltic pump User Manual Version:A/0 Kamoer fluid tech(Shanghai)Co., Ltd. www.kamoer.com www.ecounit.kz...
  • Page 2: Table Of Contents

    Catalog CATALOG ............................2 QUALITY GUARANTEE ..........................3 NOTICE ..............................0 PRODUCT INFORMATION ....................... 1 ..............................1 1.1 A BOUT ............................ 3 1.2 C OPENING 2.RUNNING OPERATION ....................... 3 ..........................4 2.1 C ONTINUOUS MODE 2.2.1 Continuous mode setting ......................5 2.2.2 Continuous mode level detection setting ..................
  • Page 3: Quality Guarantee

    Quality guarantee 1.Warranty conditions Free service is limited to the warranty period under normal use and maintenance of the user's manual is valid, all due to malfunction or damage not covered under warranty. Users please take care of purchase invoices, user manual, so you can receive timely and satisfactory after-sales service.
  • Page 4: Notice

    Notice We have considered the safety of the user in the process of design of the instrument. Please read the manual carefully for installing and use of the instrument. Any improper operation may cause damage or danger. 1.Safety The product belongs to Active Products. The Operator should follow the regulation rules to avoid danger.
  • Page 5: Product Information

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Product Information 1.1 About UIP series peristaltic pump is using stepping motor control, commonly used in low traffic and high precision setting, configure the touch screen 480 x 272, powerful, easy to operate. Product appearance as shown in Figure 1-1.
  • Page 6 Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Figure 1-2 Port look Each interface definition: 1. Fan: A machine fan used to remove heat from the machine during operation; 2. Liquid level sensor interface: used to connect the liquid level sensor expansion component, so that the instrument has the function of liquid level detection;...
  • Page 7: Case-Opening

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 1.2 Case-opening  Open the package before packing, check if the packaging is damaged in the shipping process.  After you open the package, refer to the packing list in the Appendix, and verify that all components without fail, check for visible damage.
  • Page 8: Continuous Mode

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual other functions; 4. Control mode: including remote control functions such as Wi-Fi, RS485, CAN; 2.1 Continuous mode After booting up, select “Continuous Mode” in the navigation bar to enter the continuous mode control interface; in continuous mode, after clicking Start, the pump will run continuously until the stop button is clicked;...
  • Page 9: Continuous Mode Setting

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual j. Runn Volume (ml): The volume in which the continuous mode has been run. When the pump is running, the run volume continues to increase. When the continuous mode is restarted, the run volume increases from 0;...
  • Page 10: Continuous Mode Level Detection Setting

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Figure 2-2-1-2 Continuous Work Tube Setting Interface 2.2.2 Continuous mode level detection setting If the liquid level detection is on, when the pump is working, if the liquid level alarm is detected, the pump stops working and an alarm prompt is given; in continuous mode, click Set->Level Detection to enter the continuous mode level detection setting.
  • Page 11: Ration Mode

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 2.2 Ration mode After the power is turned on, clicking the Ration mode in the title bar will enter the ration mode work interface; in the ration mode, there are two working modes, namely the fully automatic working mode and the semi-automatic working mode;...
  • Page 12: Ration Mode Setting

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual this function to copy a volume first; h, working volume: display the working volume, when the ration mode starts working, the value decreases with the work of the pump, indicating the working process;...
  • Page 13: Ration Mode Level Detection Setting

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual tube type. Each tube type has a corresponding relationship between the speed and the flow rate. If not, the tube type can be performed in the system setting->tube type. calibration; b, Flow rate setting: click to set the flow rate of the ration mode;...
  • Page 14: Ration Mode Copy Volume

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Figure 2-2-2-1 Assignment mode level detection setting a, Detection switch: open and close the liquid level detection; b. Alarm type: The liquid level float has two states of floating and sinking. The state of floating and sinking of different liquid level floats is different.
  • Page 15 Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 图 2-2-3-1 分配模式复制体积 Figure 2-2-3-1 Assign mode copy volume a, Tube type: the mode of the ration mode, set in the ration mode; b, Flow rate: ration mode flow rate, set in the ration mode;...
  • Page 16: System Settings

