VR8245 AND VR8345 ELECTRONIC IGNITION GAS CONTROLS
WARNING
FIRE OR EXPLOSION HAZARD
CAN CAUSE PROPERTY DAMAGE, SEVERE INJURY, OR DEATH
Follow these warnings exactly:
1. Disconnect power supply before wiring to prevent electrical shock or equipment damage.
2. To avoid dangerous accumulation of fuel gas, turn off gas supply at the appliance service valve before
starting installation and perform Gas Leak Test after completion of installation.
3. When working with a system using intermittent pilot ignition, do not bend pilot tubing at gas control or pilot
burner after compression fitting has been tightened because gas leakage at the connection can result.
4. Always install sediment trap in gas supply line to prevent contamination of gas control.
5. Do not force the gas control knob. Use only your hand to turn the gas control knob. Never use any tools. If
the gas control knob will not operate by hand, call a qualified service technician to replace the gas control.
Force or attempted repair can result in fire or explosion.
Valve
(Inlet and Outlet)
VR8245M
1/2 x 1/2
VR8345H,K
3/4 x 3/4
VR8345M
3/4 x 3/4
VR8345Q
3/4 x 3/4
Service Part
VR8245M2530
VR8204M1075, VR8204M1091,
VR8204A1201, VR8204A1219,
VR8204A2001, VR8204A2076,
VR8204A2175, VR8204A2803,
VR8205A2008, VR8205M1106,
VR8205A2024, VR8205M2310,
VR8345H4555
VR8204H1006, VR8304H4503,
VR8305H4013, VR8305H4039,
VR8345M4302
VR8204A1201, VR8204A1219,
VR8204A2001, VR8204A2175,
VR8204A2803, VR8204M1075,
VR8205A2008, VR8205M1106,
VR8205M2310, VR8205M2443,
VR8304M3509, VR8304M4002,
VR8304M4507, VR8305M3506,
VR8305M4066, VR8305M4165,
VR8345Q4563
VR8205Q2381, VR8205Q2555,
VR8205Q2662, VR8205Q2746,
VR8205Q2787, VR8305Q4453,
VR8304Q4511, VR8305Q4138,
VR8305Q4146, VR8305Q4500
CAUTION
Never apply a jumper across or short the valve
coil terminals. This can burn out the heat
anticipator in the thermostat or damage the
electronic intermittent pilot (IP) module.
69-2013—04
Table 3. Fuel Conversion Kits.
Size
Pressure
Regulator Type
Standard
Slow-Opening
Standard
2-Stage
Table 4. Cross Reference.
Resideo
VR8205M2443
VR8205H1003
VR8305M4231
Current Draw (A)
.5
.7
.7
.9
White-Rodgers
36E01-204, 36E01-205,
36E01-206, 36E01-305,
36E22-214, 36E36-304,
36E93-304, 36G22-214,
36J22-214
36E24-214, 36E52-214,
36E93-304, 36E98-304
36C68-423, 36C74-413,
36E01-204, 36E01-205,
36E01-206, 36E01-305,
36E22-214, 36E36-304,
36E93-304, 36G22-214,
36J22-214
36C76-406, 36C76-420,
36C76-463, 36D13-208,
36D13-405, 36E54-214,
36E96-314, 36G54-214
IMPORTANT:
These gas controls are shipped with protective
seals over inlet and outlet tappings. Do not
remove seals until ready to connect piping.
Follow the appliance manufacturer instructions if
available; otherwise, use the following instructions.
2
Conversion Kits
Natural Gas - LP
LP - Natural Gas
393691
394588
393691
394588
393691
394588
396021
396025
Robert-Shaw
720-079 (7200IPER),
720-080 (7200IPER-LP),
722-051 (2000DERHC),
722-079 (2000IPERHC)
720-070 (72000IPER-S7C), 720-
071 (72000IPER-S7C), 720-072
(72000IPER-S7C), 720-073
(72000IPER-LP-S7C)
720-051 (7200DER),
720-079 (7200IPER),
720-080 (7200IPER-LP),
722-051 (2000DERHC),
722-079 (2000IPERHC)
720-082 (7200IPER2-4)