Page 2
PLEASE DO NOT RETURN THIS PUMP TO THE RETAILER. If you experience any issues with your Dr. Brown’s Pump, please contact our dedicated Customer Service team by: https://www.drbrownsbaby.com/contact/ 1-800-778-9001 READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. PLEASE SAVE THESE INSTRUCTIONS.
1.Important Safeguards READ ALL INSTRUCTIONS BEFORE USING THIS PRODUCT. PLEASE SAVE THESE INSTRUCTIONS. WARNING: Read this ENTIRE “Instructions For Use” manual to become familiar with the features of the product before operating. Failure to operate the product correctly can result in damage to the product, personal property and cause serious injury.
Page 5
• The breast pump should never be left unattended when plugged into a power source. • Never operate an electrical device if it has a damaged cord, plug orbattery pack, if it is not working properly, if it has been dropped or damaged, or dropped into water.
Page 6
1.Important Safeguards (cont.) WARNING: To avoid health risk and reduce the risk of injury: • Repairs must be performed only by an authorized service agency. Do not • Do not store wet or damp parts as mold may develop. repair yourself! Do not modify this device or accessories. •...
2. Product Description Dr. Brown’s™ breast pump includes (2) collection kits: Membrane Membrane Co Breast Flange Tubi nnector Valve Dr. Brown’s Feeding Parts (x 2) ottle Includes (2) complete 4oz (120 Included Accessories: ml) Dr. Brown’s® Options +™ bottles: Narrow Neck Travel Cap “Narrow”...
Page 8
Your Dr. Brown’s™ Double breast pump motor: Storage Area Elapse Bottle Holder Bottle Holder Time Wide Neck Adaptor Mode Indicator Bottle Holder Power On-Run-Off LetDown Expression Mode Display Light On-Off Vacuum Level Display Cycle Rate Display Vacuum Level Pump-Release Up / Down Cycles Per Minute Up / Down Hose Po...
Page 9
3.Getting Started 3-1. Disassemble The Breast flange/Milk Collection Kit comes pre-assembled. All milk contact components must be disassembled, washed and sanitized. ¼ TURN PULL PULL UNTHREAD Questions? Please visit www.drbrownsbaby.com/contact/ or call 1-800-778-9001...
Page 10
3-2. Wash Separate and wash all milk contact components by hand in warm water with mild detergent and rinse with clear water or place in the Only use drinking quality water for cleaning! top rack of dishwasher. Non-Milk Contact Milk Contact Components (Wash If Required) See section 3-6 for special tubing care instructions.
3. Getting Started continued Do not submerge the pump motor in water! Wipe clean with a damp cloth only. 3-3. Dry If not for immediate use or sanitizing: Allow all parts to air dry on a clean surface or towel. NEVER store wet or damp parts.
Page 12
3-5. Dry after Sanitizing. Allow all parts to air dry on a clean surface or towel. NEVER store wet or damp parts. Store clean, dry pump kit in a clean bag or container until next use. Sanitize parts before each use. 3-6.
4. Product Assembly 4-1. Collection Kit Assembly PUSH ¼ TURN PUSH DROP IN THREAD INSTALL VALVE HERE Questions? Please visit www.drbrownsbaby.com/contact/ or call 1-800-778-9001...
Page 14
4-2. Tubing Connection Male End Connects to Collector Female End Connects to Pump If pumping in single mode, use port plug to block the unused port.
5. Power Adaptor 5-1. Power Connection The power adapter supplied with this unit is polarized (one prong is larger than the other). Always connect to a polarized outlet. 6 VDC 115 V TO 6 VDC POWER ADAPTOR 5-2. Power Adapter Care To prevent damage to your power adapter cord, always grasp the body of the adapter as shown below.
6. Operating the Pump 6-1. Pumping Modes Two Modes are available: 1) Letdown Mode- Used to stimulates the release of milk from the breast. This mode helps prompt the reflex that happens when nerves in your breasts are stimulated (usually by your baby's sucking). 2) Expression Mode- Used after the breast is stimulated to release milk.
Page 17
6. Operating the Pump 6-2. Using Letdown Mode (continued) 1) Select the [Power Button] to turn the unit on. The pump will automatically display Letdown Mode at the last used vacuum level used (this pump has a memory feature that recalls the last used settings for both modes).
Page 18
6-3. Using Expression Mode (continued) Select the [Mode Selector Button]. When in Expression mode, the Letdown mode symbol will disappear. The pump will automatically start in the last used cycle and vacuum levels (this pump has a memory feature that recalls the last used settings for both modes).
Page 19
6. Operating the Pump 6-5. Placement of the Collection Assembly Center the breast Flange on your breast sothat the nipple is aligned with the tunnel portion. Make sure your breast completely fills the Flange to ensure a seal and that a vacuum can form. While you may feel some discomfort when first breast pumping, it should not cause pain.
Page 20
6-6. Storing a Collection Assembly Often when double pumping, one side is finished before the other. The completed side may be removed from the breast and placed in the convenient half-moon bottle holders or large storage space in the back of the pump housing. The expandable netting will secure the bottle and assembly without risk of spillage.
7. Storing Breast Milk 7-1. Milk Storage Containers You may store expressed milk directly in the bottle after pumping. Simply unthread from the Collector assembly and attach a clean sterilized storage cap (included). We recommend you store milk in our disposable Dr. Brown’s™ Breastmilk Storage Bags (sold separately) for easy identification and space savings.
Page 22
7-2. Milk Storage Guidelines Guidelines Are for Home Use and Not for Hospital Use. Use the following guidelines for the storage of breastmilk. By following recommended storage and preparation techniques, nursing mothers and caretakers of breastfed infants and children can maintain the safety and quality of expressed breast milk for the health of the baby.
Page 23
8. Preparing & Feeding 8-1. Fresh Breast Milk If the milk is freshly expressed or thawed to feeding temperature, simply feed in a clean sanitized bottle. Discard any remaining milk after 2 hours. 8-2. Refrigerated Breast Milk Warm the milk to desired feeding temperature in a clean sanitized bottle.
Page 24
Need a faster way to safely thaw and warm breast milk? The Dr. Brown’s® MilkSpa™ Breast Milk and Bottle Warmer quickly and gently thaws and warms milk in storage bags or bottles. The patented pulsating water action warms without overheating, which can reduce nutrients.
9. Technical Data 9-1. Power Supply AC Wall Plug Adaptor: 100-240V 50/60 Hz 0.3A Max Output: 6 VDC 2.0A Regulatory Compliance: XXXXXX 9-2. EMF Compatibility Wireless Statement: Wireless communications equipment such as wireless home network devices, mobile phones, cordless telephones and their base stations, walkie-talkies can affect the electric breast pump and should be kept at least a distance 1.0 m away from the equipment.
Page 26
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
9. Troubleshooting Possible Issue Checks Solution Causes Check if the Confirm if plugged into power cord is not working wall outlet and in Adaptor connected or it is Power power port in back of the damaged. pump. Check connection to Collector and Tubing Confirm connections.
10. Important Symbols This symbol indicates do not dispose the device together with unsorted municipal waste (in accordance with local regulations). This symbol indicates compliance with international requirements for protection from electric shock. (Type BF applied parts.) This symbol indicates that the power adaptor is a class II device. This symbol indicates that the power adaptor is for indoor use only.
11. Warranty Warranty This breast pump device is warrantied against defective material or workmanship for a period of one year from the date of purchase. Any defective part will be repaired or replaced at no charge if it has not been tampered with and appliance has been used according to these printed instructions.
Need help?
Do you have a question about the BF100 and is the answer not in the manual?