Hydac OLFP-1 Installation And Maintenance Instructions Manual

Hydac OLFP-1 Installation And Maintenance Instructions Manual

Offline filter pressure
Table of Contents

Advertisement

Quick Links

OLFP-1 /-T002
OffLine Filter Pressure
Installation and Maintenance Instructions
English • (translation of original instructions)
Document No. : 4469047 • 10/24/2019
Follow these instructions for proper and safe use.
Keep for future reference.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OLFP-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Hydac OLFP-1

  • Page 1 OLFP-1 /-T002 OffLine Filter Pressure Installation and Maintenance Instructions English • (translation of original instructions) Document No. : 4469047 • 10/24/2019 Follow these instructions for proper and safe use. Keep for future reference.
  • Page 2: Table Of Contents

    Checking the scope of delivery .............. 21 Decoding the type label..................  22 3.4.1 Model code .................. 24 Technical Data .................... 25 3.5.1 Set nominal flow rate .................  25 Dimensions .................... 27 Hydraulic circuit.................... 29 Components.................... 30 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 3 Differential pressure indicator, visual – VM x BM.x ...... 53 8.2.3 Differential pressure gauge, electric (VM x C.x) ........  55 8.2.4 Differential pressure gauge, electric (VM x D.x /-L-xx) ......  57 Finding a Customer Service team.............. 59 Glossary ........................ 62 Index ........................ 63 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 4: General

    Dipl.Kfm. Wolfgang Haering Tab. 1: Impressum 1.2 Documentation Representative The contact data of the person authorized with the documenta- tion is: Mr. Günter Harge c/o HYDAC International GmbH, Industriegebiet, 66280 Sulzbach / Saar Germany Phone: +49 6897 509 1511 Fax: +49 6897 509 1394 E-mail: guenter.harge@hydac.com...
  • Page 5: Purpose Of This Manual

    Observe the additional product-related in- structions and requirements. Specialist person- Read, observe and follow this manual and the associated documents, in particular, the safety and warning instructions. Tab. 3: Target group MoWa OLFP-1-T002 4469047 en-us lq 5 / 64...
  • Page 6: Illustrations In The Manual

    Supplementary instructions regarding the validity of the manual (optional) Please note that you can directly access information through the directories. However, this does not release you from the obligation to read this manual fully before commissioning. 6 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 7: Representation Of Requirements

    1. Remove the transport securing device. 2. First fill the product. 3. Switch the product on. Procedural instructions with a random sequence Procedural instructions that have a random sequence are listed as bullet points (-). MoWa OLFP-1-T002 4469047 en-us lq 7 / 64...
  • Page 8: Representation Of Intermediate Results/Results

    An example for a procedural instruction with intermediate re- sult and final result: 1. Switch the product on. ð The display lights up. 2. Press the button. O The product is now ready for use. 8 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 9: Representation Of Warning/General Safety Information

    Warning / general safety information, which are placed ahead of each activity, are represented as follows: CAUTION Type and source of danger Consequence of the danger Hazard symbol Measures to avert danger ► MoWa OLFP-1-T002 4469047 en-us lq 9 / 64...
  • Page 10: Signal Words And Their Meaning In The General Safety Information

    NOTICE NOTICE – The signal word indicates a hazardous situation with a high level of risk, which, if not avoided, will result in damage to property. 10 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 11: Hazard Symbols / Pictograms

    Follow the instructions. Other symbols used These signs are listed for the general safety instructions in these operating instructions, for example, which indicate a par- ticular danger to persons, property or the environment. MoWa OLFP-1-T002 4469047 en-us lq 11 / 64...
  • Page 12: Supplementary Symbols

    1.7 Supplementary symbols You will find the following symbols in the manual as additional details: Tip for handling the product 12 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 13: Exclusion Of Liability/Warranty

    Delivery. They are made available to you at the conclusion of the contract at the latest. You will also find these under www.hydac.com -> General Terms and Conditions (T&C). This manual was prepared to the best of our knowledge. Nev- ertheless and despite the greatest care, it cannot be excluded that mistakes could have crept in.
  • Page 14: Validity Of This Manual

    The diagrams and visualizations in this manual are meant for general illustration purposes. Therefore, representations and functional options can deviate from the delivered product. We reserve the right to changes to the contents of this manual without prior notice. 14 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 15: Safety Information

