Astronics Max-Viz 1500 Information Manual

Enhanced vision system

Advertisement

Information Manual
Max-Viz 1500 Enhanced Vision System
Astronics Max-Viz
Max-Viz 1500
3091-00019 Rev M

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Max-Viz 1500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Astronics Max-Viz 1500

  • Page 1 Information Manual Max-Viz 1500 Enhanced Vision System Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 2 Astronics Max-Viz 11241 SE Highway 212 Clackamas, Oregon 97015 USA This product is protected by patents and patents pending. Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 3 Images, all mentions of NUC interval are now 4 minutes and fixed several typos. 12/08/2010 Updated the Max-Viz logo on page 1, Updated the address on this manual, Updated Warranty Form and Customer Service form to latest revisions. Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 4 Window and added warning about the use of Corrosion X to sections 6.2 and 6.3. 03/31/16 Updated company mailing address. Changed Product name to Max-Viz 1500. Updated font style and spacing for Table of Contents 8/29/16 Changed the recommended coax cable to PIC V76261.
  • Page 5: Table Of Contents

    Non-Uniformity Correction (NUC) ..................15 6.9. Video Signal Interruption/ Improper Display Settings ............15 7. Max-Viz, Inc. Contact Information ..................15 Appendix A ..........................16 Warranty Registration Form ....................23 Customer Service Request Form / Return Material Authorization ..........24 Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 6: Introduction

    Max-Viz 1500 Enhanced Vision System (EVS) product. 2. SYSTEM DESCRIPTION The Max-Viz 1500 is comprised of two Line Replaceable Units (LRUs) designed to provide the flight crew with enhanced visual awareness of terrain and potential obstacles in the aircraft’s forward field of view.
  • Page 7: Physical Characteristics

    It is also provided to assist in non-certified aircraft installations. The Max-Viz 1500 is limited to a max altitude of 55,000 feet and a operating temperature of -55C to +70C. The +28 Vdc supply to the Power Supply should be routed through a suitably labeled circuit breaker.
  • Page 8: Interface Connections

    22 AWG Shielded TP6 RS 232 + 22 AWG Shielded TP7 RS 232 RTN 22 AWG Shielded TP7 RS 232 -- 22 AWG Shielded TP8 RS 232 RTN 22 AWG Shielded TP8 Chassis/Shields 22 AWG Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 9 NUC cycles are inhibited until the input goes back to 0 (< 2 volts). c. On transition from 28 to 0 volts (< 2 volts), one NUC cycle occurs and then further NUC cycles automatically occur at programmed intervals. Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 10 There should be no cable loss limitations for RG-179 if less than 100 feet. If multiple displays are to be connected, the video signal from the Max-Viz 1500 should go directly to a multiple output amplified video buffer with as short of a run as feasible...
  • Page 11: Recommended Installation Procedure

    Do not connect the 28 Vdc power connector to the Power Supply. Switch “ON” the circuit breaker and the “ON/OFF” switch to the Max-Viz 1500 system. Verify and measure the +28 VDC between pins 1 and 2 and pins 3 and 4 of the Power Supply connector.
  • Page 12: Maintenance

    The type certificate holder will contact Max-Viz as necessary. If it is not a certified installation, the dealer will contact Max-Viz. If it is determined the Max-Viz 1500 must be returned for service or maintenance, Max- Viz will issue a Return Material Authorization (RMA). Fill out Max-Viz Customer Service Request Form located at the end of this manual and submit it to receive a RMA.
  • Page 13: Warnings, Cautions, And Guidance

    6. WARNINGS, CAUTIONS, AND GUIDANCE 6.1. Electromagnetic Interference The Max-Viz 1500 system is qualified (RTCA/DO-160) to operate in normal aircraft EMI When installing the system, be sure that the Sensor window is environments. not installed in close proximity to high power EMI transmitters, such as transponders.
  • Page 14: Ice Effects And Body Heaters

    The Sensor is sealed at the factory and filled with nitrogen to eliminate moisture. If the Do not open the Sensor during system Sensor is opened, the nitrogen will be lost. installation or maintenance, warranty is void if opened. Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 15: Non-Uniformity Correction (Nuc)

    Following initial power-up of the system, always adjust brightness and white. contrast settings to obtain the best image. 7. MAX-VIZ, INC. CONTACT INFORMATION Astronics Max-Viz 11241 SE Highway 212 Clackamas, OR 97015 USA Office: (503) 968-3036 Email: customer.servicemv@max-viz.com Website: www.max-viz.com Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 16 APPENDIX A A-1 “Interface Drawing – EVS – 1500”: 952500015 Rev. 3 A-2 “Cable Assy – EVS - 1500 Sensor Interconnect”: 955000016 Rev. 1 Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 17 Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 18 Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 19 Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 20 Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 21 Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 22 Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 23: Warranty Registration Form

    Operator (if other than owner): Aircraft Information Manufacturer: Reg. No: Model No.: Serial No: Warranty Start Aircraft Date: Hours: (mm/dd/yy) Installation Date: Aircraft (mm/dd/yy) Hours: Max-Viz Product Information Model No: Serial No: Model No: Serial No: Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...
  • Page 24: Customer Service Request Form / Return Material Authorization

    Operator (if other than owner): Aircraft Information Manufacturer Reg. No. Model No. Serial No. Aircraft Hours Description of Service EVS Model No. Serial No. Date: Description of Service Requested or Problem to be Fixed: Astronics Max-Viz Max-Viz 1500 3091-00019 Rev M...

Table of Contents