Page 1
Installation - Parts ® E-Flo Electric Pumps 3A6586D for Sealants and Adhesives For use with single-component sealant and adhesive materials. For professional use only. Not approved for use in explosive atmospheres or hazardous locations. See page 3 for model information, including maximum working pressure and approvals. Important Safety Instructions Read all warnings and instructions in this manual and in all related manuals before...
Models Models NOTE: Each Check-Mate pump size is available in CS, Check your pump package’s identification (ID) label located on the side of the electric driver for the 8-digit CM, SS, and SM pump materials. Dura-Flo pump mate- part number of your pump package. Use the following rial combinations depend on the pump size.
Models System Pressure Due to factors such as the dispensing system design, the material being pumped, and the flow rate, the dynamic pressure will not reach the rated working (stall) pressure of the system. Pump Working (Stall) Pressure Max Dynamic (Run) Pressure Lower Size 6,000 41.4...
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
Page 6
Warnings WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. Paint or solvent flowing through the equipment can cause static sparking. To help prevent fire and explosion: • Use equipment only in well-ventilated area. •...
Component Identification Advanced Display Module (ADM) Front and Rear Views . 2: ADM Component Identification Key: BA Pump Enable BG Lock/Setup Enables the pump. Toggles between Active and System Toggle between run and setup screens. BH Directional Keypad Off. BB Pump Status Indicator Light Navigate within a screen or to a new screen.
29 megaohms, replace the hose immediately. Dispense valve: ground through connection to a prop- Three pump mounting options are available from Graco: erly grounded fluid hose and pump. a pump stand, a wall mount, and a floor mount adapter.
Installation Connect Power NOTE: Inside the junction box, power wires to the driver are connected to terminals 3L2 and 5L3 on the discon- nect block. Refer to Figure 5 for the terminal locations. All electrical wiring must be done by a qualified elec- Incoming Power to trician and comply with all local codes and regula-...
Installation Connect the Standalone NOTE: Do not attach the ground wire to the grounding lug locknut located by the wiring cord grip on the outside Transformer of the electric driver. The lug locknut should only be used for other grounding purposes if needed. 6.
Installation Install Vented Oil Cap Before 7. Connect wiring (not included) to X1 and X2 and a ground wire to the grounding bar. This wiring is for Using Equipment. connection to the pump. The driver gear-box is shipped from the factory pre-filled Connections to Pump with oil.
Installation Connecting Multiple Pumps Up to six E-Flo SP pumps can be connected together 1. Connect a CAN cable from port 1 on the first pump (shown as Pump 1 in Figure 11) to the splitter. and operated from one Advanced Display Module (ADM).
NOTE: The pump is tested with lightweight oil, which is left in to protect the pump parts. If the fluid you are using Before starting, fill the wet cup (H) 1/3 full with Graco may be contaminated by the oil, flush it out with a com- Throat Seal Liquid (TSL) or a compatible solvent.
Page 15
Setup 4. Enter the Edit screen for that pump by pressing the soft key next to the icon. 5. Press the soft key next to the Pressure Mode icon. 6. Enter 100 psi (0.69 MPa, 6.9 bar) as the pressure. 7.
If you are pumping a water-based fluid, flush with water first. Then flush with a rust NOTE: Refer to the E-Flo SP Software Instructions inhibitor, such as mineral spirits. Relieve pressure, manual for additional information about using the soft- but leave the rust inhibitor in the pump to protect ware features of the ADM.
Parts Parts Electric Pumps with Check-Mate Lowers NOTE: These parts apply to all Check-Mate electric pump configurations. EC100CS3 Shown EC100xxx to EC250xxx Pumps Included with 480 VAC models only. 1f 2 Torque to 50-60 ft-lbs (68-81 N•m). Torque to 124-155 ft-lbs (168-210 N•m). Apply blue pipe sealant.
Page 19
BUSHING, hex hd, 3/4 npt X 1 npt, ss 131526 FITTING, nipple, 1 in. npt, cs 131524 FITTING, nipple, 1 in. npt, ss 1p 17Y515 LABEL, e-flo sp 1r C38321* TIE, cable, 3.62 LG 24P823 MODULE, control, bracket 24E451 MODULE, gca, adm 121001* CABLE, can, female / female 1.0 m...
Page 20
Parts Ref Part Description Quantity Electric Driver Warning Labels 16W360 LABEL, safety, warning, multiple 17J476 LABEL, safety, warning, multiple 195792 LABEL, safety, warning, electric shock 195793 LABEL, safety, warning, electric shock Pump Lower Warning Labels 184090 PLATE, warning 184462 PLATE, warning, sst 48 184151...
