Advertisement

STAIR LIFT
INSTALLATION
MANUAL
04DEC2020 | 630-00078 REV G

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Rave 2 and is the answer not in the manual?

Questions and answers

Steve Fox
January 22, 2025

stairlift is stuck at bottom of stairs and when up switch is activated only receive a beep

1 comments:
Mr. Anderson
February 10, 2025

The AmeriGlide Rave 2 stairlift is stuck at the bottom of the stairs and beeping when the up switch is activated because it has likely stopped off the charge station. The manual states that an intermittent beep every 30 seconds indicates the lift is not on the charge station, and this repeats every 5 minutes until the lift is returned to the charge station. Moving the lift to a charge station should resolve the issue.

This answer is automatically generated

constantine gerakaris
March 24, 2025

my remotes don't work I checked the remotes are showing the indicator light but nothing happens on the lift

1 comments:
Mr. Anderson
March 24, 2025

The remotes may not be working with the AmeriGlide Rave 2 lift despite showing the indicator light because they may not be properly programmed. To ensure proper operation, reprogram both remotes by pointing them at one of the IR sensors on the chassis and pressing the "Up" or "Down" button for each remote. Additionally, check that the lift is powered on and that there are no obstructions or faults preventing operation.

This answer is automatically generated

Summary of Contents for AmeriGlide Rave 2

  • Page 1 STAIR LIFT INSTALLATION MANUAL 04DEC2020 | 630-00078 REV G...
  • Page 3: Table Of Contents

    RAVE II STAIR LIFT TABLE OF CONTENTS TABLE OF CONTENTS SAFETY .................... 4 Safety Definition ..........4 Environmental Cautions ........4 INTRODUCTION ................5 Device Name: Rave II Series ........ 5 Read and Understand .......... 5 Warranty ............. 5 Technical Specifications ........5 Code Statement ..........
  • Page 4: Safety

    If you do not understand any portion of the follows the safety alert symbol. installation or operation procedures, please consult Ameriglide's Technical Service Department at 866-378-6648. Do not attempt to install or use this WARNING lift if you have any hesitation or question. Serious...
  • Page 5: Introduction

    TECHNICAL SPECIFICATIONS RAVE II SERIES Visit Ameriglide.com for specifications on the lift Indications of Use: The Ameriglide Rave II is to assist model. the transfer of patients or mobility impaired persons up and down levels of a residence. CODE STATEMENT...
  • Page 6: Preparation

    Wood screws #14 x 2" (4 per rail bracket) Before beginning installation, inspect and check • the box contents and report any damage or missing CHAIR AND FOOTREST BOX: items to Ameriglide. Chassis • Chair with retractable seatbelt • 2 wireless call/send hand controls •...
  • Page 7: Installation

    RAVE II STAIR LIFT: SECTION 4 INSTALLATION SECTION 4 INSTALLATION DETERMINE OVERALL RAIL 4. If the top landing has restrictions (i.e. a wall or doorway), use the chart to determine the LENGTH length of extension that should be used. See Figures 4-2 and 4-3. NOTE: Use this only if the rail did NOT come precut to Extension length)
  • Page 8: Installation Site Electrical Requirements

    Locate and connect the plug on the before cutting. ends of the two power harnesses inside the two rail pieces. See Figure 4-5. Ameriglide offers a rail jig that allows holes to be drilled in the end of a rail. Contact techservices@Ameriglide.com INSTALLATION...
  • Page 9 RAVE II STAIR LIFT: SECTION 4 INSTALLATION 6. Install two (2) joint fasteners and firmly For double rails, the first rail bracket • tighten with 3/16" Allen wrench. See Figure 4-7. should be tightened in place so when turned over the back of the bracket touches the riser of the first step from the bottom landing.
  • Page 10: Zero Intrusion Installation

    RAVE II STAIR LIFT: SECTION 4 INSTALLATION clearance move the rail and bracket forward. 3. If there is an obstruction within 3.9" of the top Once the clearance is 2", tighten all bracket nose, tall brackets must be used to life the top nuts to hold the brackets in position.
  • Page 11: Chassis Installation

