SMC Networks PF2M7 Series Manual

Digital flow switch
Hide thumbs Also See for PF2M7 Series:

Advertisement

2-Color Display
Digital Flow Switch
Applicable fluid
A wide range of flow measurement is possible with 1 product.
100: 1
*
2
Flow ratio
Port
0.02
size
0.1
0.01 0.05
0.01
PF2M701
New
New
0.02
PF2M702
New
New
C4
/
3
C6/
1
0.05
PF2M705
New
New
PF2M710
PF2M725
C6/
1
PF2M750
C8/
PF2M711
2
The flow rate value and the device status can
be figured out easily via the process data.
4
PF2M7-L
p.
Series
Over current error, Outside of rated flow
Diagnosis
range, Accumulated flow error, Internal
items
product malfunction
Compatible with argon (Ar) and
Made to order
carbon dioxide (CO
Improved resistance to moisture
and foreign matter
The bypass construction reduces sensor accuracy
deterioration and damage.
* There is no bypass construction for the 1 and 2 L ranges.
Compact, Lightweight
Length
Height
4.7
4.5
/
mm
Weight
27.3
lighter
%
* Port size: ø6
PF2M7(-L)
Dry air, N
, Ar, CO
2
2
*2 Excludes the PF2M725 *3 Made to order (Produced upon receipt of order)
0.3 0.5
1
2
3
1
2
5
0.1
0.3
0.5
1
Compatible
23
p.
) mixed gas
2
1
p.
1
p.
mm
shorter
Series
Flow range [L/min]
5
10
25
10
25
Female thread piping has
been added.
Female thread: 1/8, 1/4 (Rc, NPT, G)
®
RoHS
*1 For the PF2M7-L
Smallest settable
increment
50
100
0.001
0.01
50
0.1
100
CAT.ES100-127B
*1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PF2M7 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for SMC Networks PF2M7 Series

  • Page 1 2-Color Display ® Digital Flow Switch RoHS Applicable fluid Dry air, N , Ar, CO *1 For the PF2M7-L A wide range of flow measurement is possible with 1 product. 100: 1 Flow ratio *2 Excludes the PF2M725 *3 Made to order (Produced upon receipt of order) Port Flow range [L/min] Smallest settable...
  • Page 2 PF2M7(-L) Digital Flow Switch 2-Color Display Series Improved resistance to Compact, Lightweight moisture and foreign matter 27.3 lighter Weight (55 g The bypass construction reduces the moist air or PF2M7 foreign matter in contact with the sensor, reducing sensor accuracy deterioration and damage. Sensor unit g h t H e i...
  • Page 3 PF2M7(-L) Digital Flow Switch 2-Color Display Series The digital display allows for the Select a model according to the fluid to be used. visualization of the flow rate. Dry air, 2-color display, Improved visibility Nitrogen Carbon Argon dioxide (Ar) Recommended pneumatic circuit examples Compressed air line Vacuum line Vacuum line...
  • Page 4 PF2M7(-L) Digital Flow Switch 2-Color Display Series Select a digital flow switch to increase energy savings! Main line flow control Flow control is necessary for promoting en- ergy saving in any application. Saving energy starts from numerical control of the flow consumption of equipment and lines and clarification of the purpose and effect.
  • Page 5 PF2M7(-L) Digital Flow Switch 2-Color Display Series IO-Link Compatible PF2M7mm-m-Lm-mmm Supports the IO-Link communication protocol IO-Link is an open communication Configuration File (IODD File * interface technology between the sensor/ actuator and the I/O terminal that is an · Manufacturer · Product part no. international standard: IEC61131-9.
  • Page 6 Flow Switch Flow Rate Variations Rated flow range [L/min] Applicable Detection Series fluid method −3 −2 −1 −0.5 PFMV Thermal Dry air type (MEMS) −0.5 −1 −3 Series Rated flow range [L/min] Smallest Applicable Detection settable Compatibility with the fluid method 0.02 0.1 0.3 0.5...
  • Page 7 Flow Switch Variations / Basic Performance Table PFMV PF2M7(-L) PFMB PFMC PF2A PF3A7„H PFMV3 PFG300 PFG300 PFG300 IP65 IP65 IP40 IP40 IP40 IP65 [Monitor unit IP40] [Monitor unit IP40] Dry air, Dry air, N Dry air, N Dry air, N Air, N Air, N , Ar, CO...
  • Page 8: Table Of Contents