    Use the filter housing/filter unit only with the permissible operating media. WARNING The hydraulic system is under pressure during operation Danger of bodily injury u The hydraulic system must be depressurized before per- forming any work on the hydraulic system. MoWa OLFP-1-T002 4469047 en-us lq 15 / 64...
  • Page 16 Make sure that the pressure port is always open during operation. NOTICE Incorrect storage The clogging indicator will be damaged/destroyed. u Make sure that the clogging indicator is free, without any contact to the floor or to other components. 16 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 17 NOTICE Impermissible operating medium The filter housing/filter unit will be damaged/destroyed. u Use the filter housing/filter unit only together with mineral oils and mineral oil based-raffinates respectively. MoWa OLFP-1-T002 4469047 en-us lq 17 / 64...
  • Page 18: Filter Housing Overview

    – Longer oil change intervals – Minimum space requirement due to compact design – Very easy maintenance – High dirt holding capacity of the elements – Environmentally friendly element disposal as it can be incenerated 18 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 19: Proper/Designated Use

    The manufacturer assumes no responsibility for determining the interfaces for installation in a system or the installation, use or functionality of the product in this system. MoWa OLFP-1-T002 4469047 en-us lq 19 / 64...
  • Page 20: Improper Use Or Use Deviating From Intended Use

    – Operation when the safety devices are defective. – Modifications to the power unit made by the user or pur- chaser. – Inadequate monitoring of parts that are subject to wear and tear. – Improperly performed repair work. 20 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 21: Checking The Scope Of Delivery

    Check the filter housing for any damage when it is deliv- ered. Immediately report any damage in transit to the forwarding agent or the HYDAC department in charge. Commissioning may not be performed if the filter housing is damaged. Qty.
  • Page 22: Decoding The Type Label

    Part no. - Part number S/N - Serial number/year of manufacture Power - Power consumption Voltage/Grid - Voltage/power supply Frequency - Frequency Current - Current consumption Pressure max - Operating pressure, maximum Weight - Empty weight 22 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 23 HYDAC FILTER SYSTEMS GMBH Filter housing overview | 3 Flow rate - Flow rate Temp. oil - Permitted fluid temperature range Temp. amb. - Permitted ambient temperature range Volume - Volume (content) MoWa OLFP-1-T002 4469047 en-us lq 23 / 64...
  • Page 24: Model Code

    C = Differential pressure gauge, electrical (VM2C.x) D3 = Differential pressure gauge, optical/electrical (VM2D.x) Supplementary details Fig. 4: OLFP model code D38 = Differential pressure gauge, electrical VL x GW.0 /-V-113 Z = without 24 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 25: Technical Data

    3.5.1 Set nominal flow rate The nominal flow rate is limited by an orifice. The type of orifice used can be seen on the model code, for example OLFP x/2 = 2 l/min = orifice A. MoWa OLFP-1-T002 4469047 en-us lq 25 / 64...
  • Page 26: Fig. 5 Nominal Flow Rate Diagram

    OLFP x/2 2 l/min OLFP x/3 3 l/min OLFP x/6 6 l/min OLFP x/z variable Tab. 6: Orifice/Nominal flow rate The diagram shows the flow rate of a clean, unused filter ele- ment. 26 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 27: Dimensions

    Filter housing overview | 3 3.6 Dimensions In this chapter, you will find the drawings with the dimensions of the different designs of the filter units/filter housings. Fig. 6: Dimensions of OLFP-1/x-… /T-002 IN Inlet OUT Outlet DPI Clogging indicator DRAIN Drain...
  • Page 28 3 | Filter housing overview HYDAC FILTER SYSTEMS GMBH All dimensions in mm. 28 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 29: Hydraulic Circuit

    Filter housing overview | 3 3.7 Hydraulic circuit In this chapter, you will find the hydraulic diagram of the differ- ent designs of the filter housings. Fig. 7: Hydraulic diagram OLFP-1 /-T002 IN Inlet OUT Outlet DPI Clogging indicator DRAIN Drain...
  • Page 30: Components

    3 | Filter housing overview HYDAC FILTER SYSTEMS GMBH 3.8 Components The filter housing has the following components: Fig. 8: Components of the OLFP-1 /-T002 1 Filter connection piece 2 Filter housing 3 Filter cover 4 Air bleed plug [Air bleed]...
  • Page 31: Transportation/Storage

    Fully empty the filter unit/filter housing before transporting it or putting it into storage. Remove the used filter element and clean the inside of the filter housing. Fig. 9: Lifting OLFP with strap MoWa OLFP-1-T002 4469047 en-us lq 31 / 64...
  • Page 32: Fig. 10 Storing The Olfp

    Store the filter housing / filter unit in a standing position in clean and dry rooms without condensing humidity. The permit- ted storage conditions are available in chapter "Technical Data". Fig. 10: Storing the OLFP 32 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 33: Mounting/Installing

    Fasten the OLFP using the four Ø 9 mm bores on the filter connector according to the following diagram. Fig. 11: Fastening/mounting the filter housing MoWa OLFP-1-T002 4469047 en-us lq 33 / 64...
  • Page 34: Fig. 12 Observing The Removal Space

