7.5
013447-101_rev-07

Exchanging the Out-feed Belt

It is recommended that the out-feed belt is replaced after
approximately 1 million coins have been counted.
a) Set the coin diameter knob to minimum.
b) Remove the right hand plastic cover.
c) Raise the out-feed belt (1).
d) Lift the feed mechanism.
e) Remove the old out-feed belt and exchange it for a new one.
f)
Replace the feed mechanism and out-feed belt.
g) Replace the right hand plastic cover.
1
1
SCAN COIN
Disassembly and Assembly
2
Lift
3
1 Out-feed belt
2 Lever
3 Coin access block
Press
down
16