ZORN INSTRUMENTS ZFG 3000 GPS User Manual

ZORN INSTRUMENTS ZFG 3000 GPS User Manual

Light weight deflectometer

Advertisement

User Manual
Light Weight Deflectometer
ZFG 3000 GPS
ZFG 3000 ECO
German technical test requirements
for soil and rocks in road construction
Benzstraße 1, 39576 Stendal (Germany)
Phone: +49(0) 3931 / 25273 0, Fax: +49(0) 3931 / 25273 10
www.zorn-instruments.de
for the
in accordance with the
TP BF – StB Part B 8.3
info@zorn-instruments.de
Technical changes reserved
Effective: 11/03/2013

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ZFG 3000 GPS and is the answer not in the manual?

Questions and answers

Summary of Contents for ZORN INSTRUMENTS ZFG 3000 GPS

  • Page 1 User Manual for the Light Weight Deflectometer ZFG 3000 GPS ZFG 3000 ECO in accordance with the German technical test requirements for soil and rocks in road construction TP BF – StB Part B 8.3 Benzstraße 1, 39576 Stendal (Germany) Phone: +49(0) 3931 / 25273 0, Fax: +49(0) 3931 / 25273 10 www.zorn-instruments.de...
  • Page 2 ZFG 3000 GPS ZFG 3000 ECO - 2 -...
  • Page 3: Table Of Contents

    Content 1.Intended purpose ........................4 2. Preparation for measurement ..................... 4 3.1 Switching the device on ....................5 3.2 GPS receiver function* ....................5 3.3 Text input function ......................5 3.4 Preloading ......................... 6 3.5 Starting measurement: ...................... 6 3.6 Evaluating and printing the results ................... 7 4.
  • Page 4: Intended Purpose

    1.Intended purpose The dynamic plate load test with the help of the ZFG 3000 Light Weight Deflectometer is a rapid method of determining the dynamic deflection modulus E [MN/m² . This allows conclusions to be made about the load-bearing capacity and compaction of soils. In accordance with German regulations TP BF-Stb Part B8.3, the procedure can be used on mixed-grained and course-grained soils up to a grain size of maximum 63 mm, loose base courses, backfill material and for soil improvement.
  • Page 5: Switching The Device On

    ZFG 3000 11.02.09 11:58:37 Batt: Zorn Instruments The current date/time and battery status are displayed. Please insert the SD card now. to enable data to be saved on the SD card.
  • Page 6: Preloading

     <ON/OFF> Cancels text inserting and starts measuring (no text will be used) When a text was used, it will be saved and is shown as a suggestion at the next measuring. When text ends with a number, the number will be increased at the next measure. When the text input function was cancelled, next text input starts with an empty string.
  • Page 7: Evaluating And Printing The Results

    3.6 Evaluating and printing the results The following results are displayed: 52°35.14’ 11°52.66’ No: 33 11.03.09 13:22 : 0.266 mm s/v: 2.414 : 84.59 MN/m  geographical coordinates  consecutive number (only if SD card is inserted), date and time ...
  • Page 8: Menu

    4. Menu If you press the <Mode> button, you can call up additional device functions. Use the <Ok> button to confirm the menu command selected. Quit the menu by pressing the <On/Off> button. 4.1 Measuring See chapter 2. and 3. 4.2 Read card (display data saved to SD card) ...
  • Page 9: Setting The Clock

    4.5 Setting the clock  Select the Set clock menu command in the menu (see 4.).  You can use the <Mode> button to select the date or time, or to move the cursor to the position you require.  You can change the underlying value by pressing the <+> or <-> buttons. ...
  • Page 10: Printer

    5. Printer The integrated printer is a thermal printer. This requires thermal paper only for printing. To change the thermal paper roll, open the printer compartment by pulling the access depression upwards. Take the empty thermal paper roll out and replace it with a full one. When replacing the thermal paper roll, please ensure that the full thermal paper roll is inserted with the side to be unwound facing to the left and downwards! (Figure 5.1).
  • Page 11: Device View