    Make sure there is adequate removal space (X) for changing the filter element. In order to make the filter element change easier, install shut-off devices in the immediate vicinity of the filter housing (B). 34 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 35: Avoiding Siphoning

    After the filter unit is switched off, the height difference/primary pressure can cause flow to occur both in the feed direction and against the feed direction and the fluid can leak uncontrollably. MoWa OLFP-1-T002 4469047 en-us lq 35 / 64...
  • Page 36: Observing/Calculating Pressure Loss

    – Avoid constrictions in the connected hoses. This reduces the power and increases the risk of cavitation. – Note that the nominal size of the connected hose/piping must correspond to the cross-section of the connection thread. 36 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 37 – Make sure that the connection hoses/piping (suction side/ pressure side) do not cause any tension or vibrations to be carried over to the filter unit. Use hoses or expansion joints if necessary. MoWa OLFP-1-T002 4469047 en-us lq 37 / 64...
  • Page 38: Measure Or Display Dynamic Pressure / Differential Pressure

    = Back-pressure ∆p4 = Differential pressure p4 = Back-pressure In the example, the back pressure at the first measurement point shows the total of the subsequent pressures in the hy- draulic system. 38 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 39: Connecting The Electric Clogging Indicator (Optional)

    Install the filter element before starting up the unit. 1. Switch the pump on and chect the installation for any leaks. 2. Vent the filter housing at the "VENT" connection. O The commissioning is complete. MoWa OLFP-1-T002 4469047 en-us lq 39 / 64...
  • Page 40: Checking The Installation

    Make sure that the pressure port is always open during operation. 5.7 Checking the installation Check all the electric/hydraulic connections, screwed connec- tions and components for firm seating. After commissioning, check all the functions and for leaks. 40 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 41: Operation

    When the clogging indicator has responded, change the filter element/filter cartridge. Information on changing the filter ele- ment can be found in chapter Performing maintenance [} 42]. See also 2 Performing maintenance [} 42] MoWa OLFP-1-T002 4469047 en-us lq 41 / 64...
  • Page 42: Performing Maintenance

    1x Allen wrench  = 6 mm To change the filter, proceed as follows: 1. Switch off the pump in the hydraulic system or shut the shut-off valve at the inlet IN and outlet OUT. 42 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 43 4. Loosen the filter lid counterclockwise. Unscrew the filter lid fully by hand. CAUTION! Due to spring force, the filter lid springs up slightly after it has reached the last thread. MoWa OLFP-1-T002 4469047 en-us lq 43 / 64...
  • Page 44 7. Check the O-ring for damage, and replace it if neces- sary. Coat the threads in the filter lid with aluminum paste. The part no. can be found in the spare parts list. 44 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 45 (II) During the filling process, take note of the vent bore. (III) Shut the shut off device at the inlet IN as soon as fluid escapes. MoWa OLFP-1-T002 4469047 en-us lq 45 / 64...
  • Page 46 12. Open the shut off device (II) at the outlet OUT slowly. After commissioning, check the filter unit for leaks. O The filter element change is now complete. The filter housing is ready for operation. 46 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 47: Appendix

    Use only original spare parts and accessories. When ordering spare parts and accessories make sure to always indicate the exact model code and the serial number. The following spare parts are available for the product: Fig. 16: Spare parts 1/2 MoWa OLFP-1-T002 4469047 en-us lq 47 / 64...
  • Page 48: Fig. 17: Spare Parts 2/2

    8 | Appendix HYDAC FILTER SYSTEMS GMBH Fig. 17: Spare parts 2/2 48 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 49 BM.1 /-V 12.0 1 Adapter SAE-2 12.1 4 Cylinder head screw 12.2 4 Flat washer 12.3 1 O-ring 616987 12.3 1 O-ring 604192 13.0 1 Orifice 14.0 1 Screw plug DIN 910 MoWa OLFP-1-T002 4469047 en-us lq 49 / 64...
  • Page 50: Tab. 7 Spare Parts

    Screw connection 19.0 1 Ball valve 551094 20.0 1 Filter element, 3 µm N1TM003 3284980 Aluminum paste, 1 kg 3090398 Tab. 7: Spare Parts *) On demand -) Not available as a spare part 50 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 51: Clogging Indicators - Technical Data

    Fig. 18: Differential pressure indicator - visual VM x B.x Type of indication Visual display with a green-red field, automatic reset Weight 55 g Response pressure and indi- VM 2 B.x = 2 bar -10% cation range respectively VM 3 B.x = 3 bar -10% VM 5 B.x = 5 bar -10% MoWa OLFP-1-T002 4469047 en-us lq 51 / 64...
  • Page 52: Tab. 8: Differential Pressure Indicator -Visual Vm X B.x

