6. Error Codes
Code
Reason / Solution
Thermistor is Unplugged
ERR1
- Contact EvaKool
Thermistor is Short Circuited
ERR2
- Contact EvaKool
Low Voltage
• Please check the source voltage to ensure it is above the cut out . Try
E1
• The vehicle cabling may be inadequate/unsuitable, please refer to
• Try on a different power source .
Fan Issue
E2
• Fan is drawing too many Amps (Over 1 Amp) .
- Contact EvaKool
Compressor Start Issues
• Unplug for 10 minutes .
E3
• Try on a different power source .
• Possible Electronic Box or compressor fault .
- Contact EvaKool
The Compressor Speed is Too Low
• Unplug for 10 minutes .
E4
• Reduce product load inside unit .
• Move unit to a lower ambient temperature .
• Clean vents / ensure clear air flow over compressor .
Ambient Temperature Too High
• Clean vents / ensure clear air flow .
E5
• Fan fault .
- Contact EvaKool
lowering the voltage cut out setting to LOW .
cable specifications table for correct cable thickness (page 5) .