    RAVE II STAIR LIFT: SECTION 4 INSTALLATION CHASSIS INSTALLATION 1. Remove chassis from box. 2. Lift the chassis with the manual override hole (on bottom) facing the downhill side of the stairs and gently slide the chassis onto the rail until it makes contact with the plastic rack.
  • Page 12: Final Rail Installation

    RAVE II STAIR LIFT: SECTION 4 INSTALLATION FINAL RAIL INSTALLATION 1. Install the remaining plastic rack pieces in the upper rail. See Figure 4-18. Figure 4-20 4. Remove the charging strips from the rail box. Connect the charging strip connector to the power wire that runs through the center of the rail from the lower charging strips.
  • Page 13: Footrest And Seat Installation

    RAVE II STAIR LIFT: SECTION 4 INSTALLATION 5. Install the end plate to the top of the track FOOTREST AND SEAT with the four (4) self-cutting Torx screws using INSTALLATION the supplied T30 Torx bit. Making sure not to pinch the wires on the pigtail . 1.
  • Page 14 RAVE II STAIR LIFT: SECTION 4 INSTALLATION If the height of the seat needs to be adjusted, 8. Use the supplied white plastic plugs to secure loosen and remove the four (4) bolts on the the vertical footrest shroud to the main sides of the seat base using a 7/16"...
  • Page 15: Procedure To Switch Armrest Control From Right To Left Hand

    RAVE II STAIR LIFT: SECTION 4 INSTALLATION PROCEDURE TO SWITCH ARMREST CONTROL FROM RIGHT TO LEFT HAND 1. Turn the red "On/Off" switch located on the top of the chassis to the "Off" position. Figure 4-32 2. Flip up armrests and remove the screws on both armrests.
  • Page 16: Folding Rail Installation

    NOTE: The photos in this section shows a left folding rail, assembled to be installed on the left side of the stairway. Contact Ameriglide Technical Support at 866-378-6648 for instructions on how to switch a folding rail from the left side to the right side.
  • Page 17 This clearance is required for the stair lift footrest. In some installations, you may not be able to get 3" or more with the standard stair-bracket. Contact Ameriglide to get tall brackets. See Figures 4-40 and 4-41. Figure 4-43...
  • Page 18 RAVE II STAIR LIFT: SECTION 4 INSTALLATION Figure 4-47 13. Carefully move the fork with your hand to Figure 4-45 make sure it operates smoothly. Allow it to go all the way to the floor. Confirm that both feet 11. Adjust the height of the two feet using a 9/16" sit level on the floor and the hinge-joint is open end wrench.
  • Page 19: Completion Procedures

    RAVE II STAIR LIFT: SECTION 5 COMPLETION PROCEDURES SECTION 5 COMPLETION PROCEDURES REMOTE CONTROL 10. Connect the 6-pin and 8-pin chair wire harness to the chassis and then turn the red RE-PROGRAMMING "On/Off" switch back to the "On" position. 11. Test each remote in both the up and down All call/send controls are factory programmed.
  • Page 20: Tighten Brackets

    "On/Off" switch. Repeat the above tests. and bottom of the stairs. If any safety stop switch fails to immediately stop the lift, immediately call Ameriglide for assistance in diagnosing and repairing the problem. Do not use the lift. Install Manual...
  • Page 21: Additional System Check

    RAVE II STAIR LIFT: SECTION 5 COMPLETION PROCEDURES ADDITIONAL SYSTEM CHECK After the successful testing of all safety switches, sit on the lift and operate to the top of the stairs. Keeping the control switch pressed continuously, the lift should gently decelerate and then stop at the top of the rail.
  • Page 22: Troubleshooting

    RAVE II STAIR LIFT: SECTION 6 TROUBLESHOOTING SECTION 6 TROUBLESHOOTING MAJOR FAULTS Number of Beeps Runaway No Power Conflicting switches FOOTREST UP and FOOTREST DOWN Conflicting switches OBSTRUCTION UP and OBSTRUCTION DOWN Conflicting switches FOOTREST DOWN and OBSTRUCTION UP Conflicting switches FOOTREST UP and OBSTRUCTION DOWN Conflicting switches STOP UP and STOP DOWN switches both detected Conflicting switches STOP UP and STOP DOWN switches both NOT detected MINOR FAULTS...