Dometic WH-6GA Installation And Operation Manual

Dometic WH-6GA Installation And Operation Manual

L.p. gas water heater
Hide thumbs Also See for WH-6GA:
Table of Contents

Advertisement

Available languages

Available languages

WH - 6GA, WH - 6GEA, WH - 9GEA
L.P. Gas Water Heater
EN
Installation and Operation Manual . . . . . . . .2
Chauffe-eau à gaz P.L.
FR
Manuel d'installation et d'utilisation . . . . 24

WARNING
This product can expose you to lead which is
known to the state of California to cause cancer and
birth defects or other reproductive harm. For more
information go to www.P65warnings.ca.gov.

DANGER: BURN HAZARD, FIRE, EXPLOSION,
AND/OR CARBON MONOXIDE HAZARD.
Keep the water heater area clear of combustible
cleaning materials, gasoline, and other flammable
vapors and liquids. Failure to obey this warning
could result in damage, a burn hazard, possible
explosion, carbon monoxide buildup, serious
injury, or death.
HEATING
WATER HEATERS
REVISION A Form No. 93765 05/19 | ©2019 Dometic Corporation
WARNING: If the information in this
manual is not followed exactly, a fire or
explosion may result, causing property
damage, personal injury, or death.
– Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Evacuate all persons from the vehicle.
• Shut off gas supply at the gas
container or source.
• Do not touch any electrical switch, or
use any phone or radio in the vehicle.
• Do not start the vehicle's engine or
electric generator.
• Contact the nearest gas supplier
or qualified service technician for
repairs.
• If you cannot reach a gas supplier or
qualified service technician, contact
the nearest fire department.
• Do not turn on the gas supply until the
gas leak(s) has been repaired.
– Installation and service must be
performed by a qualified installer, service
agency or the gas supplier.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WH-6GA and is the answer not in the manual?

Questions and answers

steve mallen
February 28, 2025

I have 3 wires coming from the inside switch to the water heater outside brown, blue, red and of course green to the old heater plug to control unit. I dont see how you tie these wires to the new heater unit and controls.

Summary of Contents for Dometic WH-6GA

  • Page 1 – Installation and service must be performed by a qualified installer, service agency or the gas supplier. REVISION A Form No. 93765 05/19 | ©2019 Dometic Corporation...
  • Page 2: Table Of Contents

    Service Center & Dealer Locations Special Requirements for XT Models ..19 Visit: www.dometic.com Servicing the Mixing Valve ....19 Read these instructions carefully. These instructions Servicing the Pressure-Temperature Relief MUST stay with this product.
  • Page 3: Supplemental Directives

    • Read and follow all safety information and water heater. Dometic Corporation reserves the right to instructions. modify appearances and specifications without notice. • Read and understand these instructions before Dometic Corporation accepts no liability for damage in installing, operating, or servicing this product.
  • Page 4: Component Locations

    Hot Water Outlet Relief Valve (T and P) unit. If you have questions, contact your dealer, a Cold Water Inlet DSI Control Board Dometic Service Center, or the Dometic Service Department. Gas Valve Electric Junction Box/ Element Access Cover (this cover must be sealed)
  • Page 5: Unit Specifications

    10 in. W.C. This is a common installation for water heaters. There are other approved methods such as Baggage Compartment and Flush Mount installations. Consult your Field Auditor, Account Manager, or the Dometic Service Department if you have questions.
  • Page 6: Preparing The Installation Location

    Installation L .P . Gas Water Heater 4.1 Preparing the Installation 2. Erect the side walls and cut the opening. Refer to the table below for cutout specifications for basic water Location heater models. Model Cutout Length Depth WH - 6GA 12.75 in.
  • Page 7: Installing The Water Hose

    L .P . Gas Water Heater Installation 4.2 Installing The Water Hose 6. Apply sealant to the threads of the 1/2 in. (1.27 cm) (NPT) cold water outlet hose. 7. Connect the 1/2 in. (1.27 cm) (NPT) cold water inlet hose to the proper fitting on the water heater using a suitable plastic fitting.
  • Page 8: Installing The Control Switch

    4.4 Installing The Control Switch Dometic recommends that the water heater unit be connected directly to a 12 VDC battery or to the filtered side of an AC/DC converter. Avoid connections to the unfiltered side of an AC/DC converter whenever possible.
  • Page 9: Wiring The 115 Vac Power Supply

    L .P . Gas Water Heater Installation 1. Plan the location of the control switch(es). Refer to “Wiring Diagrams” on page 22 for a comprehensive wiring schematic. 2. Cut the appropriate size hole to fit the control switch leaving enough room to mount the switch using the Please consider the following before wiring the control proper hardware.
  • Page 10 Installation L .P . Gas Water Heater 1. Install the blue wire for the Lock-Out Lamp from the 2. Install the black +12 VDC wire to the spade water heater onto the spade connector on the back connector on the back of the control switch assigned of the control switch.
  • Page 11: Installing The Unit

