Fiber optic amplifier
Hide thumbs Also See for BF5 Series:

Advertisement

Quick Links

BF5 Series
Dual digital display type fiber optic amplifiers
Features
● Dual-display for light incident level and setting value(BF5 -D)
● Minute object sensing available with 1/10,000 high resolution
● Enables to detect with high-speed(20,000 times per sec.) moving objects
● 4 response speeds
: Ultra fast mode(50㎲), high speed mode(150㎲),
standard mode(500㎲), long distance mode(4ms)
● Long lasting amplifier regardless of element's life degradation
or temperature change
● Multiple sensitivity setting modes available
: auto tuning, 1 point(maximum sensitivity), 2 point, positioning teaching
● Up to 8 units enable to stack with mutual interference prevention function
using side connectors
● Auto channel setting function for multiple installations
● Slim design(W10×H30×L70mm)
Please read "Caution for your safety" in operation
manual before using.
Specifications
Display type
Dual Display type
NPN open collector output BF5R-D1-N
PNP open collector output BF5R-D1-P
Red LED
Light source
(660nm, modulated)
Power supply
12-24VDC±10%
Current consumption
Max. 50mA
Operation mode
Light ON / Dark ON Selectable
NPN or PNP open collector
Control output
●Load voltage: Max. 24VDC ●Load current: Max. 100mA ●Residual voltage - NPN:Max. 1V, PNP:Max. 3V
Protection circuit
Reverse polarity protection, overcurrent protection, surge absorption
Response time
Ultra Fast : 50㎲, Fast : 150㎲,STD : 500㎲, Long : 4ms Fast : 150㎲, STD : 500㎲, Long : 4ms
●Incident light level: Red, 4digit, 7Segment
Display method
●SV : Green, 4digit, 7Segment
●Main output indicator : Red LED
Incident light level / SV display [4,000/10,000 resolution], Percentage display, High/Low peak value display,
Display function
Normal / Reversed display
Auto tuning, 1 point teaching,
Sensitivity setting
2 point teaching, Positioning teaching
Mutual interference
Max. 8 unit sets (Automatically set regardless of response time)
prevention
Initializing
Initializing to factory mode
Energy saving
Normal / Energy saving 1 / Energy saving 2
Timer
OFF, OFF Delay, ON Delay, One-shot
Insulation resistance
Min. 20MΩ(at 500VDC megger)
Dielectric strength
1,000VAC 50/60Hz for 1 min.
Vibration
1.5mm amplitude at frequency of 10 to 55Hz(for 1 min.) in each X, Y, Z directions for 2 hours
Shock
500m/s
Ambient illumination Incandescent lamp : Max. 3000㏓ Sunlight : Max. 11000㏓
Environ-
Ambient temperature -10 to 50℃, storage: -20 to 70℃
ment
Ambient humidity
35 to 85%RH, storage: 35 to 85%RH
Protection
IP40(IEC standards)
Material
Case : PBT, Cover : PC
Fiber cable
Min. 2kgf
Tightening torque
Connector type wire(ø4, 3-wire, 2m) (AWG22, Core diameter: 0.08mm, Number of cores: 60,
Accessory
Insulator out diameter: ø1.25mm), Side connector
Approval
Unit weight
Approx. 20g
※ The temperature or humidity mentioned in Environment indicates a non freezing or condensation environment.
BF5G-D1-N
BF5B-D1-N
BF5G-D1-P
BF5B-D1-P
Green LED
Blue LED
(530nm, modulated)
(470nm, modulated)
2
(Approx. 50G) in each X, Y, Z directions for 3 times
Fiber Optic Amplifier
Single Display type
BF5R-S1-N
BF5R-S1-P
Red LED
(660nm, modulated)
●Incident light level / SV : Red, 4digit, 7Segment
●Main output indicator : Red LED
Auto tuning
-
-
OFF, 10ms OFF Delay timer, 40ms OFF Delay timer
(A)
Photo
PNP output model
electric
sensor
Line-up
(B)
Fiber
optic
sensor
(C)
Door/Area
sensor
(D)
Proximity
sensor
(E)
Pressure
sensor
(F)
Rotary
encoder
(G)
Connector/
Socket
(H)
Temp.
controller
(I)
SSR/
Power
controller
(J)
Counter
(K)
Timer
(L)
Panel
meter
(M)
Tacho/
Speed/ Pulse
meter
(N)
Display
unit
(O)
Sensor
controller
(P)
Switching
power
supply
(Q)
Stepping
motor&
Driver&Controller
(R)
Graphic/
Logic
panel
(S)
Field
network
device
(T)
Software
(U)
Other
B-9

Advertisement

loading
Need help?

