ABB Relion 650 Series Communication Protocol Manual

ABB Relion 650 Series Communication Protocol Manual

Hide thumbs Also See for Relion 650 Series:
Table of Contents

Advertisement

Quick Links

®
Relion
650 SERIES
IEC 60870-5-103, 650 series
Version 1.1 IEC
Communication protocol manual

Advertisement

Table of Contents
loading

Summary of Contents for ABB Relion 650 Series

  • Page 1 ® Relion 650 SERIES IEC 60870-5-103, 650 series Version 1.1 IEC Communication protocol manual...
  • Page 3 Document ID: 1MRK 511 243-UEN Issued: November 2019 Revision: A Product version: 1.1 © Copyright 2011 ABB. All rights reserved...
  • Page 4 Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used or disclosed only in accordance with the terms of such license.
  • Page 5 This document has been carefully checked by ABB but deviations cannot be completely ruled out. In case any errors are detected, the reader is kindly requested to notify the manufacturer.
  • Page 6 (Low-voltage directive 2006/95/EC). This conformity is the result of tests conducted by ABB in accordance with the product standards EN 50263 and EN 60255-26 for the EMC directive, and with the product standards EN 60255-1 and EN 60255-27 for the low voltage directive.
  • Page 7: Table Of Contents

    4.1.3.1 Functionality........................26 4.1.3.2 Function block........................26 4.1.3.3 Signals...........................26 4.1.3.4 Settings..........................26 4.1.3.5 Supported information types..................26 4.1.4 Function status earth-fault for IEC 60870-5-103 I103EF..........27 IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 8 Signals........................... 37 4.2.2.4 Settings..........................37 4.2.2.5 Supported information types...................37 4.2.3 Function commands user defined for IEC 60870-5-103 I103USRCMD......38 4.2.3.1 Functionality........................38 4.2.3.2 Function block........................38 4.2.3.3 Signals...........................38 IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 9 5.2.4.2 General commands in control direction................ 48 5.2.4.3 Generic functions in control direction................49 5.2.5 Basic application functions....................49 5.2.6 Miscellaneous........................... 49 Section 6 Glossary......................51 IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 11: Introduction

    Technical manual Technical manual Communication protocol Communication protocol Communication protocol manual manual manual en07000220.vsd IEC07000220 V1 EN-US Figure 1: The intended use of manuals in different lifecycles IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 12: Document Revision History

    Document revision history GUID-52A4699C-F83B-48F8-BF4E-D853043AB731 v1 Document revision/date Product series version History -/February 2011 First release A/November 2019 Maintenance release - Updated safety information and bug corrections IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 13: Related Documents

    Application manual 1MRK 505 266-UEN Technical manual 1MRK 505 267-UEN Commissioning manual 1MRK 505 268-UEN Product Guide 1MRK 505 269-BEN Type test certificate 1MRK 505 269-TEN IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 14: Symbols And Conventions

    LHMI messages are shown in Courier font, for example: To save the changes in non-volatile memory, select Yes and press • Parameter names are shown in italics, for example: IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 15: Functions Included In 650 Series Ieds

    Four-step phase overcurrent protection EFPIOC Instantaneous residual overcurrent protection EF4PTOC 51N/67N Four-step directional residual overcurrent protection SDEPSDE Sensitive directional residual overcurrent and power protection Table continues on next page IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 16 Interlocking for bus-section disconnector ABC_BC Interlocking for bus-coupler bay BH_CONN Interlocking for 1 1/2 breaker diameter BH_LINE_A Interlocking for 1 1/2 breaker diameter Table continues on next page IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 17 INVERTER Configurable logic blocks, Inverter PULSETIMER Configurable logic blocks, PULSETIMER GATE Configurable logic blocks, Controllable gate Configurable logic blocks, exclusive OR Table continues on next page IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 18 IEC61850 generic communication I/O functions SP16GGIO IEC61850 generic communication I/O functions 16 inputs MVGGIO IEC61850 generic communication I/O functions MVEXP Measured value expander block Table continues on next page IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 19 GOOSE function block to receive a double point value GOOSEINTRCV GOOSE function block to receive an integer value GOOSEMVRCV GOOSE function block to receive a measurand value Table continues on next page IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 20 Denial of service, frame rate control for front port DOSLAN1 Denial of service, frame rate control for LAN1 port DOSSCKT Denial of service, socket flow control IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 21: Iec 60870-5-103 Overview

    The standard requires the IEC 60870-5-103 device to provide an interoperability list, which actually is more an interchangeability list. See the vendor specific implementation section in this manual for the interoperability list. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 22 (glass/plastic) and an opto/electrical converter for the PC/ RTU. Table 7: Max distances between IED/nodes Connector Distance glass (ST < 1000 m according to optical budget connector) IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 23: Iec 60870-5-103 Communication Engineering

