Symbols Please read first The following symbols are used in the operating This operating manual provides important informa- tion on the handling of the unit. It is an integral part of manual. They have the following meaning: the product and must be stored so that it is accessi- ble in the immediate vicinity of the unit.
Intended use EC conformity The unit may be used only for the intended The unit bears the CE mark of conformity. purpose. This means - only in combination with the EC declaration of conformity manufacturer’s hydraulic module or hydraulic tower (see manual HMD, HTD).
Constituents (such as ammonia, sulphur, ● Germany: www.alpha-innotec.de chlorine, salt, sewage gases, flue gases…) ● www.alpha-innotec.com can cause damage to the heat pump, which...
Disposal Area of utilisation When decommissioning the unit, always comply Taking into consideration the ambient conditions, limits with applicable laws, directives and standards for of application and the applicable regulations, every the recovery, recycling and disposal of materials and heat pump can be utilised in new or existing heating components of cooling units.
Cleaning and flushing of unit The components of the heating circuit and the heat source (valves, expansion vessels, circulating pumps, components filters, dirt traps) should be inspected and cleaned as necessary - however, at least once a year - by qualified CAUTION! personnel (heating or cooling system fitters).
Overview “Technical data / scope of delivery”, ATTENTION “Sound” section and “Sound level” overview. Do not tilt the unit more than a maximum of 45° (in any direction). Installation location Preparing the installation, together ATTENTION with the wall penetration Install the unit only outside buildings. To connect the outdoor unit with the indoor part (hydraulic module), an opening must be provided for Dimensional drawing, installation plans and...
Condensate drain NOTE If the wall penetration is not used, the bus ca- The condensate from the air must be discharged frost- ble must be laid through a separate conduit, free through a plastic condensate pipe with a minimum separated from the other cables. diameter of 40 mm.
NOTE ATTENTION If the condensate pipe is not laid to the in- When installing the connections, always se- side, the openings in the wall penetration at cure the connections on the unit against the front and back must be closed off with the twisting, to prevent damage to the copper plugs supplied.
During installation and while carrying out Minimum size 60l. electrical work, comply with the relevant Only one separating tank integration (vapour diffusion EN‑, VDE and/or local safety regulations. insulated) is allowed for the LWD 50A/RX and LWD Comply with technical connection 70A/RX.
trouble-free running of the systems is achieved with NOTE so-called low-salt operation. The heat exchanger surface of the domes- VDI 2035 Part I gives important information and tic hot water tank must be dimensioned so recommendations regarding scaling and its prevention that the heating capacity of the heat pump is in heating and domestic hot water heating systems.
Page 14
Water softening to VDI 2035 – Part I On the safe side with low-salt operation If the water is softened before the heating is filled, in accordance with the VDI 2035 guidelines, no scale The problems listed above do not occur at all with can form.
Commissioning Insulating the hydraulic connections WARNING! Insulate the piping of the heating circuit and the The unit may only be started up if the condensate pipe in the outdoor area so that they are façade / facing panels are closed. frost-proof, vapour-diffusion tight and UV resistant.
Withdrawal from service The heat pump system is commissioned by customer service personnel authorised by the It is particularly important that the technician manufacturer. There is a fee for starting up! responsible for the withdrawal from service work is familiar with all details of the disposal equipment. We recommend that all refrigerant be recovered.
Markings Units must be appropriately marked or labelled so that it is clear to all that they have been withdrawn from service and the refrigerant has been removed. This marking must be dated and signed. Ensure that information regarding flammable refrigerant is attached to the units.
Technical data / scope of delivery Gerätebezeichnung Heat pump type Brine/water ı Air/water ı Water/water • applicable ı — not applicable Installation location Indoors ı Outdoors • applicable ı — not applicable Conformity Performance data Heating capacity/COP at "kW ı … A7/W35 Standard point acc.
Page 20
Technical data / scope of delivery Gerätebezeichnung Heat pump type Brine/water ı Air/water ı Water/water • applicable ı — not applicable Installation location Indoors ı Outdoors • applicable ı — not applicable Conformity Performance data Heating capacity/COP heat optimised at A7/W35 Standard point as per EN14511 1 compressor...
Dimensional drawings LWD 50A(RX) – LWD 70A(RX), LWD 90A UK819392a All dimensions in mm. Front view Side view Section (floor slab) Heating water flow G1" DIN ISO 228 flat gasket. Heating water return flow G1" DIN ISO 228 flat gasket.
LWD 50A(RX) – LWD 70A(RX) Installation protection areas LWD 90A 2,3m 0,5m 0,5m 3,3m Abbildung: Sicherheitsabstände zur Wärmepumpe Legende: DE819401 Legend: DE819401 Technische Änderungen vorbehalten Heat pump Wärmepumpe Protection area Schutzbereich to the floor bis zum Boden Doors, windows, light wells, etc. into the building Türen, Fenster, Lichtschächte, usw.
