Page 1
SPECIFICATIONS MANUAL NLV-4001 NLV-4001 CCD Barcode Scanner This manual provides specifications for The NLV-4001 fixed position 1D imager scanner.
Page 2
OR USING THE PRODUCT. Serial Number A serial number appears on all Opticon products. This official registration number is directly related to the device purchased. Do not remove the serial number from your Opticon device. Removing the serial number voids the warranty.
Page 3
SPECIFICATIONS MANUAL NLV-4001 Revision History Product Name : NLV-4001 Edition Date Page Section Description of Changes 2016/3/28 Initial release Update the cover image. Revise Regulatory Compliance, LED safety: IEC 62471-1:2006 (Exempt_Group) IEC 62471 Exempt Risk Group, delete note. Revise Regulatory Compliance: EMI/RFI ...
Page 7
This manual provides specifications for the NLV-4001 Barcode scanner. Overview ・The NLV-4001 is a Barcode scanner with a built-in 1D CCD linear imager. ・The scanner can read bar codes from LCD screens. ・A single red LED aiming line toward a target bar code can help the users find the appropriate scanning position.
Page 8
SPECIFICATIONS MANUAL NLV-4001 Basic Specification Item Specification Note 32 bit CISC Core: 96 MHz SRAM 96 KB Flash ROM 512 KB + 32 KB RS-232C 300bps to 115200bps Default: 9600bps Full Speed 12 Mbps Scan method CCD linear image sensor...
Page 9
SPECIFICATIONS MANUAL NLV-4001 Item Specification Note Operating -5 to 50°C Temperature Storage -20 to 60°C Operating 10 to 90% (No condensing, no frost) Humidity Storage 5 to 95% (No condensing, no frost) JAN-13 (resolution Ambient light immunity 10,000 lx or less 0.26 mm) DOF 59 mm...
Page 10
SPECIFICATIONS MANUAL NLV-4001 Detailed View Figure 1: Detail View of NLV-4001 Name Description Light paths of the LED illumination. Ensure that the lens is not exposed Scan window to dust and dirt before scanning. Status LED Green LED light indicates good read.
Page 11
SPECIFICATIONS MANUAL NLV-4001 Electrical specifications <Configuration> The scanner consists of - CCD Module section; where the 1500-pixel CCD sensor, illumination LED, light receiving lens and illumination lens are mounted, and - Main PCB; where the CPU (decode/communication controller which processes bar code signals are combined), the power supply section that converts the main power to 3.3 V, the communication...
Page 12
For the USB-COM interface type, our USB-COM driver must be installed on your host device. Please use the latest version driver. After NLV-4001 and host device are connected, while communication setting is on process, the status LED flashes. During this time, scanning operation is unable.
Page 13
SPECIFICATIONS MANUAL NLV-4001 6.1.3 Interface Circuit Modular Modular connector connector USB A connector USB A connector Pin No. Pin No. Signal name Signal name Interface cable Interface cable - Data - Data + Data + Data Shell Shell Shielded wire...
Page 14
SPECIFICATIONS MANUAL NLV-4001 6.2.2 Signal Level and Pin Assignment Signal names are based on the signals transmitted from the scanner to the host. Signal Name Pin No. Note Black Gray Blue Green White Shield GND Black Brown Signal Level Voltage(V)
Page 16
SPECIFICATIONS MANUAL NLV-4001 Technical Specifications The conditions for technical specifications are as follows unless otherwise specified in each section. <Conditions> Temperature and humidity Room temperature, room humidity Illumination LED Ambient light 300 to 500 lx Bar codes Refer to Section 8.1.
Page 17
SPECIFICATIONS MANUAL NLV-4001 8.2 Scan Area and Depth of Field The scan area is within the arc centered on the scan origin as shown in each resolution, which is measured from the front edge of the scanner. 0" 2" 4"...
Page 18
SPECIFICATIONS MANUAL NLV-4001 8.4 Minimum Resolution Resolution 0.076mm or more <Conditions> Bar code : 20digit Code 39, resolution 0.076 mm, PCS 0.9 specified in Section 8.1. Distance : 50 mm from the front edge of the scanner : α = 0°, β = + 15°, γ = 0° (refer to Section 8.5.) Angle : R = ∞...
Page 19
SPECIFICATIONS MANUAL NLV-4001 8.6 Curvature : R ≥ 15 mm 0.26 mm 8-digit JAN : R ≥ 20 mm 0.26 mm 13-digit JAN <Conditions> Bar code : JAN, resolution 0.26 mm, specified in Section 8.1. Distance : 114 mm from the front edge of the scanner : α...
Page 20
SPECIFICATIONS MANUAL NLV-4001 Environmental Specifications 9.1 Operating Temperature and Humidity Temperature: -5 to 50° C Humidity: 10 to 90% RH (Non Condensing) 9.2 Storage Temperature and Humidity Temperature: -20 to 60° C Humidity: 5 to 95% RH (Non Condensing) 9.3 Static Electricity ±...
Page 21
SPECIFICATIONS MANUAL NLV-4001 9.5 Vibration Strength (without packing) There shall be no sign of malfunction after the following vibration test. Vibration test: Increase the frequency of the vibration from 10Hz to 100Hz at an accelerated velocity of 19.6m/s (2.0 G) for 30 minutes (60 minutes per cycle) in the non-operating state. Repeat this in each X, Y and Z direction.