    MMXU measurement function blocks. See I103MEAS function block for more information. EventRepMode : Defines the mode for how events are reported. The event buffer size is • 1000 events. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 24: Settings

    After setting up the time synchronization source, the user must check and modify the IEC 60870-5-103 time synchronization specific settings, under: IED Configuration/ Communication/Station communication/IEC60870-5-103:1. MasterTimeDomain specifies the format of the time sent by the master. Format can be: • IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 25 EvalTimeAccuracy can be set to Off . According to the standard, the “Bad Time” flag is reported when synchronization has been omitted in the protection for >23 h. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 27: Iec 60870-5-103 Vendor Specific Implementation

    IEC CycMeasRepTime . 60870-5-103 communication using setting GUID-B8A3A04C-430D-4488-9F72-8529FAB0B17D V1 EN-US Figure 5: Settings for CMMXU: 1 IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 28: Function Block

    Maximum current phase L1 MaxIL2 1 - 99999 3000 Maximum current phase L2 MaxIL3 1 - 99999 3000 Maximum current phase L3 Table continues on next page IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 29: Supported Information Types

    Info. no. Message Supported 144, 145, IN, Neutral current 145, 146 UL1-UL2 UN, Neutral voltage 146, 148 P, active power 146, 148 Q, reactive power f, frequency IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 30: Measurands User Defined Signals For Iec 60870-5-103 I103Measusr

    REAL Service value for measurement on input 7 INPUT8 REAL Service value for measurement on input 8 INPUT9 REAL Service value for measurement on input 9 IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 31: Settings

    25 – 27. One for each instance. Information number must be selected for measurands. Info. Message Supported Meas1 Meas2 Meas3 Meas4 Meas5 Meas6 Meas7 Meas8 Meas9 1) * User defined information number IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 32: Function Status Auto-Recloser For Iec 60870-5-103 I103Ar

    Function type is selected with parameter Information number is defined for each output signal. Info. no. Message Supported Autorecloser active Teleprotection active Protection active Table continues on next page IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 33: Function Status Earth-Fault For Iec 60870-5-103 I103Ef

    Earth fault indications in monitor direction, I103EF M11874-199 v3 Number of instances: 1 FunctionType . Function type is selected with parameter Information number is defined for each output signal. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 34: Function Status Fault Protection For Iec 60870-5-103 I103Fltprot

    78_ZONE1 79_ZONE2 80_ZONE3 81_ZONE4 82_ZONE5 84_STGEN 85_BFP 86_MTRL1 87_MTRL2 88_MTRL3 89_MTRN 90_IOC 91_IOC 92_IEF 93_IEF ARINPROG FLTLOC IEC10000291-1-en.vsd IEC10000291 V1 EN-US Figure 10: I103FLTPROT function block IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 35: Signals

    Faultlocator faultlocation valid (LMBRFLO-CALCMADE) 4.1.5.4 Settings PID-2656-SETTINGS v2 Table 18: I103FLTPROT Non group settings (basic) Name Values (Range) Unit Step Default Description FunctionType 1 - 255 Function type (1-255) IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 36: Supported Information Types

    Trip measuring system phase Trip measuring system neutral Over current trip, stage low Over current trip, stage high Earth-fault trip, stage low Earth-fault trip, stage high IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 37: Ied Status For Iec 60870-5-103 I103Ied

    Terminal status indications in monitor direction, I103IED M11874-109 v3 Number of instances: 1 FunctionType . Function type is selected with parameter Information number is defined for each input signals. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 38: Supervison Status For Iec 60870-5-103 I103Superv

    Information number 37, I high-high back-up protection 38_VTFF BOOLEAN Information number 38, fuse failure VT 46_GRWA BOOLEAN Information number 46, group warning 47_GRAL BOOLEAN Information number 47, group alarm IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 39: Settings

    INF17, INF18, INF20 or INF35. After connecting the appropriate InfNo_x values in the settings. signals to the I103USRDEF inputs, the user must also set the IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 40: Function Block

    Binary signal input 4 INPUT5 BOOLEAN Binary signal input 5 INPUT6 BOOLEAN Binary signal input 6 INPUT7 BOOLEAN Binary signal input 7 INPUT8 BOOLEAN Binary signal input 8 IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 41: Settings

    Input signal 02 Input signal 03 Input signal 04 Input signal 05 Input signal 06 Input signal 07 Input signal 08 Commands in control direction M11874-27 v1 IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 42: Function Commands For Iec 60870-5-103 I103Cmd