    C O N T E N T S PF2M7(-L) Digital Flow Switch 2-Color Display Series How to Order ....................p. 9 Specifications ..................pp. 11, 12 Set Point Range and Rated Flow Range ............. p. 13 Flow/Analog Output ..................p. 13 Pressure Loss (Reference Data): Without Flow Adjustment Valve ....
  • Page 9: How To Order

    ® Digital Flow Switch 2-Color Display RoHS PF2M7 Series How to Order PF2M 7 10 Integrated display y u i Rated flow range Port size Piping variations 0.01 to 1 L/min Rated flow range With One-touch fitting Female thread Symbol Port size 01, 02, N1, N2, 0.02 to 2 L/min , C6, C8...
  • Page 10 ® Digital Flow Switch 2-Color Display RoHS PF2M7-L Series How to Order PF2M 7 10 C6 L Integrated display y u i Made to order (Refer to page 23.) Rated flow range Port size Piping variations 0.01 to 1 L/min Rated flow range With One-touch fitting Female thread...
  • Page 11: Specifications

    PF2M7(-L) Series For flow switch precautions and specific product precautions, refer to the Operation Manual on the SMC website. Specifications PF2M701(-L) PF2M702 (-L) PF2M705 (-L) PF2M710 (-L) PF2M725 (-L) PF2M750 (-L) PF2M711(-L) Model Applicable fluid * Dry air, N , Ar, CO (JIS B 8392−1 1.1.2 to 1.6.2, ISO 8573−1 1.1.2 to 1.6.2) Fluid temperature range 0 to 50°C...
  • Page 12 PF2M7(-L) Series Digital Flow Switch 2-Color Display *1 Refer to the “Recommended pneumatic circuit examples” on page 2. *10 When selecting 0 to 10 V, refer to the analog output graph for the allowable *2 When using the accumulated value hold function, use the operating load current.
  • Page 13: Set Point Range And Rated Flow Range

    PF2M7(-L) Series Set Point Range and Rated Flow Range Set the flow rate within the rated flow range. The set point range is the range of flow rate that can be set in the switch. The rated flow range is the range that satisfies the switch specifications (accuracy, linearity, etc.). It is possible to set a value outside of the rated flow range if it is within the set point range, however, the satisfaction of specifications can not be guaranteed.
  • Page 14: Pressure Loss (Reference Data): Without Flow Adjustment Valve

    PF2M7(-L) Series Digital Flow Switch 2-Color Display Pressure Loss (Reference Data): Without Flow Adjustment Valve PF2M701(-L) PF2M702 (-L) 1 L/min 2 L/min –70 kPa 750 kPa 350 kPa 350 kPa –30 kPa 750 kPa –30 kPa 0 kPa 0 kPa –50 kPa –50 kPa –70 kPa...
  • Page 15: Flow Rate Characteristics At Negative Pressure (Reference Data)

    PF2M7 ( -L ) Series Flow Rate Characteristics at Negative Pressure (Reference Data) When the PF2M series is used with negative pressure (–70 to 0 kPa), the measurable range (warranty range of the specifications including pressure characteristics) varies depending on the flow range. Select the flow range referring to the graph below.
  • Page 16: Internal Circuits And Wiring Examples

    PF2M7(-L) Series Digital Flow Switch 2-Color Display Internal Circuits and Wiring Examples NPN + NPN output type PNP + PNP output type PF2M7 PF2M7 Brown Brown DC (+) DC (+) Brown Brown DC (+) DC (+) Black Black OUT1 OUT1 Black Black OUT1...
  • Page 17 PF2M7(-L) Series Internal Circuits and Wiring Examples PF2M7 NPN output type PNP output type Brown DC (+) Brown DC (+) Black OUT1 Black OUT1 18 to 30 VDC 18 to 30 VDC − − White N.C. White N.C. Blue DC (−) Blue DC (−) Max.
  • Page 18: Construction: Parts In Contact With Fluid