    HYDAC FILTER SYSTEMS GMBH Permissible operating over- ≤ 210 bar pressure Permitted temperature range -30 … +100°C Connector threads G ½ Installation space required According to HN 28-22 Maximum tightening torque 33 Nm Tab. 8: Differential pressure indicator -visual VM x B.x 52 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 53: Differential Pressure Indicator, Visual - Vm X Bm.x

    Fig. 19: Differential pressure gauge, visual VM x BM.x Type of indication Visual display by green-red field, manual reset Weight 55 g Response pressure and indi- VM 2 BM.x = 2 bar -10% cation range respectively VM 3 BM.x = 3 bar -10% VM 5 BM.x = 5 bar -10% MoWa OLFP-1-T002 4469047 en-us lq 53 / 64...
  • Page 54: Tab. 9: Differential Pressure Indicator, Visual Vm X Bm.x

    8 | Appendix HYDAC FILTER SYSTEMS GMBH Permissible operating over- ≤ 210 bar pressure Permitted temperature range -30 … +100°C Connector threads G ½ Installation space required According to HN 28-22 Tab. 9: Differential pressure indicator, visual VM x BM.x 54 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 55: Differential Pressure Gauge, Electric (Vm X C.x)

    The electric clogging indicator reacts to the increasing pres- sure difference at the increasing contamination level of the fil- ter element. Fig. 20: Differential pressure indicator, electrical VM x C.x Type of indication Electrical switch Weight 120 g MoWa OLFP-1-T002 4469047 en-us lq 55 / 64...
  • Page 56: Tab. 10: Differential Pressure Indicator, Electrical Vm X C.x

    Electrical connection Male connection M20 Female connector to DIN EN 175301-803 Protection class in accordance IP 65 (only if the connector is with DIN 40050 wired and fitted correctly) Tab. 10: Differential pressure indicator, electrical VM x C.x 56 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 57: Differential Pressure Gauge, Electric (Vm X D.x /-L-Xx)

    The electric clogging indicator reacts to the increasing pres- sure difference at the increasing contamination level of the fil- ter element. Fig. 21: Differential pressure indicator, electrical VM x D.x /-Lxx Type of indication Visual indicator and electrical switch Weight 150 g MoWa OLFP-1-T002 4469047 en-us lq 57 / 64...
  • Page 58: Tab. 11 Differential Pressure Indicator, Electrical Vm X D.x / -Lxx

    0.03 to 5 A @ 230 V AC Electrical connection Male connection M20 Female connector to DIN EN 175301-803 Protection class in accordance IP 65 (only if the connector is with DIN 40050 wired and fitted correctly) Tab. 11: Differential pressure indicator, electrical VM x D.x / -Lxx 58 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 59: Finding A Customer Service Team

    HYDAC SYSTEMS & SERVICES GMBH Friedrichsthaler Str. 15, Werk 13 66450 Neunkirchen - Heinitz Germany Phone: +49 6897 509 01 Fax: +49 6897 509 324 E-mail: service@hydac.com Homepage: www.hydac.com Tab. 12: Customer service in Germany MoWa OLFP-1-T002 4469047 en-us lq 59 / 64...
  • Page 60 Nominal flow rate diagram................ Fig. 6 Dimensions of OLFP-1/x-… /T-002 ............Fig. 7 Hydraulic diagram OLFP-1 /-T002 ............Fig. 8 Components of the OLFP-1 /-T002 ............Fig. 9 Lifting OLFP with strap ................Fig. 10 Storing the OLFP..................Fig. 11 Fastening/mounting the filter housing ............
  • Page 61 Differential pressure indicator -visual VM x B.x ........Tab. 9 Differential pressure indicator, visual VM x BM.x ........Tab. 10 Differential pressure indicator, electrical VM x C.x ........Tab. 11 Differential pressure indicator, electrical VM x D.x / -Lxx ......Tab. 12 Customer service in Germany ..............MoWa OLFP-1-T002 4469047 en-us lq 61 / 64...
  • Page 62: Glossary

    They are a combination of pleated and SpunSpray depth filter elements. The filter layers used are produced using melt-blown technology (syn- thetic fibers). 62 / 64 MoWa OLFP-1-T002 4469047 en-us lq...
  • Page 63: Index

    VM x B.x  52 Support  59 VM x BM.x  54 differential pressure/dynamic pressure  38 Terms and Conditions  13 dynamic pressure/differential pressure Terms of Delivery  13  38 warranty  13 exclusion of liability  13 Hotline  59 MoWa OLFP-1-T002 4469047 en-us lq 63 / 64...

This manual is also suitable for:

Olfp-1-t002

Table of Contents