    FunctionType . Function type is selected with parameter Information number is defined for each output signals. Info. no. Message Supported Auto-recloser on/off Teleprotection on/off Protection on/off IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 43: Ied Commands For Iec 60870-5-103 I103Iedcmd

    Commands in control direction, I103IEDCMD M11874-29 v3 Number of instances: 1 FunctionType . Function type is selected with parameter Information number is defined for each output signals. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 44: Function Commands User Defined For Iec 60870-5-103 I103Usrcmd

    Command output 3 OUTPUT4 BOOLEAN Command output 4 OUTPUT5 BOOLEAN Command output 5 OUTPUT6 BOOLEAN Command output 6 OUTPUT7 BOOLEAN Command output 7 OUTPUT8 BOOLEAN Command output 8 IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 45: Settings

    Message Supported Output signal 01 Output signal 02 Output signal 03 Output signal 04 Output signal 05 Output signal 06 Output signal 07 Output signal 08 IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 46: Function Commands Generic For Iec 60870-5-103 I103Gencmd

    GUID-2F2D2048-7E0D-4254-AE50-DB9700F2F997 v1 Number of instances: 50 FunctionType . Function type for each function block instance is selected with parameter Information number must be selected for command output. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 47: Ied Commands With Position And Select For Iec 60870-5-103 I103Poscmd

    GUID-02A72231-F828-4B19-91A0-8AF3FE681A77 v1 Number of instances: 50 FunctionType . Function type for each function block instance is selected with parameter Information number must be selected for command output. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 48: Disturbance Recorder File Transfer

    The last eight disturbances that are recorded are available for transfer to the master. A successfully transferred disturbance (acknowledged by the master) will not be reported to the master again. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 49 To get INF and FUN for the recorded binary signals there are parameters on the disturbance recorder for each input. The user must set these parameters to whatever he connects to the corresponding input. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 51: Interoperability

    Common address of ASDU GUID-4B6748D2-C329-4937-8C51-60EA28052A2A v1 Table 42: Common address of ASDU Supported One COMMON ADDRESS OF ASDU (identical with station address) More than one COMMON ADDRESS OF ASDU IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 52: Selection Of Standard Information Numbers In Monitor Direction

    Semantics Supported Measurand supervision I Measurand supervision V Phase sequence supervision Trip circuit supervision I>> back-up operation VT fuse failure Teleprotection disturbed Group warning Group alarm IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 53: Earth Fault Indications In Monitor Direction

    Auto-reclosure indications in monitor direction GUID-88F9AFD6-6464-4DE1-AECB-595142BDCDB3 v1 Table 48: Auto-reclosure indications in monitor direction Semantics Supported CB ‘on’ by AR CB ‘on’ by long-time AR AR blocked IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 54: Measurands In Monitor Direction

    Table 52: General commands in control direction Semantics Supported Auto-recloser on/off Teleprotection on/off Protection on/off LED reset 23 to Activate characteristic 1 to Activate characteristic 4 IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 55: Generic Functions In Control Direction

    Max. MVAL = rated value times Current L Current L Current L Voltage L Voltage L Voltage L Active power P Reactive power Q Frequency f Voltage L IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 56 Private range Private range Private range Private range Private range Private range Private range Private range Private range Private range Private range Private range Private range IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 57: Glossary

    Central processor unit Carrier receive Cyclic redundancy check CROB Control relay output block Carrier send Current transformer Capacitive voltage transformer Delayed autoreclosing IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 58 GOOSE Generic object-oriented substation event Global positioning system HDLC protocol High-level data link control, protocol based on the HDLC standard HFBR connector type Plastic fiber connector IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 59 Local detection device Light-emitting diode Miniature circuit breaker Mezzanine carrier module Multifunction vehicle bus. Standardized serial bus originally developed for use in trains. National Control Centre IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 60 Supervision, control and data acquisition System configuration tool according to standard IEC 61850 Service data unit SMA connector Subminiature version A, A threaded connector with constant impedance. IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 61 "Z", which stands for longitude zero. Undervoltage Weak end infeed logic Voltage transformer X.21 A digital signalling interface primarily used for telecom equipment IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 62 Three times zero-sequence current. Often referred to as the residual or the earth-fault current Three times the zero sequence voltage. Often referred to as the residual voltage or the neutral point voltage IEC 60870-5-103, 650 series Communication protocol manual © Copyright 2011 ABB. All rights reserved...
  • Page 64 ABB AB Substation Automation Products SE-721 59 Västerås, Sweden Phone +46 (0) 21 32 50 00 Scan this QR code to visit our website www.abb.com/substationautomation © Copyright 2011 ABB. All rights reserved.

Table of Contents