Page 22
SPECIFICATIONS MANUAL NLV-4001 9.10 Cable Strength There shall be no sign of malfunction after the following cable strength test. Cable Strength Test: Affix the scanner to an immovable object and pull it using a force of 24.5 N (2.5 kgf static loading) for 1 second. Repeat this 20 times continuously.
Page 23
SPECIFICATIONS MANUAL NLV-4001 Universal Command This scanner can be configured through the RS-232 interface or the USB interface (provided it is configured as USB-COM). Unlike Universal menu labels, Universal commands are executed immediately but are not stored in non volatile memory. Only when a special command (The <Z2>...
Page 24
SPECIFICATIONS MANUAL NLV-4001 Product Label The product label is affixed to the scanner as shown below. Product label Figure 14: Product Label Label material: Laminate: PET film, White, thickness 50 µm. RoHS compliant X X X X X X Figure 15: Product Label...
Page 25
SPECIFICATIONS MANUAL NLV-4001 Packaging Specifications 12.1 Individual Packaging Specification PROTECTION BAG E Protection Bag B85009-09 NLV-4001 納品時のカラータイ使用 MSH-110 BOX B85006-15* 【原産国表示】~country of origin~ 中国生産(produced in China)=MADE IN CHINA Put a cable onto the protection bag. Put a cable onto the PROTECTION BAG E.
Page 26
SPECIFICATIONS MANUAL NLV-4001 12.2 Collective Packaging Specification BOX:B85006-15* Rows The order of serial - No. ① 1~10 Carton Box ② 11~20 Carton Box: 5B0009 ③ 21~30 Packaged 100 sets Packaged 100 sets ④ 31~40 into the Carton-Box ⑤ 41~50 into the Carton-Box.
Page 27
SPECIFICATIONS MANUAL NLV-4001 Regulatory Compliance 13.1 LED Safety IEC 62471:2006 Exempt Risk Group 13.2 EMC EN 55024:2010 EN 55032:2012 +AC:2013 Class B FCC Part 15 Subpart B Class B This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: ( 1 ) this device may not cause harmful Interference, and ( 2 ) this device must accept any interference received, including interference that may cause undesired operation.
Page 28
SPECIFICATIONS MANUAL NLV-4001 Safety Precautions Handle this product carefully. Do not deliberately subject it to any of the following. 14.1 Installation Environment Do not use the product in environments containing flammable or explosive gases. Do not use the product in environments containing corrosive or combustible gases.
Page 29
SPECIFICATIONS MANUAL NLV-4001 Factory Setting 15.1 Default Menu Bar Codes The scanner is reset to each interface’s factory default by reading the following menu bar codes. Function Menu Label Menu Code _ZZ_ _BAP_ Default setting* _ZZ_ (*) The default settings are as follows.
Page 31
SPECIFICATIONS MANUAL NLV-4001 15.3 Default Setting (Part 2: Read Options, Illumination LED, Trigger, Buzzer) Item Default Setting of number of characters Off all codes Read mode Single read Multiple read reset time 500 msec Add-on wait mode 500 msec Multiple label read (code only)
Page 32
SPECIFICATIONS MANUAL NLV-4001 15.4 Default Setting (Part 3: Communication Settings) 15.4.1 USB Interface Item Default Send ‘Enter key’ after scanned data Enable Send ‘Tab key’ after scanned data Disable Send ‘Right arrow key’ after scanned data Disable Other CDC/ACM compliant (USB-VCP) *To use in USB-COM, OPTOELECTRONICS USB-COM driver needs to be downloaded.
Page 33
SPECIFICATIONS MANUAL NLV-4001 15.5 Other Settings: Illumination LED On-off switching of illumination LED may affect the improvement of reading performance. The following modes are configurable. ・ Enable illumination LED : The scanner reads a bar code with the illumination LED turned ON.
Page 34
SPECIFICATIONS MANUAL NLV-4001 15.6 Other Settings: Auto Trigger The scanner has an optional auto trigger mode in which it starts to read a bar code automatically when it detects one. When auto trigger mode is enabled, the scanner tries to detect bars at regular intervals and when it detects 9 or more bars, it enters read mode in which it tries to decode a bar code.
Page 35
SPECIFICATIONS MANUAL NLV-4001 Enable auto trigger all time. Function Menu label Menu code _ZZ_ _+I_ Auto trigger always _ZZ_ Only trigger manually Function Menu label Menu code _ZZ_ _+F_ Manual trigger (Disable auto trigger) _ZZ_...
Page 36
SPECIFICATIONS MANUAL NLV-4001 Physical Features 16.1 Dimensions Approx. 33.0 mm × 41.1 mm x 24.0 mm (DWH) 16.2 Weight Approx. 50 g (RS-232C type include Cable) 55 g (USB type include cable) 16.3 Mechanical Drawing (41.1) (18.4) (35.1) (2.8) Machine Screw Hole Machine Screw Hole M2x0.4 Depth3...
Need help?
Do you have a question about the NLV-4001 and is the answer not in the manual?
Questions and answers