    L .P . Gas Water Heater Installation The face of the control switch indicates which • Protect building material from flue gas exhaust. switch is intended for each control option. The • Install the water heater on an exterior wall with access lightning bolt indicates use with the electronic to a door opening to the outdoors.
  • Page 12: Installing The Access Door

    Installation L .P . Gas Water Heater 4.7 Installing The Access Door 2. Push the unit against the caulking in the cutout. 11 Securing the Corner Brackets and Flange 12 Attaching the Access Door with the Hinge Pin Corner Bracket #8-3/4 in.
  • Page 13: Performing Leak Testing

    L .P . Gas Water Heater Operation 4.8 Performing Leak Testing WARNING: FIRE AND/OR EXPLOSION HAZARD. Failure to obey this warning could WARNING: FIRE AND/OR EXPLOSION result in death or serious injury: HAZARD. • Do not store or use gasoline or other flammable Do not use matches, candles, or other sources vapors and liquids in the vicinity of this or any other of control when checking for gas leaks.
  • Page 14: Operating The Electronic Control

    2. Place the control switch in the OFF position and wait 30 seconds. 3. Turn the control switch to the ON position. If the lockout condition persists: 1. Read the Maintenance and Care Instructions and the Electronic Control Maintenance in this manual. 2. Contact a Dometic Service Center.
  • Page 15: Shutting Down The Water Heater

    L .P . Gas Water Heater Maintenance And Care 6 Maintenance And Care 5.3 Shutting Down the Water Heater WARNING: FIRE OR EXPLOSION HAZARD. Failure to obey these warnings could result in death or serious injury: • When performing any maintenance or care, shut off the gas supply at the L.P.
  • Page 16: Performing Preventative Maintenance

    Maintenance And Care L .P . Gas Water Heater 6.2 Performing Preventative Once the short is corrected, replace the 2 amp fuse with a mini ATO style fuse. Maintenance Do not install a fuse larger than 3 amps. Spiders, mud wasps, and other insects can build nests in the burner tube.
  • Page 17: Maintaining The Water Heater Tank

    L .P . Gas Water Heater Maintenance And Care 6.2.1 Electronic Ignition Module Cleaning 18 Module Board Module Board 6.3 Maintaining the Water Heater Tank CAUTION: SCALDING HAZARD. 17 Inspecting the Electrode Turn off the water heater and allow time for the 1.
  • Page 18 2. Apply air pressure through the TP Valve. remaining in the tank. For a permanent solution, Dometic recommends one of If sporadic water flow is encountered, open the the following procedures: Pressure-Temperature Relief Valve to allow air into the tank.
  • Page 19: Special Requirements For Xt Models

    L .P . Gas Water Heater Maintenance And Care 6.3.3 Flushing the Tank 7. Cycle the water heater with the vinegar/water solution, letting It run under normal operation four to Use this procedure for general flushing of the water five times. heater tank.
  • Page 20: Servicing The Pressure-Temperature Relief

    HAZARD. Failure to obey the following closed water system of an RV, may cause the Pressure- warnings could result in death or serious Temperature Relief Valve to drip. The Dometic water injury heater tank is designed with an internal air gap at the •...
  • Page 21: Devices

    L .P . Gas Water Heater Disposal 6.7 Using After-Market Water Heating Element Devices WARNING: EXPLOSION AND OR BURN INJURY. Failure to obey the following warnings could result in death or serious injury: • Do not use after-market heating elements. After market heating elements can lack critical safety controls.
  • Page 22: Wiring Diagrams

    Wiring Diagrams L .P . Gas Water Heater 8 Wiring Diagrams Dotted lines are wired by the customer. Blank 4 Remote Switches Brown 3 Electric White 2 +12 VDC Orange 1 Green 6 Green 5 -12 VDC Red 4 Eco Switch Blue 3 Gas Valve Remote...
  • Page 23: Warranty Information

    Refer to the sections below for information about warranty and warranty support in the US, Canada, and all other regions. 9.1 United States and Canada LIMITED WARRANTY AVAILABLE AT WWW.DOMETIC. COM/WARRANTY. IF YOU HAVE QUESTIONS, OR TO OBTAIN A COPY OF THE LIMITED WARRANTY FREE OF CHARGE,...
  • Page 24 CHAUFFAGE CHAUFFE-EAU AVERTISSEMENT : Suivre à la lettre les consignes énoncées dans ce manuel, sinon il y aurait risque de départ de feu ou d’explosion causant des dégâts matériels, des blessures personnelles, voire la mort. – Ne pas stocker ni utiliser d’essence ou d’autres vapeurs ou liquides inflammables à...
  • Page 25: Reconnaître Les Consignes De Sécurité

