SR Instruments SR Scales SRV712W Operating And Service Manual

Marine scale system

Advertisement

Quick Links

Model SRV712W Marine Scale System
Service Manual
Part No. MAN712W_170816
Page 1 of 14
S
by SR Instruments, Inc.
Marine Scale System
App Enabled Wireless
Operating and Service
Manual
,
SInstruments, Inc.
600 Young Street, Tonawanda, NY 14150
Tel: 716-693-5977
Fax: 716-693-5854 URL:
www.srscales.com
Copyright 2017 SInstruments, Inc.
email:
sri@srinstruments.com

Advertisement

Table of Contents
loading

Summary of Contents for SR Instruments SR Scales SRV712W

  • Page 1 Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 1 of 14 by SR Instruments, Inc. Marine Scale System App Enabled Wireless Operating and Service Manual SInstruments, Inc. 600 Young Street, Tonawanda, NY 14150 Tel: 716-693-5977 Fax: 716-693-5854 URL: www.srscales.com...
  • Page 2: Table Of Contents

    Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 2 of 14 TABLE OF CONTENTS TABLE OF FIGURES ........................2 PACKING CHECKLIST - MODEL SRV712W ................3 ASSEMBLY............................4 REPLACEMENT PARTS AND ACCESSORIES ................5 SYSTEM DESCRIPTION AND INTENDED USE ...............5 MAINTENANCE AND CLEANING ....................5 STORAGE AND TRANSPORTATION ..................6 SPECIFICATIONS...........................7 BUTTON FUNCTIONS ........................8...
  • Page 3: Packing Checklist - Model Srv712W

    Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 3 of 14 PACKING CHECKLIST - Model SRV712W Marine Platform Scale  DESCRIPTION QUANTITY PLATFORM SCALE 1 ea PACK OF SIX (6) “AA” BATTERIES 1 ea CALIBRATION CERTIFICATE 1 ea WARRANTY CARD 1 ea TABLET AND CASE...
  • Page 4: Assembly

    Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 4 of 14 ASSEMBLY STEP 1: Unpack the Marine Scale Platform (1) and check parts against the PACKING CHECKLIST. If there are any missing or damaged parts, call the Service Hotline at: 1-800-654-6360. STEP 2: Place the Platform upside-down on the floor and remove the cover on the Battery Compartment (Figure 1).
  • Page 5: Replacement Parts And Accessories

    Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 5 of 14 REPLACEMENT PARTS and ACCESSORIES Part # Description FK5210039 RUBBER LEVELING FOOT MAN712W MANUAL SYSTEM DESCRIPTION and INTENDED USE SYSTEM DESCRIPTION The SRV712W Marine Platform Scale employs the latest in microprocessor and load cell technology to provide accurate and repeatable weight data.
  • Page 6: Maintenance And Cleaning

    Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 6 of 14 MAINTENANCE and CLEANING The SRV712W readout is built into the scale platform. Exercise caution when WARNING cleaning the display window as it is made of clear acrylic and can be scratched by DO NOT use pressurized water or steam.
  • Page 7: Specifications

    Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 7 of 14 SPECIFICATIONS MAXIMUM WEIGHT 2000 lb / 907 kg (Minimum 10 lb) CAPACITY 22 in x 40 in x 2 ¾ in PLATFORM SIZE 56 cm x 102 cm x 7 cm DISPLAY TYPE 0.2 lb / 0.1 kg DISPLAY RESOLUTION...
  • Page 8: Button Functions

    Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 8 of 14 BUTTON FUNCTIONS The “DISPLAY” button is used to turn the system on and display the subject’s weight. The “DISPLAY” button is also used to zero the system by pressing and holding the “DISPLAY” button for 2-3 seconds.
  • Page 9: Basic System Operation

    Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 9 of 14 BASIC SYSTEM OPERATION Ensure that the scale is free and clear of any obstructions before operating. Press the “DISPLAY” button and hold it for 2-3 seconds. The display will read “0.0” and be ready for weighing.
  • Page 10: Theory Of Operation

    Page 10 of 14 THEORY OF OPERATION SR Instruments patient weighing systems are digital scales. Strain-gauge force cells convert the force of an applied weight into an analog signal. This signal is amplified by an operational amplifier and converted to a digital signal by an analog to digital converter. The digital signal is transferred to a micro-controller where it is filtered, converted to appropriate units and displayed on a liquid crystal display.
  • Page 11: Calibration

    Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 11 of 14 CALIBRATION IMPORTANT CALIBRATION CHECK Qualified service personnel only should perform this procedure. Load cells have no user serviceable components and should not be tampered with for any reason. Re-calibration is generally not required, but should be verified periodically to ensure accuracy.
  • Page 12: Troubleshooting

    Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 12 of 14 CALIBRATION (cont’d) STEP 10: When the display reads “FULL”, place the weight from Step 1 on the platform and press the DISPLAY button. STEP 11: Press the DISPLAY button once more to save. To exit without saving, press S4 to select “QUIT”, then press the DISPLAY button STEP 12: When finished making adjustments, remove all weight from the scale.
  • Page 13: Warranty

    SR Instruments, Inc.’s part, and it neither assumes nor authorizes any other person to assume for SR Instruments, Inc. any other liabilities in connection with the sale of said articles. In no event shall SR Instruments, Inc.
  • Page 14 Model SRV712W Marine Scale System Service Manual Part No. MAN712W_170816 Page 14 of 14 By S Instruments, Inc. Precision & Technology in ® Perfect Balance SInstruments, Inc. 600 Young Street, Tonawanda, NY 14150 Tel: 716-693-5977 Fax: 716-693-5854 URL: www.srscales.com Copyright 2017 SInstruments, Inc. email: sri@srinstruments.com...

Table of Contents