    7. Device view Mini-printer printout Loading device (10) (10) Loading plate (11) (13) (12) Handle Top limit stop with release device Guide tube Round handle 10 kg fall weight Transport lock Spring element Anti-tip device Centring cone Carrying handle (10) Loading plate (11) Socket for connecting measuring cable to settlement gauge...
  • Page 12: Instructions For Engaging Fall Weight

    8. Instructions for engaging fall weight When engaging the fall weight in the release mechanism, please use both thumbs as shown in the sketch. The fall weight is lifted up as far as possible with both hands until shortly underneath the limit stop so that it can be pressed into the stop using both thumbs as shown in the sketch.
  • Page 13: Technical Data For Settlement Gauge

    11. Technical data for settlement gauge Measuring device dimensions 300x270x170 mm Measuring device weight approx. 4 kg Settlement measuring range 0.3 to 5 mm ± 0.02 mm Sensor acceleration range ±100 g Frequency range 0 to 500 Hz Temperature range 0 to 50 °...
  • Page 14: Calibration Institutes For Drop Weight Tester

    13. Calibration institutes for drop weight tester ZORN INSTRUMENTS HOCHPRÄZISIONS PRÜFTECHNIK Kalibrierstelle Benzstr. 1 D-39576 Stendal Tel.: +49(0) 3931 / 25273-0 Fax: +49(0) 3931 / 25273-10 eMail: info@zorn-instruments.de Please visit the BAST homepage for more calibration institutes: http://www.bast.de/ http://www.bast.de/htdocs/qualitaet/p-stelle/tp-bf.htm - 14 -...
  • Page 15: Correlations

    14. Correlations For information purposes only, no guarantee of information correctness. Quote from German ZTVE- STB 09, Research Institute for Road and Traffic (Edition 2009) 4.5.2 Requirements for deflection modulus The information provided below is based on the 10% minimum quantile. When constructing roads of Construction Classes SV and I to IV (see A &...
  • Page 16 Table A Number of authoritative traffic load construction class more than 3200 1800 to 3200 900 to 1800 300 to 900 60 to 300 10 to 60 up to 10 Table B Road type construction class Highway SV, I, II main street, walking path with a heavy traffic load II, III walking path with traffic load...
  • Page 17 For information purposes only, no guarantee of information correctness Quote from Ril 836, Deutsche Bahn AG (German Rail), (20.12.1999 a) 836.0501 Ril 836 - Designing, constructing and maintaining earthworks Page 10 Soils body Principles Fig. 2 Normal requirements for the construction of rail tracks on soil bodies Route type Formation...
  • Page 18 For information purposes only, no guarantee of information correctness Construction material and soil engineering institute, Wetzlar Backfilling of trenches Verification of compaction with light drop weight tester in accordance with TP BF-StB Part 8.3 Indicators for the allocation of Compaction ratio D Dynamic deflection modulus E Required Based on guide...
  • Page 19: Warranty

    15. Warranty We provide 12 months warranty from date of delivery for all deficiencies that occur on our equipment in the manner that we choose to either repair any deficiency free of charge or replace damaged (faulty) parts with new ones. No warranty claims can be made especially for damage caused by improper use;...
  • Page 20: Ec Conformity Declaration

    16. EC conformity declaration - 20 -...
  • Page 21: Software (Short Manual)

    17. Software (short manual) A detailed manual for using the software is located on installation CD or is available on software by pushing „F1“ resp. in menu in Help/Show Manual. Installation Supported operating systems: Windows 2000, XP, Vista, 7 1. Put the installation CD in the CD drive 2.
  • Page 24 Benzstraße 1, D – 39576 Stendal Telephone +49(0)3931 / 25273 – 0, Fax +49(0)3931 / 25273 – 10 www.zorn-instruments.de info@zorn-instruments.de...

This manual is also suitable for:

Zfg 3000 eco

Table of Contents