  • Page 3: Table Of Contents

    CONTENT 1. PRODUCT DESCRIPTION ....................1 Usage in accordance with safety standards ....................1 Brief description ..............................1 Delivery package ............................... 1 Signs and indications of the centrifuge ......................1 1.4.1 General ................................1 1.4.2 Product nameplate ............................2 1.4.3 Declaration of ATEX (94/9/EG) ........................3 1.4.4 Following rules ..............................
  • Page 5: Product Description

    The unit type Z 130 M is a mini centrifuge, which we offer in two voltage variations 230V or 120V. The Z 130 M is suitable for applications with a fixed speed up to 5500 rpm and is capable for 12 x 1.5/2.0ml micro tubes and 4 x PCR strips.
  • Page 6: Product Nameplate

    PRODUCT DESCRIPTION 1.4.2 Product nameplate (sample) Company adress: Hermle Labortechnik GmbH, Siemensstr. 25, D-78564 Wehingen TYPE: Type designation of the product REF: Order number Serial number of the product Date of manufacture Manufacturer MAX. Drehzahl: max. allowed speed of the unit KIN.
  • Page 7: Declaration Of Atex (94/9/Eg)

    PRODUCT DESCRIPTION 1.4.3 Declaration of ATEX (94/9/EG) The HERMLE Z 130 M is not explosion-proof and must therefore not be operated in explosion- endangered areas or locations. During centrifugation, it is prohibited to stay within the safety zone of 30 cm around the centrifuge or deposit hazardous substances within this area. Centrifugation of...
  • Page 8: Installation Of The Centrifuge

    PRODUCT DESCRIPTION 1.5 Installation of the centrifuge 1.5.1 Unpacking the centrifuge Model Z 130 M is supplied in a carton. Remove the strap retainer, open the carton and remove the centrifuge. The instruction manual must always be kept with the centrifuge! 1.5.2 Space requirements...
  • Page 9: Operation

    Therefore we recommend to weighting with a balance. This reduces the wear of drive and the acoustic operating noise. Examples of properly balanced rotors: Figure 1 Represents an empty Represents a loaded position position Z 130 M_V1.15 © Hermle Labortechnik GmbH...
  • Page 10: Examples For Improperly Balanced Rotors

    Represents an empty Represents a loaded position position 2.3 Power switch The power swich is on the left side at the back wall of the housing (see figure 3) Figure 3: Power swich © Hermle Labortechnik GmbH Z 130 M_V1.15...
  • Page 11: Maintenance

    Clean as well the accessories especially the sealings of the aerosol-tight rotors and insert bolts of swing out rotors. Afterwards lubricate the bolts or sealings with the recommended HERMLE vaseline - order no. 41-5215. Lubricants containing molycote and graphite are not allowed.
  • Page 12: Cleaning And Disinfection Of The Rotor

    ATTENTION: Because the temperature may rise during the sterilization, rotors, adapters and bottles must not be closed respectively must be totally unscrewed. Chemical sterilization Bottles, adapters and rotors may be treated with the usual liquid disinfectants. © Hermle Labortechnik GmbH Z 130 M_V1.15...
  • Page 13: Glass Breakage

    „TÜV Nord CERT GmbH, Certification Body Consumer Products, Essen (Germany)“ in accordance with Annex AA of IEC 61010-2-020. The certificates can be downloaded on our webpage www.hermle-labortechnik.de. Aerosol-tight rotors and buckets are marked with the label „aerosol- tight“. ATTENTION: Autoclaving, mechanical stresses and contamination by chemicals or other aggressive solvents can impair the aerosol-tightness of the rotors and buckets.
  • Page 14: Repair

    We reserve the right to accept contaminated centrifuges. Further on all costs occurred for the cleaning and disinfection of the units will go to the debit of the customer’s account. Thank you for your understanding. © Hermle Labortechnik GmbH Z 130 M_V1.15...
  • Page 15: Transport, Storage, Disposal

    RoHS II Compliance HERMLE Labortechnik GmbH, Siemensstraße 25, 78564 Wehingen, hereby declares and certifies that all components manufactured are RoHS II compliant according to the definition and restrictions given by the European Parliament Directive 2011/65/EC on the restriction of use of certain hazardous substances in electrical and electronic equipment.
  • Page 16: Appendix

    APPENDIX Table 1: Technical Data: ....................... I EC conformity declaration ....................II Redemption form / Decontamination certificate ............... III © Hermle Labortechnik GmbH Z 130 M_V1.15...
  • Page 17 Table 1: Technical Data: Manufacturer Benchmark Scientific inc. Type Z 130 M Dimensions Width 14,6 cm Depth 20,3 cm Height 10,8 cm Weight with rotor 1,3 kg max. speed 5500 min max. volume 12 x 1.5/2.0 ml and 4 x PCR-stripes max.
  • Page 18: Ec Conformity Declaration

    EG Konformitätserklärung EC Conformity Declaration Hermle Labortechnik GmbH - Siemensstr. 25 - D-78564 Wehingen – Germany Das bezeichnete Produkt entspricht den einschlägigen grundlegenden Anforderungen der aufgeführten EG-Richtlinien und Normen. Bei einer nicht mit uns abgestimmten Änderung des Produktes oder einer nicht bestimmungsgemäßen Anwendung verliert diese Erklärung ihre Gültigkeit.
  • Page 19: Redemption Form / Decontamination Certificate

    Which one, if yes: ________________________________________________________________ Description of the measures for the decontamination of the listed parts: I confirm the proper decontamination: Company/dept ._____________ place and date: ____________________________________ Signature of the authorized person: ________________________________________ Z 130 M_V1.15 © Hermle Labortechnik GmbH...
  • Page 21: Notes

    6. Notes Z 130 M_V1.15 © Hermle Labortechnik GmbH...
  • Page 22 © Hermle Labortechnik GmbH Z 130 M_V1.15...
  • Page 23 Z 130 M_V1.15 © Hermle Labortechnik GmbH...
  • Page 24 HERMLE Labortechnik GmbH Siemensstrasse 25 78564 Wehingen Tel: 0 74 26-96 22-17 Fax: 0 74 26-96 22-49 Email: vertrieb@hermle-labortechnik.de Internet: http://www.hermle-labortechnik.de Technische Änderungen vorbehalten. ©HERMLE Labortechnik GmbH 2012 © Hermle Labortechnik GmbH Z 130 M_V1.15...