    Liste des centres de service et des revendeurs Entretien du réservoir du chauffe-eau ..41 Consultez : www.dometic.com Exigences particulières pour les modèles XT ......43 Lire attentivement ces instructions.
  • Page 26: Sécurité

    • L’installation doit se conformer à tous les codes pour garantir l’installation, l’utilisation et l’entretien locaux ou nationaux applicables, y compris la toute corrects du chauffe-eau. Dometic Corporation se réserve dernière édition des normes suivantes : le droit de modifier l’apparence et les caractéristiques techniques de l’appareil sans préavis.
  • Page 27: Informations Générales

    Les composants et leur emplacement peuvent varier selon le modèle. Les mesures peuvent varier de ±0,38 po (10 mm). 3.1 Outils et matériel La Dometic Corporation recommande l’utilisation des outils suivants lors de la maintenance des chauffe-eau. Outils et matériel recommandés Mastic ou ruban de butyle Vis à...
  • Page 28: Identification Du Modèle

    être inférieure à 10 po C.E. Quel que soit votre numéro de révision, ces instructions s’appliquent en général à votre unité. Pour toute question, contactez votre revendeur, un centre de réparation Dometic ou le service après-vente Dometic.
  • Page 29: Installation

    Il s’agit d’une méthode d’installation courante pour les chauffe-eau. Il existe d’autres méthodes homologuées telles que les installations encastrées ou dans la soute à bagages. Consulter votre inspecteur sur le terrain, votre responsable de compte ou le service après-vente Dometic pour toute question supplémentaire.
  • Page 30: Installation Du Tuyau D'eau

    Installation Chauffe-eau à gaz P .L . 4.2 Installation du tuyau d’eau Longueur de Modèle Profondeur la découpe WH - 6GA 12,75 po 19,5 po WH - 6GEA (31,75 cm) (49,53 cm) 12,75 po 24 po WH - 9GEA (31,75 cm) (60,96 cm) Le tableau suivant contient les distances minimales exigées par rapport à...
  • Page 31: Installation De La Ligne De Gaz

    4.3 Installation de la ligne de gaz 4.4 Installation de l’interrupteur (Arrière) Dometic recommande de brancher le chauffe-eau directement sur une batterie de 12 V c.c. ou en aval du filtre du convertisseur électrique c.a./c.c. Éviter les branchements en amont du convertisseur c.a./c.c., si possible.
  • Page 32: Câblage De L'alimentation

    Installation Chauffe-eau à gaz P .L . 1. Choisir l’emplacement du ou des interrupteurs. 2. Découper un trou de taille suffisant pour l’interrupteur de façon à laisser assez de place pour fixer l’interrupteur avec le matériel adapté. 4.4.2 Terminer l’installation de l’interrupteur Avant de terminer l’installation de l’interrupteur, voir «...
  • Page 33 Chauffe-eau à gaz P .L . Installation 4.5.1 Configuration AVIS: Lorsque Romex est utilisé avec une mise ® à la terre nue, faire attention de placer le fil de terre d’un interrupteur simple de manière à ce qu’il n’entre pas en contact avec les bornes de l’élément de chauffe. Cela peut endommager le fil de terre.
  • Page 34 Installation Chauffe-eau à gaz P .L . 4.5.2 Configuration d’un interrupteur 6. Brancher le fil blanc du chauffe-eau sur le connecteur à cosse plate à l’arrière de l’interrupteur assigné simple à fonction combinée à la commande électronique. 7. Brancher le fil de terre vert du connecteur à cosse plate à...
  • Page 35: Installation De L'appareil

    Chauffe-eau à gaz P .L . Installation 3. Brancher le fil bleu du voyant de verrouillage • Ne pas utiliser de chargeur de batterie pour du chauffe-eau sur le connecteur à cosse plate alimenter le chauffe-eau à quelque moment que ce dans le port vide de l’interrupteur. soit, même lors de tests.
  • Page 36: Installation De La Trappe D'accès

    Installation Chauffe-eau à gaz P .L . 4.7 Installation de la trappe d’accès 11 Fixer les équerres de fixation et la bride Équerre de fixation Vis #8 de 3/4 po 12 Attacher la trappe d’accès avec un axe de charnière (22,22 cm) Axe de charnière Trappe d’accès Bride...
  • Page 37: Mode D'emploi

    Chauffe-eau à gaz P .L . Mode d’emploi Déconnecter le chauffe-eau du réseau de gaz avant • Les appareils à gaz ne doivent jamais fonctionner tout test de pression supérieure ou égale à 0,5 psi lorsque le véhicule se déplace. Des mouvements (34 mbar).
  • Page 38: Résoudre Une Défaillance Dans Le Fonctionnement Du Chauffe-Eau