Wall bracket installation plan LWD 50A(RX) – LWD 70A(RX) Wall feedthrough LWD 90A 1320 FS >800 FS >800 Legende: 819393-1c Technische Änderungen vorbehalten. Legend: 819393-1c Alle Maße in mm. All dimensions in mm. Variante 1 Variant 1“ Vorderansicht Front view...
LWD 50A(RX) – LWD 70A(RX) Floor bracket installation plan Hydraulic connection pipe LWD 90A 1320 FS >800 FS >800 Legend: 819393-2c Legende: 819393-2c All dimensions in mm. Technische Änderungen vorbehalten. Alle Maße in mm. Variant 2“ Variante 2 Front view...
Floor bracket installation plan LWD 50A(RX) – LWD 70A(RX) Wall feedthrough LWD 90A 1320 FS >800 FS >800 Legende: 819393-2c Technische Änderungen vorbehalten. Legend: 819393-3c Alle Maße in mm. All dimensions in mm. Variant 3“ Variante 3 Vorderansicht Front view...
LWD 50A(RX) – LWD 70A(RX) Floor bracket installation plan Hydraulic connection pipe LWD 90A 1320 FS >800 FS >800 Legend: 819393-4c Legende: 819393-4c All dimensions in mm. Technische Änderungen vorbehalten. Alle Maße in mm. Variant 4“ Variante 4 Front view...
Drilling pattern for wall bracket LWD 50A(RX) – LWD 70A(RX) Wall feedthrough LWD 90A Ø12 Legende: 819393-5c Technische Änderungen vorbehalten. Alle Maße in mm. BB1 Bohrbild für Wandkonsole (Zubehör) an Befestigungswand zu V1 Legend: 819393-5c Vorderansicht We reserve the right to make changes without Note Detailansicht Wandbefestigung All dimensions in mm.
LWD 50A(RX) – LWD 70A(RX) Drilling pattern for wall bracket Hydraulic connection pipe LWD 90A Ø12 Legende: 819393-6c Technische Änderungen vorbehalten. Alle Maße in mm. BB2 Bohrbild für Wandkonsole (Zubehör) an Befestigungswand zu V2 Vorderansicht Detailansicht Wandbefestigung Legend: 819393-6c Gerätekontur All dimensions in mm.
View of foundation V3 LWD 50A(RX) – LWD 70A(RX) Wall feedthrough LWD 90A 1320 1190 >1300 1320 Legend: 819393-7c Legende: 819393-7c All dimensions in mm. Technische Änderungen vorbehalten. Alle Maße in mm. View of foundation for V3 Front view FU3 Ansicht Fundament zu V3...
LWD 50A(RX) – LWD 70A(RX) View of foundation V4 Hydraulic connection pipe LWD 90A 1320 >1300 1190 X (1 : 5) Ø12 Legende: 819393-8c Technische Änderungen vorbehalten. Legend: 819393-8c Alle Maße in mm. All dimensions in mm. Detail view of floor mounting“...
Minimum clearances LWD 50A(RX) – LWD 70A(RX) LWD 90A >3000 Legende: 819393-10c Technische Änderungen vorbehalten. Alle Maße in mm. FW2 Funktionsnotwendige Mindestabstände Draufsicht Fertigaußenfassade Legend: 819393-10c Luftrichtung All dimensions in mm. Mindestabstände Functionally necessary minimum spacings Plan view Finished outer façade Air direction >...
LWD 50A(RX) – LWD 70A(RX) Outside connection of LWD 90A condensate pipe Legende: 819400-1 Technische Änderungen vorbehalten. Aufstellungshinweise für Anschluß der Kondensatleitung außerhalb des Gebäudes. Kiesschicht zur Aufnahme von bis zu 50l Kondenswasser pro Tag als Pufferzone zum versickern. Kondensatablaufrohr DN 40...
Inside connection of LWD 50A(RX) – LWD 70A(RX) condensate pipe LWD 90A Legende: 819400-2 Technische Änerungen vorbehalten. Aufstellungshinweise für Anschluß der Kondensatleitung innerhalb des Gebäudes. Wichtig: Beim Anschluss der Kondensatleitung innerhalb eines Gebäudes muss ein Syphon eingebaut werden, der mit dem Abflussrohr gasdicht abschließt (siehe Abbildung 2a).
LWD 50A(RX) – LWD 70A(RX), LWD 90A Circuit diagram 1/2 Subject to change without notice | 83053500lUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 43
Circuit diagram 2/2 LWD 50A(RX) – LWD 70A(RX), LWD 90A DI14 OUT1 OUT3 OUT4 OUT5 Green Yellow white Brown AIN1 AIN2 Subject to change without notice | 83053500lUK – Translation of the original operating manual | ait-deutschland GmbH...
Page 44
GmbH Industriestrasse 3 95359 Kasendorf, Germany E info@alpha-innotec.de W www.alpha-innotec.de alpha innotec – an ait-deutschland GmbH brand...