    PF2M7(-L) Series Digital Flow Switch 2-Color Display Construction: Parts in Contact with Fluid PF2M701/702/705/710/725/750/711(-L) w q e r t y u i o r Female thread PF2M705/710/725/750-C4/C6 (-L) PF2M711-C8 (-L) PF2M701/702 (-L) PF2M711S (-L) * There is no bypass construction for the 1 and 2 L ranges. Component Parts Description Material...
  • Page 19: Dimensions

    PF2M7(-L) Series Dimensions PF2M7m-C4/C6/C8 (-L) OUT1 OUT2 10.2 DC(–) DC(+) 2 x One-touch fitting 2 x 3.4 Applicable tubing O.D.: ø4, ø6, ø8 [mm] Model PF2M701/702/705/710 59.1 ø2.8 depth 8.4 -C4 (-L) PF2M701/702/705/710/ 59.9 ø2.8 depth 8.4 725/750-C6 (-L) PF2M711-C8 (-L) ø2.8 depth 6.2 PF2M7m-m1/2 (-L) OUT1...
  • Page 20 PF2M7(-L) Series Digital Flow Switch 2-Color Display Dimensions PF2M7mS-C4/C6/C8 (-L) OUT1 OUT2 10.2 DC(–) DC(+) 2 x One-touch fitting 2 x 3.4 Applicable tubing O.D.: ø4, ø6, ø8 [mm] Model PF2M710S-C4 (-L) 87.1 ø2.8 depth 8.4 ø2.5 depth 6 PF2M710/725/750S 87.9 ø2.8 depth 8.4 ø2.5 depth 6...
  • Page 21 PF2M7(-L) Series Dimensions PF2M701/702/705/710/725/750/711(-L) Panel mounting/Without flow adjustment valve/Straight Panel mounting/With flow adjustment valve/Straight 78.0 Panel Fitting Dimensions Panel Fitting Dimensions 120 or more ∗ 120 or more ∗ +0.5 +0.5 4 x R3 or less 4 x R3 or less 4 x R3 or less 4 x R3 or less 4 x R3 or less...
  • Page 22 PF2M7(-L) Series Digital Flow Switch 2-Color Display Dimensions PF2M701/702/705/710/725/750/711(-L) DIN rail mounting bracket ZS-33-R 18 x n pcs. + 34.4 DIN rail AXT100-DR- * For m, enter a number from the No. line in the table below. 12.5 5.25 (Pitch) 1.25 L Dimensions [mm] 35.5...
  • Page 23: Made To Order

    PF2M7-L Compatible Products Series Made to Order Please contact SMC for detailed specifications, delivery times, and prices. Symbol X731 Compatible with Argon (Ar) and Carbon Dioxide (CO ) Mixed Gas The argon–carbon dioxide gas ratio (Ar : CO ) can be selected using the push-buttons from among the following: 92 : 8, 90 : 10, 80 : 20, 70 : 30, 60 : 40, 40 : 60, and 30 : 70.
  • Page 24: Function Details

    PF2M7(-L) Series Function Details For setting of functions and operation method, refer to the Operation Manual from the SMC website Documents/Download --> Instruction Manuals.  Output operation  Forced output function The output operation can be selected from the following: The output is turned on/off in a fixed state when starting the system Output corresponding to instantaneous flow (Hysteresis mode, or during maintenance.
  • Page 25 PF2M7(-L) Series  Analog free span function This function allows a flow that generates an output of 5 V (or 10 V when 0 to 10 V is selected) or 20 mA to be changed. The value can be changed between 10% of the maximum value of the rated flow and the maximum value of the display range. For analog voltage output of 0 to 10 V Can be changed Can be changed...
  • Page 26: Safety Instructions

    These safety instructions are intended to prevent hazardous situations and/or Safety Instructions equipment damage. These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.” They are all important notes for ∗1) safety and must be followed in addition to International Standards (ISO/IEC) and other safety regulations.

Table of Contents

Save PDF