    Pour remédier à ce problème, vérifier que le contact entre le thermostat et 2. Contacter un centre de réparation Dometic. le réservoir est adéquat. Réinitialiser la commande en mettant l’interrupteur électrique en position OFF (Arrêt), puis en position ON (Marche).
  • Page 39: Éteindre Le Chauffe-Eau

    Chauffe-eau à gaz P .L . Entretien et nettoyage 5.3 Éteindre le chauffe-eau Lors d’une maintenance sur les commandes, étiqueter tous les fils avant de les débrancher. Vérifier le bon fonctionnement après une maintenance. Faire tester la pression du gaz régulièrement. La pression doit être réglée sur 11 po (27,94 cm) de colonne d’eau lorsque 3 appareils fonctionnent.
  • Page 40: Effectuer L'entretien Préventif

    Entretien et nettoyage Chauffe-eau à gaz P .L . Le système de coupure thermique est un dispositif installé sur la ligne d’alimentation. 15 Système de coupure thermique Ce dispositif, une fois déclenché, coupe l’arrivée du 16 Tube du brûleur courant électrique et le fonctionnement du chauffe- eau.
  • Page 41: Entretien Du Réservoir Du Chauffe-Eau

    Chauffe-eau à gaz P .L . Entretien et nettoyage 3. S’assurer du bon alignement du brûleur principal Avant le rangement à long terme ou avant l’arrivée et des soupapes. du gel, évacuer et rincer le réservoir. 4. Vérifier que la porcelaine de l’électrode ne comporte 1.
  • Page 42 3. Continuer à rincer le réservoir jusqu’à ce que l’eau de T et P. sortant des conduits de vidange soit claire. Pour une solution permanente, Dometic vous conseille 4. Remettre le bouchon de vidange. l’une des procédures suivantes : 1. Installer une soupape de sécurité de température et pression dans la conduite d’arrivée d’eau froide...
  • Page 43: Exigences Particulières Pour

    Chauffe-eau à gaz P .L . Entretien et nettoyage 6.3.4 Rincer pour éliminer 6.4 Exigences particulières pour les les mauvaises odeurs modèles XT Une odeur d’œuf pourri (sulfure d’hydrogène) pourra Si le débit d’eau au robinet d’eau chaude est faible ou se dégager du fait de l’action électrogalvanique du que l’eau ne semble pas aussi chaude à...
  • Page 44: Réparation De La Soupape De Sécurité De Température Et Pression

    VR. Le réservoir du chauffe- sécurité de température et pression. eau Dometic comporte une poche d’air interne en haut du réservoir qui permet de réduire les risques La soupape de sécurité de température et pression d’égouttement.
  • Page 45: Utilisation D'éléments De Chauffage De L'eau Qui Ne Sont Pas D'origine

    Chauffe-eau à gaz P .L . Élimination 6.7 Utilisation d’éléments de chauffage de l’eau qui ne sont pas d’origine AVERTISSEMENT : RISQUE D’EXPLOSION OU DE BRÛLURE. Le non-respect de ces avertissements pourrait entraîner de graves blessures, voire la mort : • Ne pas utiliser des éléments de chauffage provenant du marché...
  • Page 46: Diagrammes De Câblage

    Diagrammes de câblage Chauffe-eau à gaz P .L . 8 Diagrammes de câblage Les lignes en pointillé sont câblées par le client. Vide 4 Interrupteur à distance Marron 3 Électrique Blanc 2 +12 V c.c. Orange 1 Vert 6 Vert 5 -12 V c.c. Rouge 4 Interrupteur ECO Bleu 3...
  • Page 47: Informations De Garantie

    Voir les sections ci-dessus pour des renseignements sur la garantie et l’assistance sous garantie aux États-Unis, au Canada et dans toutes les autres régions. 9.1 États-Unis et Canada GARANTIE LIMITÉE DISPONIBLE À WWW.DOMETIC. COM/WARRANTY. POUR TOUTE QUESTION OU POUR OBTENIR UNE COPIE GRATUITE DE LA GARANTIE LIMITÉE, CONTACTER :...
  • Page 48 YOUR LOCAL YOUR LOCAL YOUR LOCAL DEALER SUPPORT SALES OFFICE dometic.com/dealer dometic.com/contact dometic.com/sales-offices A complete list of Dometic companies, which comprise the Dometic Group, can be found in the public filings of: DOMETIC GROUP AB Hemvärnsgatan 15 SE-17154 Solna Sweden...

This manual is also suitable for:

Wh-6geaWh-9gea

Table of Contents

Save PDF