Thank you for purchasing the SSA3 Indoor / Outdoor wire and wireless Siren Strobe alarm. This product will provide
you with the peace of mind and protection you expect.
The SSA3 is a combination wire and wireless Siren & Strobe Alarm. Works with traditional wire trigger from a security
control panel or as a wireless Z-Wave
when an alarm message or alert is received on any Z-Wave
The SSA3 unit WILL ALERT you from the home security panel only if correctly wired to the panel.
The SSA3 unit WILL ALERT if you have it connected to a Z-Wave network.
The SSA3 unit can be used in either way (Wire or Wireless) or BOTH at the same time.
For outdoor Use:
Unit is not recommended to be used in direct exposure to harsh elements, rain, snow, and sun.
The SSA3 is based on wireless (RF) transmissions. Any wireless transmission can be subject to RF
interference and, although unlikely, this interference may cause the SSA3 to not operate as intended. RF
transmissions will be attenuated by tinted glass, in wall isolation with metal foils, metal objects etc. Test
communication to the SSA3 before final placement. Add additional Z-Wave repeater modules to improve RF
communication if necessary. Z-Wave is a mesh network; more units, the better is the communication.
The SSA3 must not be used in life support and/or safety applications. Information provided in this document
is for your convenience and may be superseded by updates to either the document or the product. It is your
responsibility to ensure that the SSA3 meets with your specifications.

Specifications:

Power:
Distance Range:
Product Size (LxWxD):
Product Weight:
Operating Temperature:
Sound Intensity:
Anti-tamper switch:
System Requirement:
Proposed sequence for testing and installation.
SSA3 is extremely loud! Be careful when power (permanent or 9V backup) is applied. Suggested sequence
for testing and installation is: a) hold tamper switch closed, b) connect the 9V battery, c) program SSA3 into
your Z-Wave controller, d) test RF communication between your Z-Wave controller and the SSA3, e) improve
RF communication if necessary with adding additional routing Z-Wave devices, f) disconnect the 9V battery,
g) place bottom side of the siren to the permanent location, h) connect permanent power, 9V battery and
trigger wires from Security Panel GND and TAMP+ h) test your siren.

Testing the SSA3

After connecting power to the SSA3, you can test the alarm mode after manually exiting the Network Wide Inclusion (NWI) mode by pressing the
button once or after the unit is included into any Z-Wave
and remain on until the button is released. While the siren is on, it will continually cycle for 1 second off / 4 seconds on for up to 5 minutes or until it
is turned off. While the strobe is on, the unit will flash at a rate of once per second.
WARNING: THE SIREN IS EXTREMELY LOUD. WEAR EAR PROTECTION!
Using the SSA3 in a Z-Wave
The button inside the unit SW1 is used for including or excluding the SSA3 in
TM
a Z-Wave
network. Refer to your controller's User Manual for details on
network inclusion, exclusion, and association.
TM
enabled alarm device and will sound a loud siren and flash a strobe light
DC Power adapter 9V to 16V/300mA or wire from Security Panel,
Max 100ft line of sight in unobstructed environment,
Approx 200mm x 10mm x 60mm height,
500g (1 lb) total weight including power adapter,
-10ºC (14F) to +70ºC (158F)
120dB @10cm; 105dB@1m
included
TM
Any Z-Wave
enabled network and controller.
TM
enabled network. To test the SSA3, press and hold the button. The SSA3 will turn on
TM
Network
1080 Centre Rd. Suite C
Auburn Hills, MI
48326
www.fortrezz.com
SSA3
TM
enabled network.
Phone: (248) 481-7092
sales@fortrezz.com
Made in USA
18Sept2012

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SSA3 and is the answer not in the manual?

Questions and answers

Summary of Contents for FortrezZ SSA3

  • Page 1 Security Panel GND and TAMP+ h) test your siren. Testing the SSA3 After connecting power to the SSA3, you can test the alarm mode after manually exiting the Network Wide Inclusion (NWI) mode by pressing the button once or after the unit is included into any Z-Wave enabled network.
  • Page 2 Controlling the SSA3 (MultiLevel Switch Command Class or Basic Command Class) If a Z-Wave MultiLevel Switch Set or Basic Set signal with a value of 67 to 99 or 255 is received by the SSA3, the unit will sound a 117-decibel audible alarm and will flash the strobe lights. A value of 1 to 33 will turn on only the strobe lights while a value of 34 to 66 will turn on only the siren.
  • Page 3 Main Power Dropout - optional 9V battery If main power drops, the SSA3 can continue to operate on the internal 9V battery if installed, but, if triggered, will only sound the Siren for approx. 5 seconds and flash the Strobe for 30 seconds. Also, two seconds after power drops, the SSA3 will sound the siren for 5 seconds and strobe the LEDs for 30 seconds if a 9V battery is installed.
  • Page 4 Purchaser for the products which are the subject of the claims. If you are not comfortable with your limited warranty, or not completely satisfied with the SSA3, or the SSA3 does not perform as expected we encourage you to return the SSA3 to your DISTRIBUTOR for an exchange or for a full refund within 30 days of purchase.

Table of Contents