Download Print this page

Raven Hawkeye Operation Manual page 104

Nozzle control
Hide thumbs Also See for Hawkeye:

Advertisement

A
D
PPENDIX
TABLE 3. Nozzle Control Valve Seal Replacement Kit Components
I
t
TeeJet (P/N 117-1005-050)
e
Hypro/Arag (P/N 117-1005-051)
m
Wilger (P/N 117-1005-052)
TeeJet
1.
a
Fly Nut
2.
Plunger
Assembly
3.
O-Ring
4.
Valve
107-1005-001
ab
Body
5.
Flat Seal
Outlet
Seal
219-1005-001M
6.
Stackable
219-1005-115M
O-Ring
(56 Pack)
Turret
219-1005-116M
a. Appearance may vary.
b. Valve body replacements not included in seal replacement kits - sold separately.
FIGURE 1. Seal Replacement Kits and Valve Body Assembly
5
6
NOZZLE CONTROL VALVE MAINTENANCE PROCEDURE
Hawkeye nozzle control valves are designed to provide up to 500 hours maintenance free operation with proper
equipment maintenance as recommended by the equipment or chemical manufacturer. However, the seals may
become worn or swollen due to chemical compounds, chemical formulations, or high operating pressures. This
may cause accelerated wear to the sealing surfaces. The following nozzle control valve maintenance procedures
94
Seal Replacement Kits
Hypro
107-1005-002
Flat Seal
219-1005-001M
219-1005-115M
1
2
3
4
Wilger
321-0000-457
321-0000-459
107-1005-003
O-Ring
219-1005-002M
219-1005-116M
Fly Nut Wrench
Valve Body Removal
Tool
(P/N 321-0000-457)
Hawkeye Nozzle Control Operation Manual
Hawkeye Service Tools
Hawkeye Valve Body
Removal Tool
(1/4" Drive)
Hawkeye Fly Nut
Wrench

Advertisement

loading
Need help?

Need help?

Do you have a question about the Hawkeye and is the answer not in the manual?

Questions and answers