Parts Electric Pumps with Dura-Flo Lowers NOTE: These parts apply to all Dura-Flo electric pump configurations. ED115CS3 Shown Included with 480 VAC models only. Torque to 50-60 ft-lbs (68-81 N•m). Torque to 90-100 ft-lbs (122-136 N•m). Apply blue pipe sealant. Apply tan lubricant.
Page 23
FITTING, nipple, 1 in. npt, cs 131524 FITTING, nipple, 1 in. npt, ss 1n 158586 FITTING, bushing, 3/4 x 1 npt 1p 17Y515 LABEL, e-flo sp 1r C38321* TIE, cable, 3.62 LG 24P823 MODULE, control, bracket 24E451 MODULE, gca, adm 121001* CABLE, can, female / female 1.0 m...
Page 24
Parts Ref Part Description Quantity 123970 SWITCH, disconnect, 40 a 123971 KNOB, disconnect, operator 130692 COVER, juction box, apd motor 113768 SCREW, socket, fl hd 16T764 LABEL, warning 25E268‡ KIT, transformer, stand alone Electric Driver Warning Labels 16W360 LABEL, safety, warning, multiple 17J476...
Parts Check Valves Check Valve Block with Pressure Relief, 25N738 NOTE: For model EC100xxx only. Apply a light coating of anti-seize lubricant as needed. 218 2 Torque to 30 +/- 2 ft-lbs (41 +/- 2 N•m). Apply blue sealant to threads as needed. Apply grease.
Page 26
Parts Check Valve Block, 1-1/2 Inch, 25N739 NOTE: For models EC500xxx and ED430xxx 314 1 Apply a light coating of anti-seize lubricant as needed. Torque to 100 ft-lbs (136 N•m). . 17: 1-1/2 Inch Check Valve Part Description BLOCK, check valve, 1-12 in. npt sst HOUSING, ball cage 1-1/2 in.
Page 27
Parts Check Valve Block, 1 Inch, 25N780 NOTE: For models EC200xxx, EC250xxx, ED115xxx, ED145xxx, ED180xxx, ED220xxx, ED290xxx 414 1 Apply a light coating of anti-seize lubricant as needed. Torque to 100 ft-lbs (136 N•m). . 18: 1 Inch Check Valve Part Description BLOCK, check valve, 1 in.
Kits and Accessories Communication Gateway Module (CGM) Kits 4. Drill the mounting holes using the mounting hole dimensions shown in Figure 21. #10-32 UNF (M5 x 0.8) 2.75 in. (69.9 mm) CAN Port 2 3.25 in. (82.6 mm) CAN Port 1 .
GCA mod- ules. See Related Manuals on page 2. Port 6 14. Refer to the E-Flo SP Software Instructions manual for details regarding the fieldbus pinout setup and to perform the setup procedure to configure the field- bus.
Kits and Accessories Pump Stand Frame, 253692 3. Refer to the Pump Stand Mounting Hole Diagram on page 34 and use the holes in the base of the stand as a guide to drill holes for 1/2 in. (13 mm) anchors.
Light Tower Kit, 255468 For D200s, D200, and D60 single supply systems. See the Light Tower Kit manual for more information. I/O Cable, 122029 See the E-Flo SP Software Instructions manual for setup and pin out information. Part Description Length 15.0 m...
Dimensions Floor Stand Mounting Hole Diagram 14.0 in. (355.6 mm) 9/16 in. Diameter 14.0 in. 11.0 in. (355.6 mm) (279.4 mm) 17.0 in. (431.8 mm) . 31: Floor Stand Mounting Holes Electric Driver Mounting Hole Pattern . 32: Electric Driver Mounting Holes 6.2 in.
Pump Performance Pump Performance Calculate Fluid Outlet Pressure To calculate fluid outlet pressure (psi/MPa/bar) at a spe- cific fluid flow (gpm/lpm) and electrical power (W), use the following instructions and pump data chart. 1. Refer to the desired flow along the bottom of the chart.
255 bar, 25.5 MPa 290cc Dura-Flo - CS 2800 psi 193 bar, 19.3 MPa Motor Oil Specification Graco part no. 16W645, ISO220 silicone-free synthetic EP gear oil*** Capacity 1.5 quarts 1.4 liters Notes Full load amps with all devices operating at maximum capabilities.
California Proposition 65 E-Flo SP Electric Pumps Metric Wetted Materials See separate pump manual in Related Manuals on page 2 Check-Mate - All See separate pump manual in Related Manuals on page 2 Dura-Flo 115, 145, 180, 220, 290 CS...
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.
Need help?
Do you have a question about the E-Flo SP and is the answer not in the manual?
Questions and answers