CONDENSATE SWITCH MONITOR INSTALLATION GUIDE
• Ensure proper operation of HVAC system, following manufacturer's instructions
This guide describes installation and activation of the Sensi Predict
Monitor accessory. The accessory provides indication of system shutdown by condensate level
switches responding to excessive water levels. One or more switches may be monitored.
To install, connect the free wires of the condensate switch monitor to either end of the
condensate switch chain as shown below. Plug the connector into one of the accessory ports
of the Sensi Predict Data Hub and ensure that the red stripe on the 3-pin connector side of the
wire is facing up, as illustrated below. See back for validation procedure.
CONDENSATE SWITCH MONITOR CONNECTIONS
TO CONDENSATE SWITCH S
CONDENSATE
SWITCH WIRES
BEFORE INSTALL
TO CONDENSATE SWITCH S
CONDENSATE
SWITCH WIRES
The Sensi Predict PRO Portal can be accessed at sensipredictpro.com
For login support, contact your office administrator.
For support within the PRO Portal, call 1-877-424-1715.
ELECTRICAL SHOCK/FIRE HAZARD
• Installer must be qualified technician
• Connect only to a 24 volt class 2 circuit
• Follow all local and national codes and ordinances
NOTE: Please verify that the condensate switch is rated
R,C, OR Y
CONTROL WIRE
to control the connected load.
NOTE: The condensate switch monitor MUST be wired
in parallel
Ensure that the red stripe on the 3-pin connector side
R,C, OR Y
of the wire is facing up, as shown above
CONTROL WIRE
WARNING
R,C, OR Y
CONTROL WIRE
CONDENSATE
SWITCH MONITOR
R,C, OR Y
CONTROL WIRE
™
Condensate Switch
INDOOR DEVICE
0037-7658001
Need help?
Do you have a question about the Sensi Predict and is the answer not in the manual?
Questions and answers