Reference Information for the fruinfoset Command

This command allows modification of data that is specific to a FRU. It must be entered through a CLI session (telnet or serial)
to the active CP card, using root access.
Synopsis
fruinfoset FRU_ID number
Availability
Factory or root only
Description
This command allows the setting of four externally modifiable fields in the header associated with each FRU. After the
new data is written, the final contents of the fields are printed. No other fields can be modified.
Some FRUs may not contain customer data or may not be programmable, in which case an error message displays.
Operands
Two operands are required: FRU ID and number.
FRU ID
Type of FRU:
number
Physical slot or unit number for which the information will be input
(for chassis information enter "chassis 1", for WWN card information enter "chassis 2")
Usage
The modifiable fields and their maximum field sizes are as follows:
Field Name
ID
PN (part number)
SN (OEM serial number)
RV (revision code)
Chassis SN (serial number)
These fields may not display for all FRUs. For each field, the existing value is displayed followed by a ">" prompt for the
new value. If more than the allowed number of characters are entered, the extra characters at the end are ignored and a
warning message displays. Leading blanks are also ignored.
If the parameter "chassis 1" is entered after the command, an additional prompt for the chassis serial number displays,
"Chassis SN:". The maximum field size is 12 characters, and the usage rules are the same as for other values. The
chassisshow command displays the chassis serial number as the "Factory Serial Num" under Chassis/WWN: unit 1.
SilkWorm 12000 WWN Card Replacement Procedure
slot (port card or CP card in a slot)
fan (blower assembly)
ps (power supply)
chassis (chassis or WWN card)
Max # Characters
10 characters
20 characters
20 characters
4 characters
12 characters (this field only displays when the "chassis 1" parameter is used)