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 2.3 System settings Figure 2-3-1 System Settings a. Tube type setting: tube type setting is used to calibrate different pump tubes; b. Wi-Fi setting: Click to set the Wi-Fi connection mode, which is divided into AP mode and router mode.
  • Page 17 Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual Figure 2-4-1 System Settings a. Tube type: the current calibrated tube model; b. Flow rate: the flow rate before calibration; c. Speed: the speed corresponding to the current flow rate; d. Calibration progress: starting from 0, when the calibration is completed, it is 100;...
  • Page 18: Wi-Fi Remote Control

    1.Apple users enter the App Store app store, Android users enter the Google Play, search for "kamoer pumps", find the app download of the corresponding icon. Kamoer Pumps App supports Android 4.4 and above, and supports iOS 9.1 and above.
  • Page 19: Ration Network

    UIP WIFI User Manual 3.2 Ration network This unit includes Wi-Fi, which can be controlled by the Kamoer Pumps App via Android or iOS phones. Before using Wi-Fi, make sure the Wi-Fi antenna on your machine is properly installed and turn...
  • Page 20 Step 5: After completing the Wi-Fi reset, the pump enters the AP Direct mode and the title bar icon changes to Step 6: The mobile phone searches for the Wi-Fi connection of KAMOER-UIP-XXXXX, and the connection password is a12345678; Step 7: Open the Kamoer Pumps App search device for control;...
  • Page 21 Step 3: Select a one-click connection in the pop-up connection mode dialog box to enter a one-click connection waiting interface; Step 4: Open the Kamoer Pumps App and follow the prompts to enter the router password input interface; Step 5: After entering the password, click the App connection. After the connection is successful, ;...
  • Page 22 Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual...
  • Page 23 Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual...
  • Page 24 Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual...
  • Page 25: App Module Introduction

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.3 App module introduction The app is divided into three functional modules, as follows: 1. Continuous mode:continuous mode title, where you can switch the allocation mode; 2. Assignment mode:Assign the mode title, where you can switch to continuous mode;...
  • Page 26 Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 1. Continuous mode: Click the title bar work mode to switch the working mode. There are two working modes, which are continuous mode and assigned mode; 2. Acceleration and deceleration granularity: set the acceleration and deceleration granularity of the flow rate, indicating the change of the flow rate when the acceleration button/deceleration button is clicked;...
  • Page 27: Continuous Mode Liquid Level Detection

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.4.1 Continuous mode liquid level detection 1. Liquid level detection: liquid level detection switch, if the liquid level detection switch is turned on, when the pump is running, if there is a liquid level alarm, the pump stops running;...
  • Page 28 Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 1. Ration mode: Click the title bar work mode to switch the working mode. There are two working modes, namely continuous mode and ration mode; 2. Operation mode and progress: The ration mode operation mode is divided into automatic and semi-automatic.
  • Page 29: Ration Mode Setting

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.5.1 Ration mode setting 1. Set the portal: Click to enter the ration mode setting interface; 2. Operation mode: Click to switch the automatic mode and semi-automatic mode; 3. Working volume: set the working volume of the ration mode;...
  • Page 30: Ration Mode Copy Function

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.5.2 Ration mode copy function The copy volume is used when the working volume that is running in the ration mode is unknown. The principle is to fill the container to be filled, how much time (volume) is needed, and then use this time to control the pump operation for filling;...
  • Page 31: System Settings

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 3.6 System settings 1. System setting entry: Click the setting in continuous mode or ration mode to enter the system setting interface; 2. Tube type setting: Click the tube type to enter the tube type calibration interface;...
  • Page 32: 4.Maintenance

    Kamoer fluid tech(Shanghai)Co., Ltd. UIP WIFI User Manual 1. Tube type: Click to enter the tube type calibration interface; 2.Start priming: Click to start Priming, click again to stop priming, when calibrating, you need to empty the air inside the pump tube;...
  • Page 33: Storage

    Please specify if there is any special application information (such as liquid). Официальный представитель компании KAMOER в Республике Казахстан - Ecounit.kz г. Нур-Султан, ул. Сембинова 11/3, 4 этаж, 13 кабинет, гостиница PORTA FORTUNA +7 (705) 544-0000 Kamoer fluid tech(Shanghai)Co., Ltd.
  • Page 34: Appendix Bpacking List

    10A AC250V User manual English Kamoer, Kamoer text and icons are registered trademarks of Kamoer Fluid Technology (Shanghai) Co., Ltd. The company reserves the right to make improvements and changes to the product's appearance and technical specifications without prior notice!