Page 1
User Manual All rights reserved. Specifications are subject to change without notice.
Page 2
LIMITED WARRANTY AND LIMITATION OF LIABILITY Customers enjoy one-year warranty from the date of purchase. This warranty does not cover fuses, disposable batteries, damage from misuse accident, neglect, alteration, contamination, or abnormal conditions of operation or handling, including failures caused by use outside of the product's specifications, or normal wear and tear of mechanical components.
Introduction This product is a 9999 counts true RMS auto- ranging digital multimeter. It is operated all by buttons with a triple display. Safety Information To avoid possible electrical shock, fire, or personal injury, please read all safety information before you use the product. Please use the product only as specified, or the protection supplied by the product can be compromised.
Page 6
• Keep fingers behind the finger guards on the probes. • When the product has already been connected to the line being measured, do NOT touch the input terminal that is not in service. • Disconnect the test leads from the circuit before changing the mode.
Instrument Overview LCD Display Auto range. The product selects ① the range with the best resolution. Manual range. The user selects ② the range. ③ Capacitance test. (Farad) ④ Relative mode. ⑤ Diode test. ⑥ Continuity test. ⑦ Duty cycle test. ⑧...
Page 8
⑪ Frequency test. (Hertz) ⑫ Temperature test. (Celsius) ⑬ Temperature test. (Fahrenheit) ⑭ Analog bar graph. ⑮ Resistance test. (Ohm) ⑯ Current test. (Ampere) ⑰ Voltage test. (Volt) ⑱ Primary measurement display. product measures both ⑲ sinusoidal and nonsinusoidal ac waveforms accurately.
Function Buttons ② ③ ① ④ Short press to switch among functions. ① Long press to enter in V.F.C function. Short press to change range. Push for more than 2 seconds to enter the relative mode. The product will store the present ②...
Rotary button Turn off the product at this position. • The product automatically powers off after 15 minutes of inactivity. • The built-in beeper beeps 5 times 1 minute before auto power off. • To restart the product from auto power off, press the SELECT button or turn the rotary switch back to the OFF position and then...
Page 11
AC voltage ≤750V DC voltage ≤1000V Frequency ≥10V,1~100KHz Duty cycle:1%~99% V.F.C AC voltage ≤99.99mV DC voltage ≤99.99mV Frequency ≤10V,1~10MHz Duty cycle :1%~99% Temperature:-20~1000°C (-4~1832)℉ Resistance:≤99.99MΩ Continuity:beeper will beep when resistance less than 50 Ω Diode test. Displays above 3V Capacitance:≤9.999mF Square wave:...
Input Terminals Input terminal AC/DC current measurements to 9.999A. Input terminal AC/DC current μA/mA measurements to 99.99mA. Common (return) terminal measurements. Input terminal for the measurements of: 1. Diode 2. Continuity 3. Square wave 4. Temperature 5. AC/DC voltage 6. Resistance 7.
Measurements Instruction Measure AC/DC Voltage 1. Connect the black test lead to the COM Terminal and the red lead to the Terminal. 2. To measure voltage under 99.99mV, turn the rotary to .To measure voltage higher than 99.99mV, turn the rotary to , press SELECT to turn to AC voltage test mode.
*Do not measure current that exceeds the extremes as indicated in the Specifications. *Use the AmA Terminal when you are measuring an unknown current. Then switch to the μA Terminal if necessary. *Do not input voltage at this setting. Measure Resistance 1.
4. To test diodes, connect the red probe to the anode side and the black probe to the cathode side of the diode being tested. Then read the forward bias voltage value on the display. If the polarity of the test leads is reversed with diode polarity or the diode is broken, the display reading shows “...
Measure Frequency and Duty Cycle 1. Connect the black test lead to the COM Terminal and the red lead to the Terminal; 2. Turn the rotary switch to , press SELECT to frequency test function (≥10V,1~100KHz); or turn the rotary switch to , press SELECT to frequency test function (≤10V,1~5MHz);...
Measure Temperature 1. Connect the black test lead to the COM Terminal and the red lead to the Terminal; , press “SELECT” to 2. Turn the rotary to the temperature Mode; Now the main display will show Celsius and the vice display will show Fahrenheit;...
Measure V.F.C 1. Connect the black test lead to the COM Terminal and the red lead to the Terminal; 2. Turn the rotary to , long press to enter V.F.C mode, the screen will show voltage when put the test leads at the correct circuit. Measure square wave 1.
Maintenance Beyond replacing batteries and fuses, do not attempt to repair or service the product unless you are qualified to do so and have the relevant calibration, performance test, service instructions. Clean the Product Wipe the product with a damp cloth and mild detergent.
2. Loosen the screw on the battery door and remove the battery door. 3. Replace the used batteries with new batteries of the same type. 4. Place the battery door back and fasten the screw. Replace the Fuses When a fuse is blown or do not work properly, it shall be replaced as below: 1.
Specifications General Specifications 9999 Counts Display(LCD) Ranging Auto/Manual Material ABS+TPE Update Rate 3 Times/Second Ture RMS √ Data Hold √ Backlight √ Low Battery Indication √ Auto Power Off √ Mechanical Specifications 147*76*37mm Dimension Weight 191g(without batteries) Battery Type 1.5V AAA Battery * 3 Warranty One year Environmental Specifications...
Electrical Specifications Function Range Resolution Accuracy 999.9mV 0.1mV 9.999V 0.001V DC Voltage 99.99V 0.01V ±(0.5%+3) 999.9V 0.1V 9.999mV 0.001mV DC Voltage (mV) 99.99mV 0.01mV 999.9mV 0.1mV 9.999V 0.001V AC Voltage 99.99V 0.01V ±(1.0%+3) 750.0V 0.1V 9.999mV 0.001mV AC Voltage (mV) 99.99mV 0.01mV *Frequency response of ACV: 40Hz-1kHz...
Page 23
Function Range Resolution Accuracy 9.999A 0.001A DC Current (A/mA) 999.9mA 0.1mA 99.99mA 0.01mA ±(1.0%+3) 9.999mA 0.001mA DC Current (μA/mA) 99.99μA 0.01μA 999.9μA 0.1μA 9.999A 0.001A AC Current (A/mA) 999.9mA 0.1mA 99.99mA 0.01mA ±(1.2%+3) 9.999mA 0.001mA AC Current (μA/mA) 99.99μA 0.01μA 999.9μA 0.1μA Frequency response of AC Current: 40Hz-1kHz...
Need help?
Do you have a question about the SZ18 and is the answer not in the manual?
Questions and answers