Need help?

Do you have a question about the BF5 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Autonics BF5 Series

  • Page 1 BF5 Series Fiber Optic Amplifier Dual digital display type fiber optic amplifiers Photo PNP output model electric Features sensor Line-up ● Dual-display for light incident level and setting value(BF5 -D) Fiber optic ● Minute object sensing available with 1/10,000 high resolution sensor ●...
  • Page 2: Control Output Diagram

    BF5 Series Control output diagram ● NPN open collector output ● PNP open collector output Fiber optic sensor circuit Connection Fiber optic sensor circuit Connection (Brown)+V (Brown)+V Load Load Over (Black)output Max.100mA current 12-24VDC protection 12-24VDC (Black)output ±10% Over Max.100mA ±10%...
  • Page 3: Parameter Setting

    Fiber Optic Amplifier ① ⑤ Fiber cable connection Photo ● Lift up the protective cover ① and push down the lock electric sensor ② lever to the direction of ② to release the lock setting. ④ ● Insert the cable to the direction of ③ with slightly Fiber ③...
  • Page 4 BF5 Series ● BF5R-S1- RUN mode Press Press Press Press Press Use front slide key for 3 sec. (P) key for 3 sec. (D) key for 3 sec. switches Response time setting Teaching sensitivity Group teaching Manual sensitivity Display function setting...
  • Page 5 Fiber Optic Amplifier 2) One-point teach mode ※ One of teaching modes that sets the maximum sensitivity by teaching one sensitivity setting point when setting the SV Photo electric sensor with no sensing object (Reflective) or when setting the SV with incident light level 0(Through-beam) / Suitable for the applications required little effect of dust or background.
  • Page 6 BF5 Series 4) Positioning teach mode ※ One of teaching modes that sets the sensitivity to 90% of max. incident light level when sensing an object with a hole on the surface (Through-beam) or sensing a moving object having curve (Reflective).
  • Page 7 Fiber Optic Amplifier ● Master / Slave unit display during group teach mode Photo Master Master Master electric sensor unit Slave unit (RUN mode) unit Slave unit unit Slave unit Fiber optic sensor Door/Area sensor Proximity sensor Pressure sensor Press Master ①...
  • Page 8 BF5 Series Sensitive setting Auto 1 point 2 point Position mode SENS AUTO SENS 1PNT SENS 2PNT SENS PSTN Normal Energy Energy saving Energy saving mode saving mode1 mode2 ESAV ESAV 1SAV ESAV 2SAV Light ON/ Light ON Dark ON...
  • Page 9 Fiber Optic Amplifier Energy saving function [ ESAV ] Photo A function to save unit's power consumption by reducing power supply to display parts in case of no setting input electric sensor within 60 sec. ● Selectable from 2 power saving modes Fiber - Normal mode [ NOR ] : Main output indicator(OUT), PV/SV display part ON optic...
  • Page 10 BF5 Series Data Bank mode flow RUN mode ※ Press key for 3 sec. to return to Press for 5 sec. RUN mode in data Bank mode. Data Bank setting mode display DATA BANK Automatically moved after flashing twice (0.5 sec.).
  • Page 11 Fiber Optic Amplifier Master / Slave unit display during data Bank setting Photo ● Copy All electric Master Slave units Master Master Slave units sensor unit (RUN mode) unit Slave units unit (RUN mode) Fiber optic sensor Door/Area sensor Proximity sensor Pressure sensor...
  • Page 12 BF5 Series High peak, Low peak function A function to monitor the high/low peak value of incident light level. The monitored high/low peak value can be initialized. RUN mode Max. Min. incident incident High peak Low peak light level light level...
  • Page 13 Fiber Optic Amplifier Teaching sensitivity setting(Auto tuning teaching) Photo electric ● For BF5R-S1- model, teaching sensitivity setting mode is fixed to auto-tuning. sensor ※ This mode is easy the sensitivity when incident light level of sensing object is not stable or moved fast. ※...
  • Page 14 BF5 Series Light ON / Dark ON switching function A function to set Light ON - control output is ON when incident light level is higher than setting value and Dark ON - control output is ON when incident light level is lower than setting value.
  • Page 15: Error Code

    Fiber Optic Amplifier High peak, low peak function Photo electric A function to monitor the high/low peak value of incident light level. The monitored high/low peak value can be initialized. sensor ※ If there are no key operations within 60 sec., Fiber RUN mode optic...