Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment R-134a and R-513A (Cooling Only) with Graphic Control Center for Electromechanical Starter, Solid State Starter, and Variable Speed Drive Installation Guide Form Number: 160.76-N3 (121) Issue Date: 2021-01-15 Supersedes: 160.76-N3 (619)
Page 2
Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
Contents General safety guidelines..........................5 C o n t e n t s Safety symbols............................. 5 Changeability of this document......................6 Associated literature........................... 6 Nomenclature............................7 Shipping and reassembly..........................8 Forms of shipment..........................8 Form 3 – Driveline separate from shells....................8 Form 7 –...
Page 4
Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
General safety guidelines Important: Read before proceeding. This equipment is a relatively complicated apparatus. During rigging, installation, operation, maintenance, or service, individuals may be exposed to certain components or conditions including, but not limited to: heavy objects, refrigerants, materials under pressure, rotating components, and both high and low voltage.
WARNING External wiring, unless specified as an optional connection in the manufacturer’s product line, is not to be connected inside the control cabinet. Devices such as relays, switches, transducers and controls and any external wiring must not be installed inside the micro panel. All wiring must be in accordance with Johnson Controls’...
Manual description Form number Wiring Diagrams - Field Connections - Remote Mounted MVVSD 160.76-PW3 Wiring Diagrams - Field Control Modifications 160.76-PW4 Wiring Diagrams - OptiView Control Center and EMS 160.76-PW5 Wiring Diagrams - OptiView Control Center and SSS, LVVSD 160.76-PW6 Wiring Diagrams - Field Connections - LVVSD 160.76-PW7 Unit Operation and Maintenance...
Shipping and reassembly This instruction explains the procedure to be used for reassembling the Model YK Chiller shipped disassembled (Shipping Form 3, 7, 9, and 10). Note: Chillers must be field reassembled under the supervision of a Johnson Controls representative. For instructions on installing the unit, refer to the Unit Installation Instructions (Form 160.76-N1).
The shipment may include miscellaneous packaging of the control center, oil eductor filter, tubing, water temperature controls, wiring, oil, isolators, solid state starter or variable speed drive (options). The refrigerant charge is shipped in appropriate cylinders. For P and Q compressors, the control panel is removed for shipment.
Inspection – damage – shortage The unit shipment must be checked on arrival to see that all major pieces, boxes, and crates are received. Each unit must be checked on the trailer or rail car when received, before unloading, for any visible signs of damage.
Long-term storage About this task: In order to protect the waterbox of pressure vessels from rusting, the tube side (water side) has been purged and charged with nitrogen to a positive pressure of 5 psig to 7 psig. Do not break the seal or remove closures until ready for setup. Use the following procedure to relieve pressure.
Page 12
Figure 3: Long term storage - tube side Item Description Tag warning Dennison 8E Gauge press 2 dia. 0-30 Tag GlvSt wire speed Bush pipe 3/4 - 14 NPTE X Valve, transducer 1/4 NPTE X Flange cover Gasket Victaulic coupling Sealing cap Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
Shipment Form 2/3/7/9 All openings on the compressor, shells including evaporator and condenser, and oil reservoir are closed and charged with nitrogen (2 psig to 3 psig). WARNING To remove the closures, sealing caps, or sealing plug under pressure is extremely dangerous, and may cause severe injury or death to the operator or people on-site.
Form 3 and Form 7 shipment Assemble vibration isolators to unit. Refer to the Unit Installation Instructions (Form 160.76-N1). Level shells in both directions. Check the longitudinal alignment of the shell by placing a level on the top of the shell, next to the discharge connection. Check the transverse alignment by placing a level on the tops of both end sheets.
Figure 4: Rigging – compressor/motor assembly Note: Rig the driveline into place on the chiller, supporting the compressor with two lifting lugs and the motor with either, one, two, or four legs depending on motor design. Form 9 and Form 10 reassembly Assemble vibration isolators to unit.
Page 16
Note: Relief valves must be plugged or capped. Refer to Operations and Maintenance (Form 160.76-O1). Form 9 - Remove nitrogen and charge unit with refrigerant. Refer to Operations and Maintenance (Form 160.76-O1). 10. All Units: Complete installation and finally level the unit. Refer to Installation Manual (Form 160.76-N1).
Q3-Q8 compressors (with falling film) Figure 6: Form 3 shipment (Q3-Q8 compressors with falling film) Note: * Ring Gaskets NOT used for elastomer-lined flange faces at the isolation valve. Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
Page 18
Figure 7: Form 7 shipment (Q3-Q8 compressors with falling film) Note: * Ring Gaskets NOT used for elastomer-lined flange faces at the isolation valve. Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
P8-P9, H9 compressors (with falling film) Figure 9: Form 3 shipment (P8-P9 and H9 compressors with falling film) Note: * Ring Gaskets NOT used for elastomer-lined flange faces at the isolation valve. Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
Page 21
Figure 10: Form 7 shipment (P8-P9 and H9 compressors with falling film) Note: * Ring Gaskets NOT used for elastomer-lined flange faces at the isolation valve. Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
P8-P9 and H9 compressors Figure 11: System piping (P8-P9 and H9 compressors) Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
K compressors Figure 12: Form 3 shipment (K compressors) Note: * Ring Gaskets NOT used for elastomer-lined flange faces at the isolation valve. Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
Page 24
Figure 13: Form 7 shipment (K compressors) Note: * Ring Gaskets NOT used for elastomer-lined flange faces at the isolation valve. Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
Page 25
Figure 14: System piping (K compressors) Model YK Chillers (Style H) Field Reassembly for Form 3, 7, 9, and 10 Shipment...
Page 31
Note: The weights provided in the following table are intended to be a general reference only. The weights are based on the heaviest anticipated unit combinations as of December 2020. There are numerous factors that can impact these values based on the chiller options selected at the time of the final unit rating.
Page 32
The evaporator marine waterbox weights are to be added to the standard unit weights shown in Table 7. Table 8: Approximate evaporator marine waterbox weights, lb (kg) Unit Shipping weight Operating weight increase, lb (kg) increase, lb (kg) evaporator Compressor code 1-pass 2-pass...
Page 33
The condenser marine waterbox weights are to be added to the standard unit weights shown in Table 7. Table 9: Approximate condenser marine waterbox weights, lb (kg) Unit Shipping weight Operating weight increase, lb (kg) increase, lb (kg) condenser Compressor code 1-pass 2-pass...