  • Page 1 BF-430 User Manual Document Version 1.0 Web Version realcom 2009-02-07 Firmware Version 1.13.00,Apr 4 2011...
  • Page 2: Table Of Contents

    【Index】 Ⅰ、Hardware Introduction......................1 Ⅱ、Product Overview........................3 Ⅲ、WEB Login ..........................4 Ⅳ、Web Function Instruction ....................10   One Page Quick Setup......................10   Advanced Setup........................13 1、Operation Mode Setup ..................13 (1)TCP Server .......................13 (2)TCP Client......................14 (3)UDP Server .......................15 (4)UDP Client ......................16 2、Serial Port Setup ....................17 3、DDNS Setup......................18 (1)TZ0........................18 (2) Dyndns ......................19  ...
  • Page 3: Ⅰ、Hardware Introduction

    Signal Port RS232/485/422 RS232 Signal TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND, Baud Rate:1200bps~230.4kbps RS485 Signal 2 wire Data+/- (only for BF-430) RS422 Signal 4 wire R+/R-/T+/T- (only for BF-430) 16 bit CPU, 100MHz Memory 256K ROM & 768K SDRAM...
  • Page 4  End point - 2 -...
  • Page 5: Ⅱ、Product Overview

    Real time operation system and complete TCP/IP protocol enable CHIYU’s BF-430 powerful converter not only providing complete system with highly efficiency but also able to link with network. Easy to install and wire. The Web interface of BF-430 is simple, easily to operate, and without operation system limitation.
  • Page 6: Ⅲ、Web Login

     Preparation Before conducting BF-430 setting, please assure the following:  PC has connected to BF-430, and PC and BF-430 are situated in the same WAN with power supplied.  If the default IP address (192.168.168.125 )
  • Page 7 3、While the IP Search window shows up, it will display all BF-430 in LAN, and show its Device name, Location, Model Name, Address, Subnet Mark, Gateway, Address. Select particular BF-430, then its related information will appear below the window, as shown: 4、The showed information of BF-430 can be revised directly in the window, the part can...
  • Page 8 WAN, if want to get access into the Web of BF-430, has two methods: (1)Open IP Search, select and double click particular BF-430, then to enter its webpage. (2)While the internet explorer opened, input BF-430 IP address to enter its webpage Remark:...
  • Page 9 , open and search for , click Alter Interface Card on the upper-left side. 《Step 2》 Click LAN link, select content, then the LAN settings will be shown, click Internet Protocol(TCP/IPv4) , then input the same setting as BF-430, as below figure: - 7 -...
  • Page 10  How to login to BF-430 Web via web browser 1、Start Web browser ( ig: WIN 7 IE ), input BF-430’s IP Address, for example: use the default BF-430 IP Address: http://192.168.168.125 2、If connection failed, should check:  If BF-430 installed and its power supplied properly ...
  • Page 11 3、If the connection with BF-430 is successful, then it will display a message window for User name and Password, the default for user name and Password is: admin/admin, as shown below: 4、While the user name and password entered, a Web setting interface of BF-430 will be showed, enter it will then display a “...
  • Page 12: Ⅳ、Web Function Instruction

     One Page Quick Setup  Function instruction of STATIC IP Function Description ,default setting is 192.168.168.125 IP Address BF-430 Set the IP address of the Subnet mask BF-430 ,default setting is 255.255.255.0 Set the subnet mask of the Gateway BF-430 ,default setting is 192.168.168.254...
  • Page 13 Function instruction of DHCP CLIENT Function Description Host Name (optional) Fill in the host name , default setting is CHIYU (optional) Serial Port Mode Set the serial type, RS232 and RS485 for setting , default setting is Serial Type RS232 1.Set serial port baud rate, the parameters can be selected:1200、...
  • Page 14  Default setting is 0 second, the range is from 0 ~ 4294967295 Close Connection when  Keep the connection of BF-430 and ISP always must set the no into Idle Time Over 0 or the connection with PPPoE will be disabled when Idle time over.
  • Page 15: Advanced Setup

    The maximum TCP connection is 4 sets , default setting is 1 Max TCP Connection When using the Virtual COM, if you need BF-430 with VCOM to send each other RTS / CTS, DTR / DSR signal, this option must...
  • Page 16: Tcp Client

    Remote Host IP Address Set remote host IP address,default setting is 0.0.0.0  There are 2 modes to set TCP connection to server: BF-430 1.Start Up:This mode means when enable, it will build the TCP connection with SERVER immediately. It...
  • Page 17: Udp Server

    (3)UDP Server  Function instruction Function Description  If data transmit thru UDP remote command, must select Serial Server Mode into UDP SERVER and set LISTEN Local Listen Port Number PORT NUMBER into the same value with monitoring side.  Default setting is 50000 - 15 -...
  • Page 18: Udp Client

    (4)UDP Client  Function instruction Function Description Set the remote connection port number ,the range is 0 ~ Remote Connection Port Number 65535,default setting is 50000 Remote Host IP Address Set the remote host IP address, the default setting is 0.0.0.0 - 16 -...
  • Page 19: 2、Serial Port Setup

     Set the transmission data end by identified delimiter and if your transmission data Delimiter 1 includes the identified delimiter, BF-430 will send out packet at once.  Default setting is disabled. The range is from 0x00 ~ 0xFF  Set the transmission data end by identified delimiter and if your transmission data Delimiter 2 includes the identified delimiter, BF-430 will send out packet at once.
  • Page 20: 3、Ddns Setup

    3、DDNS Setup (1)TZ0  Function instruction Function Description E-mail Address Fill in the E-mail address for DDNS , up to 47 characters Fill in the password key for DDNS , up to 31 characters Password key Fill in the device DNS name ,...
  • Page 21: Dyndns

    (2) Dyndns  Function instruction Function Description for DDNS ,up to 31 characters Username Fill in the username for DDNS ,up to 31 characters Password Fill in the password Device DNS Name Fill in the device DNS name,for example:hostname.dyndns.org Display the registry IP address,when DDNS is enabled, It will show the Registry IP Address registry IP address Display DNS Serve status,when DDNS server does not enable ,it will show...
  • Page 22: Management

    Display and set the device management IP address , default setting is Address 192.168.200.200 Device Hostname Fill in the device hostname, default setting is CHIYU Device Location Fill in the device location , default setting is blank  User Name:Fill in the user name ...
  • Page 23: 2、System Status Monitor

    Subnet mask Display BF-430 Subnet mask, default setting is 255.255.255.0 Default Gateway Display BF-430 Default Gateway, default setting is 192.168.168.254 Primary DNS Display BF-430 Primary DNS address, default setting is 168.95.1.1 STATUS Display BF-430 internet status Serial Status Serial Type...
  • Page 24: 3、Backup & Restore Configuration

    3、Backup & Restore Configuration  Function instruction Function Description After execution, can save the present system settings as a backup file, and save it in Backup hardware, the sub-name of the saved file is .cfg Restore Browse and select saved file( .cfg ), execute Restore to restore system settings - 22 -...
  • Page 25: 4、Firmware Upgrade

    4、Firmware Upgrade  Function instruction Function Description  Browse and select firmware, execute Upgrade to upgrade firmware  Please select a file to Has to assure the possibility of power supply during the process of upgrade upgrading, or severe damage will be caused. What if upgrade different firmware to different products, and it will also cause severe damage.
  • Page 26: 5、Ping

    Function instruction Function Description Source IP Address Display IP address BF-430 Destination IP Address Input IP address of Remote Host Packet Number Set up the number of PING package, ranged 1 ~4 , the default 4 Ping Size Set up the size of PING package, the utmost setting 1460 bytes.