Romet AdEM-PTZ Operating Manual page 39

Advanced electronic module
Table of Contents

Advertisement

the prover system being employed must be capable of accepting a high-speed pulse input from the AdEM®-PTZ (5
ms pulse width).
The following procedures can be followed for testing meters with Romet AdEM®-PTZ module:
Romet RM Imperial, LMMA Imperial and B3 Imperial AdEM®-PTZ Meters:
1. Install the appropriately sized flange connections on the prover hose
2. Connect the hose assembly to the meter flanges with a gasket to ensure an air tight fit
3. Connect the AdEM®-PTZ to the interface box on the prover with the appropriate Romet cable connector
assembly.
4. Access the Test Configuration menu and set the test parameters as follows:
Romet RM600-RM2000
LMMA 2M, B3 2M
Prover:
Test connection:
Meter output:
Pulse/test:
select:
Test volume: select
AdEM®-PTZ
pulse
The remainder of the Test Configuration menu can be completed in the normal manner.
5. Enter the Proving mode (refer to Section 4, Security for entering the access password) and select the pulse
weight to match the pulse weight for the prover test configuration.
6. Perform the proving test in the normal manner with AdEM®-PTZ in Proving Mode.
7. Disconnect the Romet cable assembly and the flange connections after completing the test.
Romet G & RM Metric AdEM®-PTZ Meters:
1. Install the appropriately sized flange connections on the prover hose
2. Connect the hose assembly to the meter flanges with a gasket to ensure an air tight fit
3. Connect the AdEM®-PTZ to the interface box on the prover with the appropriate Romet cable connector
assembly.
4. Access the Test Configuration menu and set the test parameters as follows:
Romet RM16-RM55
Romet G10-G40
Prover:
Test connection:
Meter output:
Pulse/test:
select 10
Test volume:
AdEM®-PTZ pulse
The remainder of the Test Configuration menu can be completed in the normal manner.
5. Enter the Proving mode (refer to Section 4, Security for entering the access password) and select the pulse
weight to match the pulse weight for the prover test configuration.
6. Perform the proving test in the normal manner with AdEM®-PTZ in Proving mode.
Disconnect the Romet cable assembly and the flange connections after completing the test.
ROMET LTD.
AdEM™-PTZ
Romet RM3000-RM11000
LMMA 3M-11M, B3 3M-11M
2M
Prover:
opto
Test connection:
UNC
Meter output:
50
Pulse/test:
Test volume: select
50
1 cf
ADEM®-PTZ pulse
Romet RM85-RM200
2M
Prover:
opto
Test connection:
UNC
Meter output:
Pulse/test:
select 1
Test volume:
3
0.1 m
AdEM®-PTZ pulse
Romet RM16000-RM56000
LMMA 16M, B3 16M
10M
opto
UNC
select:
10
100
10 cf
Romet G65-G160
10M
opto
UNC
select 10
select 1
3
0.1 m
Prover:
10M
Test connection:
opto
Meter output:
UNC
Pulse/test:
select:
10
Test volume: select
1000
AdEM®-PTZ
pulse
100 cf
Romet RM300-RM1600
Romet G250-G1000
Prover:
10M
Test connection:
opto
Meter output:
UNC
Pulse/test:
select 10
Test volume:
select 10
AdEM®-PTZ pulse
1 m
3
36