ABBATTITORE 15/20 TEGLIE
15/20 TRAYS BLAST CHILLER
TOUCH
S1: INTERRUTTORE BIPOLARE.
C: COMPRESSORE (ML.TB).
M1/M2: MOTORE PER VENTOLE
CONDENSATORE.
M3: MOTORE PER VENTOLE SUPPLE-
MENTO CONDENSATORE.
M4: MOTORE PER VENTOLE SU CONDENSA-
TORE E RAFFREDDAMENTO COMPRESSORE.
V1/V2/V3: MOTORE PER VENTOLE SU
EVAPORATORE.
RP1: RESISTENZA INTERNA ALLA
PLASTICA DI BORDO PORTA.
KC: RELÈ PER ALIMENTAZIONE
COMPRESSORE.
KVE: RELÈ PER ALIMENTAZIONE
VENTOLE SU EVAPORATORE.
MC: INTERRUTTORE PORTA APERTA.
S-CO1/S-CO2: SONDA DI
CONTROLLO SURRISCALDAMENTO
CONDENSATORE.
S-C: SONDA NELLA CAMERA REFRI-
GERATA PTC.
S-S: SONDA SPILLONE PTC PER LA TEMPERATU-
RA INTERNA DELL'ALIMENTO DA ABBATTERE.
C1/C2/C3: CONDENSATORE DI SPUNTO PER
VENTOLA INTERNA DA 1 MICROFARAD
R2: RESISTENZA INTERNA COMPRESSORE.
PR: PRESSOSTATO HP
F1: INTERRUTTORE MAGNETOTERMICO
WBC1433: SCHEDA CONTROLLO
K1: RELÈ ALIMENTAZIONE RESISTEN-
ZA COMPRESSORE
S1: BIPOLAR SWITCH
C: COMPRESSOR (ML.TB)
M1/M2: CONDENSER FAN MOTOR
M3: FAN MOTOR, ADDITIONAL
CONDENSER
M4: FAN MOTOR ON CONDENSER
AND COMPRESSOR COOLING
V1/V2/V3: FAN MOTOR ON
EVAPORATOR
RP1: INTERNAL HEATER ON DOOR
FRAME PLASTIC
KC: RELAY FOR COMPRESSOR SUPPLY
KVE: RELAY FOR EVAPORETOR
FANS SUPPLY
MC: OPEN DOOR SWITCH
S-CO1/S-CO2: CONSENSER
OVERHEATING PROBE
S-C: PTC PROBE IN THE REFRIGERATED ROOM
S-S: PTC CORE PROBE FOR THE INTERNAL
TEMPERATURE OF THE FOOD TO BE BLASTED
C1/C2/C3: CONDENSER FOR THE
INTERNAL FAN IN 2 MICROFARAD
R2: CONDENSER INTERNAL HEATER
PR: HP PRESSURE SWITCH
F1: SWITCH MAGNETERMIC
WBC1433: CONTROL PANEL
K1: COMPRESSOR POWER SUPPLY RELAY
Appendici | Manuale d'uso e manutenzione | IT - EN - F - DE - ES - ARABIC
143
Need help?
Do you have a question about the Attila Series and is the answer not in the manual?
Questions and answers
display pcb wiring diagram
Only the freezer mode was working the chiller mode was not working
@Amshith if i put chiller mode againg its working with freezer
The chiller mode on the Tecnodom Attila Series may not be working due to several reasons:
1. Room Probe or Condenser Probe Error (Er2 or Er3): Cables may be disconnected. Ensure all cables are properly inserted and secured in the terminal.
2. Evaporator Blocked with Ice: Ice buildup may block airflow. Leave the door open for at least 15 minutes to melt the ice.
3. Overloaded Trays or Grills: Excess product may impact cooling. Reduce the load.
4. Internal Fan Not Spinning: If the fan is not working, contact assistance.
5. High Room Temperature or Humidity: Environmental conditions can affect performance. Contact assistance if the room is too hot or humid.
6. Door Not Properly Closed: If the door is open, the unit may not function correctly. Ensure the door is shut tightly.
If these checks do not resolve the issue, contact technical assistance.